4.5

Applications

The typical applications for the PCE LDC 10 include the detection of:

Leaks in pressure and vacuum systems

Leaks in containers

Leakage points in the pneumatic brakes of trucks and trains

Leaks in piping systems

Leaks in oxygen connections in hospitals

Leaks in steam separators - leaky valves

electrical partial discharges on seals

Also defective bearings in engines and transmissions produce sounds in the ultrasonic range, which
can be protected with the PCE-LDC 10.
A handy ultrasonic transmitter is also available as an optional accessory for the detection of leaks in
pressureless system.. The transmitter is positioned in such a manner that the sound can penetrate
the piping system. The ultrasonic signal can penetrate even the smallest openings, which can then be
detected with the PCE-LDC 10.
To this is possible to detect even the smallest leaks on ship hatches, doors and windows, which in
turn opens up a further application area when checking seals.

4.5.1

Leakage detection in compressed air systems

Compressed air is one of the most costly forms of energy. In Germany alone, 60,000 compressed air
systems are consuming 14.000.000.000 KWh of electricity each year. 15% to 20% of these could easily
be saved (Peter Radgen, Fraunhofer Institut, Karlsruhe). Much of these costs are attributable to leaks in
compressed air systems. The air simply "escapes" unused.
Large openings can be detected easily (you can clearly hear the hissing sound), but often holes smaller
than 1 mm2 remain undetected because they cannot be heard. The PCE-LDC 10 is perfectly suited for
the detection of these small openings.
The unit is focused on the pipe or the component where leaks are suspected. Initially the sensitivity will
be set to half of the full value. The integrated laser will assist the location detection from a certain
distance. The sensitivity will then be varied with the volume control until the characteristic sound can
be heard.
A significant sensitivity improvement can already be attained with the help of the sound cone which is
already included in the set. Through this, it is possible to determine leakages even from larger distances.
To detect very small openings, a shotgun with a directional tip is attached onto the sensor, and the
suspicious points are directly approached in close proximity.

4.5.2

Determination of leaks in non-pressurized systems

As already mentioned the PCE-LDC 10 can also be used for the leak detection on the seals of doors,
windows and containers. For this purpose, an ultrasonic sound generator is positioned inside of the room
or the container. If small openings exist on the seals, then the ultrasonic signals will penetrate through
these towards the outside. By "traveling" along these sealing areas these leaks can be detected precisely,
through the appropriate sound in the headphones. The intensity of sound illustrates the magnitude of the
leak. The louder the sound is heard, the bigger the leak!

4.6

Scope of delivery

1x Leakage detector PCE-LDC 10
1x soundproof headphones
1xShotgun with tip
1x Sound cone
1x Power supply
1x Carrying case
1x Manual

8

Содержание PCE-LDC

Страница 1: ...1st Building Shenhua Industrial Park Meihua Road Futian District Shenzhen City Tel 0755 32978297 Email hj pce instruments cn Manual Leakage detector PCE LDC 10 Version 1 0 Date of creation 08 09 2015...

Страница 2: ...ents and controls 4 4 1 1 The front side 4 4 1 2 Sensor head 4 4 1 3 Accessories 5 4 2 Commissioning 6 4 2 1 Switching on 6 4 2 2 Louder quieter 6 4 2 3 Laser 6 4 3 Display 6 4 3 1 Signal strength lev...

Страница 3: ...ones In case of high signal levels bar graph in the red zone the volume can be correspondingly high The volume can be reduced with the help of the sensitivity adjustment Please maintain a sufficient s...

Страница 4: ...Email hj pce instruments cn Manual 4 System description 4 1 Device components and controls 4 1 1 The front side 1 2 TFT color display 2 LED status display 3 Volume sensitivity increase 4 Laser on off...

Страница 5: ...detection of the leak Through its special design the integrated laser pointer will remain usable The sound cone is simply placed onto the sensor head and slightly twisted until the latch head reaches...

Страница 6: ...volume in the sensitivity can be increased or respectively decreased in 16 steps By pressing and holding the respective button the value will automatically increase or decrease 4 2 3 Laser The integra...

Страница 7: ...ng The battery is charged within the device For this the supplied plug in power supply is connected to the built in charging socket of the PCE LDC 10 and the 230V socket If the battery is sufficiently...

Страница 8: ...pes unused Large openings can be detected easily you can clearly hear the hissing sound but often holes smaller than 1 mm2 remain undetected because they cannot be heard The PCE LDC 10 is perfectly su...