2) After setting the upper text to "bASI" or "Euro", pressing the "Enter Button" (4-4) will save the setting 
function as default. 
 

Auto power OFF 

When the lower display shows "PoFF", 
1) use the "

▲ Button" (4-5) or the "▼ Button" (4-6) to set the upper value to "yES" or "no". 

yES - Auto Power Off enabled 
no - Auto Power Off disabled 
3) After selecting "yES" or "no", press the "Enter Button" (4-4) to save the default setting. 
 

Switch beeper sound ON/OFF 

1) Use the "▲ Button" (4-5) or the "▼ Button" (4-6) to select "yES" or "no". 
yES - meter's beep sound will be ON by default 
no - meter's beep sound will be OFF by default 
3) After selecting "yES" or "no", press the "Enter Button" (4-4) to save the default setting. 
 

Set the temperature unit to °C or °F 

When the lower display shows "t-CF", 
1) use the 

"▲ Button" (4-5) or the "▼ Button" (4-6) to select "C" or "F". 

C - Temperature unit is °C 
F - Temperature unit is °F 
2) After the display unit is selected ("C" or "F"), press the "Enter Button" (4-4) to save the default setting. 
 

Set sampling time (seconds) 

When the lower display shows "SP-t", 
1) use the "▲ Button" (4-5) or the "▼ Button" (4-6) to adjust the value (0, 1, 2, 5, 10, 30,60, 120, 300, 
600, 1800,3600 seconds). 
Note: 
If you set the sampling time to "0 second", it is ready for the manual datalogger function. 
2) After the sampling value is selected, press the "Enter Button" (4-4) to save the default setting. 
 

SD memory card format 

When the lower display shows "Sd F", 
1) use the "▲ Button" (4-5) or the "▼ Button" (4-6) to set the upper value to "yES" or "no". 
yES - to format the SD memory card 
no - not format the SD memory card 
2) If you select "yES", press the "Enter Button" (4-4) once again. The display will show the text "yES Ent". 
If you are sure that you wish to format the SD memory card, press the "Enter Button" once. The SD card 
will be cleared which means that all data saved on it will be deleted. 
 

Power supply from DC adaptor 

The meter can also receive its power supply from the DC 9V power adaptor (optional). Insert the plug of 
the power adaptor into the "DC 9V Power Adapter Input Socket" (4-13). The meter will permanently be 
powered ON when you use the DC ADAPTER power supply (The power button function is disabled). 
 

10  Battery replacement 

1) When the left corner of the LCD display shows "

", it is necessary to replace the battery. 

However, normally measurements can still be taken for several hours after the low battery indicator 
appears before the instrument becomes inaccurate. 
2) Loosen the "Battery Cover Screws" (4-15) and remove the "Battery Cover" (4-16) from the instrument 
and remove the battery. 
3) Replace it with 6 DC 1.5 V batteries (UM3, AA, Alkaline/heavy duty) and put the cover back on. 
4) Make sure the battery cover is secured after changing the battery. 

11  RS232 PC serial interface 

The instrument has an RS232 PC serial interface via a 3.5 mm terminal (4-12). 
The data output is a 16-digit stream which can be utilized for the user's specific application. 
An RS232 lead with the following connection will be required to link the instrument with the PC. 

Содержание PCE-T 390

Страница 1: ...ts UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instru...

Страница 2: ...alogger 9 7 Saving data from the SD card to the computer EXCEL software 10 8 Advanced settings 10 9 Power supply from DC adaptor 11 10 Battery replacement 11 11 RS232 PC serial interface 11 12 Offset...

Страница 3: ...ssible Data hold records max and min reading High accuracy Power by UM3 AA 1 5 V x 6 batteries or DC 9V adapter RS232 USB PC COMPUTER interface 2 Safety notes Please read this manual carefully and com...

Страница 4: ...1 C 0 1 F 1 C Datalogger Sampling time Setting range Auto 1 second to 3600 seconds Sampling time can be set to 1 second but memory data may get lost Manual Pushing the datalogger button once will save...

Страница 5: ...r manual off by pushing button Operating temperature 0 50 C Operating humidity Less than 85 RH Power supply Alkaline or heavy duty DC 1 5 V battery UM3 AA x 6 pcs or equivalent DC 9V adaptor input AC...

Страница 6: ...0 2102 F 0 4 2 F T type 0 1 C 50 1 100 0 C 0 4 1 C 50 0 400 0 C 0 4 0 5 C 0 1 F 58 1 148 0 F 0 4 1 8 F 58 0 752 0 F 0 4 1 F E type 0 1 C 50 1 100 0 C 0 4 1 C 50 0 900 0 C 0 4 0 5 C 0 1 F 58 1 148 0 F...

Страница 7: ...on button R button 4 7 SET button time check button 4 8 Logger button OFFSET button sampling time check button 4 9 T1 T2 T3 T4 input socket type K type J 4 10 PT1 input socket Pt 100 Ohm 4 11 PT2 inpu...

Страница 8: ...t 100 Ohm measurement only allows max two channels two probes to be used T1 T2 measurement If two probes are inserted type K J T E R S use T1 T2 input socket Pt 100 Ohm use PT1 PT2 input socket When y...

Страница 9: ...the datalogger function will be paused stop to save the measuring data into the memory circuit temporarily REC will stop flashing Note If you press the Logger Button 4 8 once again the datalogger fun...

Страница 10: ...al times to select one of the seven main functions The lower display will show dAtE Set clock time year month date hour minute second dEC Set SD card decimal character PoFF Auto power OFF management b...

Страница 11: ...utton 4 5 or the Button 4 6 to set the upper value to yES or no yES to format the SD memory card no not format the SD memory card 2 If you select yES press the Enter Button 4 4 once again The display...

Страница 12: ...egative D9 Decimal point DP position from right to left 0 no DP 1 1 DP 2 2 DP 3 3 DP D8 to D1 Display reading D1 LSD D8 MSD e g if the display reading is 1234 then D8 to D1 is 00001234 D0 End Word RS2...

Страница 13: ...least two seconds then release it The display will show 4 If you wish to make the offset adjustment for Pt 1 insert the probe into the PT1 input socket Press the L button 4 5 once so that the display...

Страница 14: ...0 cm tube 3 2 mm Thermocouple probe Type K TP 03 Meas range 50 1200 C 50 2200 F Dimensions 10 cm tube 8 mm Surface probe Type K TP 04 Meas range 50 400 C 50 752 F Dimensions temp sensing head 15 mm Pr...

Страница 15: ...contact PCE Instruments 15 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 15 2...

Отзывы: