5.2 

Shutter for input sockets 

The  shutter  prevents the  simultaneous  connection  of  the test  leads  for  the multimeter function 
and the connection of the thermocouples for temperature measurement. Slide the switch upwards 
to use the multimeter function. To use the temperature measurement function, slide the switch 
down. 
 

Attention! 

The shutter is a safety feature that prevents dangerous contact voltages. The meter must not be 
operated if the shutter is defective. 
 

 

 

5.3 

Non-contact voltage detection 

 

Turn the function rotary switch to any position. 

 

Place the tip on the conductor to be tested. In case of multi-core conductors, run the tip 
along the conductor to exclude false measurements due to twisted conductors. 

 

If voltage is present, the indicator for non-contact voltage detection permanently glows 
in red. 

5.4 

Current measurement AC / DC 

Remove all test leads from the meter before making measurements with the clamp. 

 

Turn the rotary function switch to the 1000 A AC/DC position. 

 

Use the MODE key to select between AC and DC. 

 

Open  the  measuring  clamp,  enclose  the  conductor  to  be 
measured and close the clamp completely. 

 

If  the  read value is  below  50 A,  turn  the  rotary  switch to  50  A 
AC/DC to improve the resolution.  

 

5.4.1 

Zeroing DC 

With this function, you can set the measured value display to zero. 

 

As described in chapter 5.4, select current measurement DC. 

 

Press the "ZERO" key on the right side of the meter. 

 

The display should now show 0000. A slight jump of the last digit is normal. 

 

 

Содержание PCE-DC 50

Страница 1: ...DC Clamp Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Страница 2: ...ty and diode test 8 5 7 Capacitance measurement 9 5 8 Frequency and duty cycle 9 5 9 A current measurement AC DC 9 5 10 Temperature measurement 9 6 Function setting 10 6 1 Freeze measured value 10 6 2...

Страница 3: ...l as diode tests if applicable may only be carried out in a voltage free state Before replacing the batteries or the fuses all test leads must be removed from the meter The case should only be opened...

Страница 4: ...t measurement AC DC test leads Measurement range Resolution Accuracy 0 00 500 00 A 0 01 A DC 1 0 6 digits AC 1 5 30 digits 0 0 5000 0 A 0 1 A DC 1 0 6 digits AC 1 5 30 digits Voltage measurement AC DC...

Страница 5: ...0 0 5000 0 nF 0 1 nF 3 5 10 digits 0 00 50 00 F 0 01 nF 3 5 10 digits 0 0 500 0 F 0 1 F 3 5 10 digits 0 000 5 000 mF 0 001 mF 2 0 10 digits Frequency measurement Measurement range Resolution Accuracy...

Страница 6: ...fast acting AC bandwidth AC A AC V 50 Hz 400 Hz AC measurement True RMS Operating conditions 5 C 40 C 41 104 F max 80 RH at 31 C Storage conditions 20 C 60 C 4 140 F max 80 RH Power supply 9 V block b...

Страница 7: ...er current clamp Indicator non contact voltage detection HOLD key display backlight ZERO key illumination MODE Bluetooth key Function rotary switch Display MAX MIN key Sockets for K type thermocouple...

Страница 8: ...rect current Duty cycle AC Alternating current F and C Temperature unit MAX Maximum value T1 T2 T1 T2 Temperature input 1 and 2 difference MIN Minimum value n m M k Measured value sign Battery low Con...

Страница 9: ...tip along the conductor to exclude false measurements due to twisted conductors If voltage is present the indicator for non contact voltage detection permanently glows in red 5 4 Current measurement A...

Страница 10: ...the cover of the input sockets upwards Set the rotary switch to position Press the MODE key repeatedly until the continuity test icon appears on the display Plug the test leads into the measuring inpu...

Страница 11: ...ottom 5 9 A current measurement AC DC Slide the cover of the input sockets upwards Set the rotary switch to position A Use the MODE key to select AC or DC Plug the test leads into the measuring input...

Страница 12: ...ch the function on or off 6 4 Set measurement range You can influence the measurement ranges for the measuring functions voltage resistance capacitance frequency and A The default setting is automatic...

Страница 13: ...ing Remove the test leads or temperature probes from the meter If you do not use the instrument for more than 60 days remove the batteries 7 1 Cleaning Wipe the meter regularly with a damp cloth 7 2 B...

Страница 14: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Страница 15: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unit...

Отзывы: