This stirrer is provided in a box. Open the box, then remove the packaging and gently place the 
device on the firm & levelled surface. Take care while unpacking and removing all accessories. 
The user manual should be kept with the device for easy access. Please keep all packaging in 
safe storage for at least two years for warranty purpose. 

8.1 

Location and mounting 

Place the stirrer on a flat and levelled surface & ensure that all the four legs of this stirrer stands 
on the surface firmly. Avoid installing on a slippery surface or surface prone to vibration. 
 
1. 

Ideal ambient temperature is 25°C ± 1°C; avoid placing the unit in direct sunlight. 

2. 

Keep clearance of at least 20 cm from all side to increase the cooling efficiency. 

3. 

Keep the unit away from heated solution to avoid sample temperature issues. 

4. 

Do not place the equipment at a place where it becomes difficult to operate it. 

8.2 

Connecting power adaptor 

1. 

Connect one end of the power adaptor to the rear side of the stirrer and another end 
to the power supply as shown in the figure below. 

2. 

Push the power adaptor firmly for proper connection and turn ON the main switch. 

3. 

Make sure that input power source is according to stirrer requirement. 

 

Содержание PCE-MSR 150

Страница 1: ...rrer PCE MSR 150 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chang...

Страница 2: ...tents 3 7 Device description 4 8 Installation 5 8 1 Location and mounting 5 8 2 Connecting power adaptor 5 9 User interface and display 6 10 Operation 8 10 1 Switching on the device 8 10 2 Setting Tim...

Страница 3: ...in explosive atmospheres The measurement range as stated in the specifications must not be exceeded under any circumstances Place the device on a flat stable clean non slippery and fire proof surface...

Страница 4: ...diation through surrounding temperature etc Abrasion of the dispersion equipment or the rotating accessories can get into the medium you are working on The chemical reaction of PTFE can occur when in...

Страница 5: ...ts repair For repair please contact the supplier 4 Technical specifications Motor DC Max Stirring Quantity on Equip H2O 19 l Speed range 200 2200 RPM Speed control 10 RPM Step Accuracy 20 RPM Time ran...

Страница 6: ...PCE Instruments 4 7 Device description Front side 1 Stainless steel top plate 3 Start stop button 2 Digital display 4 On off button Rear Side 1 Power Socket...

Страница 7: ...ly Avoid installing on a slippery surface or surface prone to vibration 1 Ideal ambient temperature is 25 C 1 C avoid placing the unit in direct sunlight 2 Keep clearance of at least 20 cm from all si...

Страница 8: ...RPM 2 Time Press Time to select time value Then press to set Time value in minutes 3 Mins Hours Press Mins Hours to display time either in Minutes or Hour s 4 Pulse Press Pulse to activate the pulse m...

Страница 9: ...PCE Instruments 7...

Страница 10: ...e value by pressing button When time button is pressed the Mins display will blink indicating the time value is selected Once time value is selected single press will increase or decrease time value b...

Страница 11: ...error an message on display Proceed as follows in such cases 1 Problem No Display Root Cause No main power connection Solution 1 Check main power is available 2 Check that power adaptor is working pro...

Страница 12: ...ies Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012...

Страница 13: ...3 975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info pce instruments co uk info pce italia it www pce instruments com us www pce instruments com english ww...

Отзывы: