background image

 

1.   Set the rotary function dial to the 

CAP

” position. 

2.  Insert the black test lead banana plug into the negative 

(

COM

) jack. Insert the red test lead banana plug into the 

positive (

V

) jack. 

3.   Touch the test leads to the capacitor to be tested. 
4.   Read the capacitance value in the display 
 

Frequency/Duty Cycle Measurements (electronic) 

1. 

Set the rotary function switch to “

V

” position. 

2.  Select ACV with the 

MODE

 button 

3.  Press the 

Hz%

 

button to indicate “

Hz

” in the display. 

4.  Insert the black test lead banana plug into the negative 

COM

 jack and the red test lead banana plug into the 

positive 

Hz

 jack. 

5.  Touch the test probe tips to the circuit under test. 
6.  Read the frequency on the display. 
7.  Press the 

Hz%

 

button again to indicate “

%

” on the 

display. Read the 

%

 of duty cycle on the display. 

 

Temperature Measurements 

WARNING: 

To avoid electric shock, disconnect both test 

probes from any source of voltage before making a 
temperature measurement. 

1.   Set the rotary function dial to 

TEMP

2.   Insert the K-Type adapter into the negative 

COM

 

and the 

V

 jacks, making sure to observe the correct 

polarity. 

3.   Select 

C or 

F with the 

MODE

 button. 

4.   Touch the Temperature Probe head to the part whose  

temperature you wish to measure. Keep the probe 
touching the part under test until the reading stabilizes 
(about 30 seconds). 

5.    Read the temperature in the display. The digital reading   

will indicate the proper decimal point and value. 

WARNING: 

To avoid electric shock, be sure the 

thermocouple has been removed before changing to 
another measurement function 

Содержание CM-220

Страница 1: ...CM 220 True RMS AC CLAMP METER INSTRUCTION MANUAL...

Страница 2: ...TES Do not exceed the maximum allowable input range of any function Do not apply voltage to meter when resistance function is selected Set the function switch to OFF when the meter is not in use WARNI...

Страница 3: ...d Remove the battery if the meter is to be stored for long periods Always discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests Voltag...

Страница 4: ...lect button 11 LCD display 12 COM input jack 13 V CAP TEMP Hz input jack 14 Battery Cover 1 AC DC AC alternating current and DC direct currrent 2 Minus sign 3 8 8 8 8 6000 count 0 to 5999 measurement...

Страница 5: ...5 2 digits 60 00 VDC 600 0 VDC AC Voltage 50 400Hz 6 000 VAC 1 8 8 digits 60 00 VAC 600 0 VAC Resistance 600 0 1 0 4 digits K 1 5 2 digits K K M 2 5 3 digits M 3 5 5 digits Capacitance 40 00nF 4 0 re...

Страница 6: ...50 400Hz VAC Operating Temperature 41 to 104 o F 5 to 40 o C Storage Temperature 4 to 140 o F 20 to 60 o C Operating Humidity Max 80 up to 87 F 31 C decreasing linearly to 50 at 104 F 40 C Storage Hu...

Страница 7: ...he 1000A or 600A range 2 If the range of the measured is not known select the higher range first then move to the lower range if necessary 3 Press the trigger to open jaw Fully enclose one conductor t...

Страница 8: ...jack and the red test lead banana plug into the positive diode jack 2 Turn the rotary dial to the position 3 Press the MODE button until appears in the display 4 Touch the test probes to the diode un...

Страница 9: ...uency on the display 7 Press the Hz button again to indicate on the display Read the of duty cycle on the display Temperature Measurements WARNING To avoid electric shock disconnect both test probes f...

Страница 10: ...th high sensitivity Static electricity or other sources of energy may randomly trip the sensor This is normal operation MODE BUTTON To select between DC ACV Diode Continuity CAP C F MIN MAX Recording...

Страница 11: ...de and is generally the best mode for most measurements For measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE button The Auto Range display ind...

Страница 12: ...either repair or replace the defective unit at PDI s discretion A purchase receipt or other acceptable form of proof of original purchase date will be required before any warranty processes begin PDI...

Страница 13: ...13...

Отзывы: