background image

Page 12

Go Online or Complete and Return

We know that registering any of your recently purchased products is not the 

first thing on your mind- but it is very important to both of us. Not all warranties 

are alike and Peak Scientific stand out against other gas suppliers as we offer 

a comprehensive on-site warranty.  This means that in the very unlikely case 

that your gas generator develops a fault we have rapid support teams on-hand 

throughout the globe who are able to come to your lab and get you back up 

and running in no time.

Register for your 

comprehensive 12 month on-site warranty 

with ease online at 

www.peakscientific.com/protected.

Alternatively, you can send the completed form to Peak Scientific by post or 
email at [email protected].

Important!

You have 

1 month to register

 your Peak Scientific product from the date of 

installation. Once registered the warranty will be honoured for a period of 12 

months. If you wish to defer the installation of your generator, you must notify 

Peak Scientific immediately by emailing 

[email protected]

 For 

generators that remain unregistered after 1 month from the shipment date, the 

warranty will be considered active from the date of factory dispatch.

Go Online or Complete and Return

You can register for your 

FREE 12 month Warranty 

with ease online at 

www.peakscientific/protected

.

Alternatively, you can send the completed form to Peak Scientific by post or 
email at 

[email protected]

.

Product Warranty Registration

Contact name

Email address

Company

Address

City/town

Postcode

Country

Telephone

Generator serial #

Model type

Installation date

Do you still use an 

alternative gas solution i.e. 

cylinders or bulk liquid?

Yes                 No

What gas requirements do 

you have in your lab?

Hydrogen             Nitrogen            Zero Air

Extend your cover with

Peak Scientific offer comprehensive gas generator after sales support packages.  

Peak [Protected] aftercare support can guarantee an on-site response within 

72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time 

fix rate.  See our enclosed Peak [Protected] leaflet for further information.

Important!

You have 1 month to register your Peak Scientific product from the date of installation. Once registered 

the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your 

generator, you must notify Peak Scientific immediately by emailing [email protected]

For generators that remain unregistered after 1 month from the shipment date, the warranty will be 

considered active from the date of factory dispatch.

* Complete Plan only

Содержание 3300671

Страница 1: ...Solaris XE Installation Guide Copyright Peak Scientific Instruments Ltd 2021 Solaris XE Installation Guide Rev 3 PN IG 0023 RSID 2301 EN 24 08 2021...

Страница 2: ...o be used as a step by step quick start guide to facilitate installation and configuration Please visit www peakscientific com downloads to download the full User Manual for your gas generator Thank y...

Страница 3: ...notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause damage to the Generator or the Application Do not pr...

Страница 4: ...029 x1 EU Mains Cable C13 04 1038 x1 US Mains Cable C13 5 15 04 1039 x2 6mm Push Fit Elbow Fitting 02 4331 x3m 6mm Teflon Tubing 00 1302 Fittings Kit x1 JP Mains Cable C13 100V 04 1006 x1 2 5mm Hex Ke...

Страница 5: ...a two man lift Safe lifting practices are advised 1 2 The generator can be wall mounted If you do not wish to wall mount your generator proceed to step 5 The measurements for the 4 mounting holes are...

Страница 6: ...he holes drilled in your desired location fit the 4x No 8 Wall Plug 00 4076 and 4x No 8 Screw 00 4075 to the wall and mount your generator onto them Note If mounting the generator on the wall the gene...

Страница 7: ...ports 6 Attach the some of the supplied 6mm Teflon Tubing 00 1302 to the AIR IN port and connect this to your house air Attach the remainder of the supplied 6mm Teflon Tubing 00 1302 to the NITROGEN p...

Страница 8: ...electrical supply CAUTION UK EU US 230V Select the appropriate mains cable from the fittings kit and plug the IEC 60320 C13 cable into the mains input at the rear of the generator Please note both 110...

Страница 9: ...Page 9 10 9 Press the POWER switch located at the rear of the generator The LEDs on the front of the generator should now illuminate YELLOW until the unit reaches operating pressure YELLOW YELLOW...

Страница 10: ...operational and ready to supply gas on demand to your instrument Turn the air supply to the generator on the LEDs will illuminate GREEN to indicate when the generator has reached an internal pressure...

Страница 11: ...ended Extended periods at extremes can have a detrimental effect on the operation and life of the Generator Please familiarise yourself with the full User Manual available at www peakscientific com do...

Страница 12: ...e date of factory dispatch Go Online or Complete and Return You can register for your FREE 12 month Warranty with ease online at www peakscientific protected Alternatively you can send the completed f...

Страница 13: ...Page 13 Copyright Peak Scientific Instruments Ltd 2021 Solaris XE Installation Guide Rev 3 PN IG 0023 RSID 2301 EN 24 08 2021...

Страница 14: ...Page 14...

Страница 15: ...Page 15...

Страница 16: ...nd the world This allows us to provide an industry leading rapid response service to our customers With Peak Protected your laboratory s productivity becomes our top priority To discuss Peak Protected...

Отзывы: