z
Frequency Response: 40Hz ~ 400Hz
z
Displays effective value of sine wave (mean value response).
ii.
Under Scope mode
z
The specification is same as
Bi Under Multimeter mode
.
z
On the top right corner of the display shows the accuracy of the frequency which is around ±2%.
When the LCD displays 1-10 period waveform, the reading is valid, otherwise the Meter displays “ ———
—“
C. DC Current
Range ResolutionAccuracy
Overload Protection
400
μ
A 0.1
μ
A
±(1%+8)
0.5A, 250V, fast type fuse,
ø5×20mm
4000
μ
A 1
μ
A
40mA 10
μ
A
±(1.2%+8)
400mA 100
μ
A
4A 1mA
±(1.5%+8)
10A, 250V, fast type fuse,
ø5×20mm.
(Continuous measurement
≤
10
seconds and interval more than 15
minutes.)
10A 10mA
D. AC Current
i.
Under Multimeter mode
Range Resolution Accuracy Overload
Protection
400
μ
A 0.1
μ
A
±(1.5%+8)
0.5A, 250V, fast type fuse, ø5×20mm
4000
μ
A
1
μ
A
40mA 10
μ
A
±(2%+8)
400mA
100
μ
A
4A 1mA
±(2.5%+5)
10A, 250V, fast type fuse, ø5×20mm
(Continuous measurement
≤
10
seconds and interval more than 15
minutes.)
10A 10mA
Remarks:
z
Frequency Response: 40Hz~400Hz.
z
Displays effective value of sine wave (mean value response).
ii.
Under Scope mode
z
The specification is same as
Di Under Multimeter mode
.
z
On the top right corner of the display shows the accuracy of the frequency which is around ±2%.