REPLACING THE FUSES 

WARNING

:  To  avoid  electric  shock,  disconnect  the  test 

leads  from  any  source  of  voltage  before  removing  the 
fuse/battery cover. 

1.    Disconnect  the  test  leads  from  the  meter  and  any  item 

under test. 

2.    Remove  the  fuse/battery  cover  by  loosening  the  two 

screws using a Phillips head screwdriver. 

3.    Remove the old fuse from its holder by gently pulling it   

out.   

3.  Install the new fuse into the holder. 
4.  Always use a fuse of the proper size and value     

(0.8A/250V  fast  blow  for  the  600mA  range,  10A/250V 
fast blow for the 10A range). 

5.  Replace the battery cover and secure with two screws. 
 

WARNING

:  To  avoid  electric  shock,  do  not  operate  your 

meter until the fuse door is in place and fastened securely. 
 
 

Warranty

                                                                                   

This  PDI  product  is  warrantied  to  be  free  from  defects  in 
materials  and  workmanship  for  a  period  of  two  (2)  years 
from  the  verified  date  of  purchase.  During  this  warranty 
period, PDI will either repair or replace the defective unit, at 
PDI’s  discretion.  A  purchase  receipt  or  other  acceptable 
form  of  proof  of  original  purchase  date  will  be  required 
before  any  warranty  processes  begin.  PDI  warrants  all 
authorized  repairs  with  a  six  (6)  month  limited  warranty.   

Содержание DM-918

Страница 1: ...DM 918 OPERATIONS MANUAL AUTORANGING MULTIMETER...

Страница 2: ...ding by using dry clothing rubber soled shoes rubber mats or any approved insulating material Turn off power to the circuit under test before cutting unsoldering or breaking the circuit Small amounts...

Страница 3: ...N symbol indicates a potentially hazardous situation which if not avoided may result damage to the product This symbol advises the user that the terminal s so marked must not be connected to a circuit...

Страница 4: ...ve Input Jack for 10A DC or AC measurements 6 Measuring MODE selection button 7 Range button 8 Hold Backlight button 9 MAX Min Hold button DISPLAY DESCRIPTION Continuity Low Battery Diode HOLD Data Ho...

Страница 5: ...drops below the operating level Measurement rate 3 times per second nominal Auto power off Meter automatically shuts down after approx 15 minutes of inactivity Operating environment 0 C to 50 C 32 F t...

Страница 6: ...acy 6 000V 1mV 1 of rdg 3 dgts 60 00V 10mV 1 2 of rdg 3 dgts 600 0V 100mV 600 0V 1V Input Impedance 10M Frequency Range 50 to 400Hz Maximum Input 600V DC or 600V AC RMS DC Current Autoranging for A an...

Страница 7: ...ut 600mA DC or 600mA AC RMS on A mA ranges 10A DC or AC RMS on 10A range Resistance Autoranging Range Resolution Accuracy 6 0 1 1 2 of rdg 4 dgts 6 1 1 0 of rdg 2 dgts 6 10 1 5 of rdg 2 dgts 6 100 6 1...

Страница 8: ...g 4 dgts Sensitivity 8V RMS Overload protection 250V DC or AC RMS Duty Cycle Range Resolution Accuracy 0 1 99 9 0 1 1 2 of rdg 2 dgts Pulse width 100us 100ms Frequency width 5Hz 150kHz Sensitivity 8V...

Страница 9: ...1 ALWAYS turn the function dial to the OFF position when the meter is not in use This meter has an Auto Power Off function that automatically shuts the meter OFF after 15 minutes of inactivity 2 If OL...

Страница 10: ...ange for the measurements being made and is generally the best mode for most measurements For measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE...

Страница 11: ...ton DC VOLTAGE MEASUREMENTS CAUTION Do not measure DC voltages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur that can damage the meter 1 Set the function dial to...

Страница 12: ...ages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur that can damage the meter 1 Set the function dial to the V position and press the MODE key to select the AC mo...

Страница 13: ...n appears on the left side of the display 6 Remove power from the circuit under test then open up the circuit at the point where you wish to measure current 7 Touch the black test probe tip to the neg...

Страница 14: ...uit at the point where you wish to measure current 7 Touch the black test probe tip to the negative side of the circuit and the red test probe tip to the positive side of the circuit 8 Apply power to...

Страница 15: ...into the positive jack 3 Touch the test probe tips to either side of the circuit or part under test It is best to disconnect one side of the part under test so the rest of the circuit will not interf...

Страница 16: ...t lead into the negative COM jack and the red test lead into the positive jack 3 Touch the test probe tips to the diode or semiconductor junction you wish to test Note the meter reading 4 Reverse the...

Страница 17: ...before making a temperature measurement 1 Set the function dial to the C F position and press the MODE button to select between C Celsius and F Fahrenheit 2 Insert the Temperature Probe s into the Te...

Страница 18: ...screwdriver 3 Remove old battery and insert new battery into battery holder observing correct polarity Replace battery cover and secure with two screws 4 Properly dispose of old battery WARNING To av...

Страница 19: ...the 600mA range 10A 250V fast blow for the 10A range 5 Replace the battery cover and secure with two screws WARNING To avoid electric shock do not operate your meter until the fuse door is in place a...

Страница 20: ...your PDI product at www PDImeters com NOTE Online product registration is required for all warranty claims All warranty claims must have a Return Goods Authorization assigned from PDI in order to beg...

Отзывы: