Introduction 

Thank you for purchasing a PCE-CSM series colorimeter from PCE Instruments. 
The colorimeters PCE-CSM 1, PCE-CSM 2 and PCE-CSM4 are the ideal measuring devices for quality 
control and offer great reliability when you need to comply with certain optical requirements. The 
colorimeters have an ergonomic design and are equipped with a user-friendly operator interface. The 
difference between the 3 devices is the size of their measuring apertures. 

Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The device 
may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no 
warranty of damages or injuries caused by non-observance of the manual.

 

 

 

This colorimeter is a precise measuring device. Please avoid strong changes in the 

environmental conditions. This includes flickering lights as well as changes of the air temperature 
or air humidity. 

 

The device may only be used in the approved temperature range. 

 

Make sure the device is standing right on the measuring spot. Do not move it while the measuring 

procedure is in progress. Avoid shocks. 

 

Do not expose the device to water. Only use it in areas which fulfil the permitted environmental 

conditions. 

 

Keep the device clean and prevent dust or other particles from entering the measuring aperture. 

To clean the device, use a damp cloth. Do not use solvent-containing materials for cleaning. 

 

The case should only be opened by qualified personnel of PCE Instruments.

 

 

You must not make any technical changes to the device. 

 

The instrument should never be placed with the user interface facing an object (e. g. keyboard 

side on a table). 

 

If you do not need the device for a longer period of time, please reset the white calibration and 

store it in in the carrying case. 

 
This manual is published by PCE Instruments without any guarantee. 
 
We expressly point to our general guarantee terms which can be found in our general terms of business. 
 
If you have any questions please contact PCE Instruments. 

Содержание PCE-CSM 1

Страница 1: ...d Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instruments co...

Страница 2: ...vice 8 5 2 Taking a measurement 8 5 3 Additional functions 10 5 3 1 Record 10 5 3 2 Calibration 11 5 3 3 Connection to a PC or printer 11 5 3 4 Tolerances 12 5 3 5 Delete recorded data 12 5 3 6 Averag...

Страница 3: ...e air temperature or air humidity The device may only be used in the approved temperature range Make sure the device is standing right on the measuring spot Do not move it while the measuring procedur...

Страница 4: ...on within E ab 0 08 Measurement conditions average of 30 measurements of standard white plate Power supply Rechargeable lithium ion battery 3 7 V 3 200 mAh Charging time 8 hours Battery life Approx 5...

Страница 5: ...4 2 Interface description interfaces Mains adaptor Only use the mains adaptor included in the package If it breaks down only use substitutions with the following characteristics output 5 V DC 2 A USB...

Страница 6: ...tery in the allocated space 4 Close the battery compartment cover Charging the battery The battery can only be charged when the device is connected to a PC or to the mains adaptor Note If the battery...

Страница 7: ...first put it in the allocated space see picture below Now turn it counter clockwise until you hear a clicking noise This means that the measuring aperture is now attached properly Detaching the measur...

Страница 8: ...measuring mode is L a b C H 5 2 Taking a measurement If you turn on the device you are directed to the Standard Measurement screen To take a measurement follow these steps 1 Press and hold the testing...

Страница 9: ...ess the Enter button You are now redirected to the Sample Measurement display 2 Take another measurement just like you took the standard measurement 3 Now you can see the deviation of the sample in th...

Страница 10: ...an navigate through the sample measurements by using the arrow keys and If you want to delete a sample measurement select it and press and hold the Back button until a confirmation display appears Now...

Страница 11: ...carried out in a dark environment Additionally keep the device away at least 1 meter from reflecting objects like walls tables or other objects To start the calibration process press the Testing butto...

Страница 12: ...ss 5 3 5 Delete recorded data To delete the recorded data press the Menu button select Delete and press Enter Now you get to the delete display Here you have two different options You can either delet...

Страница 13: ...ing Enter 6 1 Colour offset Here you can activate deactivate the colour offset Use the arrow keys and for selection and confirm by pressing Enter 6 2 Language Here you can select the menu language of...

Страница 14: ...day month day year and day month year Use the arrow keys and for selection and press Enter to confirm 6 4 Contrast Here you can adjust the contrast of the display Use the arrow keys and to adjust the...

Страница 15: ...alibration After that perform a black calibration 2 Fill in the powder Fill the powder into the powder compartment of the measuring plate After that put the powder test box back together see 7 1 1 Mak...

Страница 16: ...contact PCE Instruments 8 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 8 2...

Отзывы: