16
WARNING:
•
Do not measure voltage above 600V; otherwise the instrument might get
damaged and there is a risk of injury.
•
If the display shows “OL”, disconnect the probes’ tips from the measuring
circuit immediately (Overload)
•
Pay special attention to safety when measuring high voltage to avoid electric
shock or personal injury.
•
Always test known voltage before using the device, in order to ensure that
the device functions properly.
•
Do not touch the bare tips of the probes; when measuring is finished, always
remove the probes from the measuring object and the device.
Caution:
High impedance voltage measurement: 10M
Ω
Low impedance voltage measurement: 300k
Ω
Note: When the measured voltage is greater than 80V, the orange backlight of the
display will light up.