5  Measuring 

5.1  Switch between measurement parameters 

The anemometer shows 2 different measurement parameters at the same time. By default, these 
parameters are air temperature on the lower display and flow velocity on the upper display. To change 
the displayed parameters, use the Up and Down buttons. 
By pressing Up, you can switch between flow velocity and relative air humidity on the upper display. 
When pressing Down, you can switch between air temperature, volume flow, wet bulb temperature and 
dew point temperature on the lower display. 

5.2  Volume flow measurements 

Before measuring  the volume flow,  you  have  to  enter  the  dimensions  of the  cross-sectional  area  in the 
setup menu (see chapter 7.1.2 for more information).  
After AREA setting is completed, press the down button to switch the display to air volume flow and the 
measured air volume flow will be displayed on the lower LCD. 
 
You  can  also  measure  the  volume  flow  with  an  airflow  cone.  To  do  so,  just  attach  one  of  the  optional 
cones to the meter. The anemometer detects the cone automatically and shows a cone indication on the 
display. After that, the device will calculate the volume flow. 
 

Note: Make sure the airflow cone is well mounted and locked tight. 

 

5.3  Measuring relative humidity 

The capacitive humidity sensor is built in the centre of the vane. 
Press the Up button to show the relative air humidity on the upper display. 
It is also possible to set an offset value. See chapter 7.1.3 for more information. 
 

6  Functions 

6.1  Data Hold 

In normal measuring mode, press the Hold button to freeze the current reading on the LCD. 

A “HOLD” 

icon appears on the display. To unfreeze the reading, just press the press the Hold button again. 
 

6.2  MIN/MAX 

In normal measuring mode, press and hold the Hold button for 3 seconds. The display now shows the 
MIN value, as well as a “MIN” indication. 
Press and hold the button again, 

to view the MAX value. The display also shows a “MAX” indication. 

Press and hold the Hold button once again to return to normal measuring mode. 
 

Note: While viewing the MIN and MAX values, you can use the Up and Down buttons to switch between 
the different parameters. 

 

 

Содержание PCE-VA 20

Страница 1: ...ruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce i...

Страница 2: ...unctions 7 6 1 Data Hold 7 6 2 MIN MAX 7 6 3 Averaging 8 6 3 1 Multi point average 8 6 3 2 Time average 8 6 4 Auto power off function 8 7 SETUP 9 7 1 1 P1 0 Unit selection 9 7 1 2 P2 0 AREA Size 9 7 1...

Страница 3: ...be used by qualified personnel and repaired by PCE Instruments personnel There is no warranty of damages or injuries caused by non observance of the manual Don t use the device with wet hands Do not u...

Страница 4: ...measured value 0 3 m s when above 20 m s Temperature 0 6 C Relative humidity 3 at 25 C else 5 Technical Data Fan diameter 10 cm Fan anemometer dimensions 269 x 160 x 51 mm Airflow cone dimensions Rou...

Страница 5: ...ure dew point temperature 4 1 Display Display indication Meaning HOLD Freeze the current display AVG Averaging MAX MIN Highest and lowest values Low battery warning m s fpm Flow velocity display units...

Страница 6: ...MIN and MAX values In average mode press to record data or start timed recording In setup mode press to enter data settings Switches to upper display Long press to go into average mode In average mode...

Страница 7: ...ttach one of the optional cones to the meter The anemometer detects the cone automatically and shows a cone indication on the display After that the device will calculate the volume flow Note Make sur...

Страница 8: ...e current reading Press the Hold button to start recording The timer on the upper display starts counting Press the Up button to stop and calculate the timed average You can see the duration on the up...

Страница 9: ...nsions of the cross sectional area for volume flow measurements Press the Hold button to enter the area setting The lower display now shows 99999 with the first digit flashing Press the Up button to c...

Страница 10: ...fan anemometer for repair E03 Temperature is above measuring range Acclimatize the fan anemometer at room temperature for 30 minutes If E02 is still displayed return the fan anemometer for repair E31...

Страница 11: ...s above range Take measurements within range If E03 is still displayed return the fan anemometer for repair 9 2 5 Volume Flow Error code Error Remedial action E03 Value is above display range Check en...

Страница 12: ...contact PCE Instruments 10 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 10 2...

Отзывы: