Introduction 

Thank you for purchasing a flexible clamp meter PCE-CM 4 from PCE Instruments. 
The flexible clamp meter PCE-CM 4 is a high quality  meter for the measuring of current: 

It’s possible to 

measure  current  at  inaccessible  electric  conductors.  The  flexible  clamp  meter  PCE-CM  4  has  a 
measuring range up to 400 A. The meter is easy to handle. You can control the device with three buttons 
and  one  rotary  switch.  The  meter  is  able  to  measure  minimum  and  maximum  readings.  The  HOLD-
function allows freezing the data. The LCD-display has 4 digits, which means a high accuracy. The small 
and handy device promises a wide range of possibilities in any environment. 
 

Safety notes 

 
Please read this manual carefully and completely before you use the device for the first time. The device 
may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel.  There  is  no 
warranty of damages or injuries caused by non-observance of the manual. 

 
Do not operate the tester if the body of meter or the current probe looks broken. 
 
Check the main function dial and make sure it is at the correct position before each measurement. 
 
Always de-energize the circuit under test before installing flexible probe measuring head. Always inspect 
the electronics unit, connecting cable and flexible probe for damage before using this product. 
 
Exercise extreme caution, when measuring live system with voltage greater than 60V DC or 30V AC. 
 
To avoid false readings, replace the battery as soon as possible, when the battery symbol appears. 
 
The device

 

may only be used

 

in

 

approved temperature range 

 

The opening of the case should only be done by qualified personnel of the PCE Instruments. 
 

The instrument should never be placed with the user interface (e.g. keyboard side on a table) 
 
You should not make technical changes on the device 
The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner 

 
 
This user's handbook is published from PCE Instruments without any guarantee. 
 
We expressly point to our general guarantee terms, they can be found in our general terms of business. 
 
If you have any questions please contact PCE Instruments. 
 

 

Содержание PCE-CM 4

Страница 1: ...ts UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instru...

Страница 2: ...Data 4 4 System description 5 4 1 Meter discription 5 4 2 Display discription 5 5 Operation 6 5 1 Measuring instruction 6 5 2 Position sensivity 6 5 3 Button description 6 5 3 1 Backlight button 6 5 3...

Страница 3: ...e the tester if the body of meter or the current probe looks broken Check the main function dial and make sure it is at the correct position before each measurement Always de energize the circuit unde...

Страница 4: ...n the maximum will be shown OL Sample Rate 2 times sec Low Power Indication When the battery is below the proper operation range it will be shown Auto Power off If there is no key or dial operation fo...

Страница 5: ...em description 4 1 Meter discription 1 Flexible current probe 2 Probe coupling 3 Range switch 4 Data hold button 5 MIN MAX button 6 Backlight button 7 LCD display 8 Battery compartment cover 4 2 Displ...

Страница 6: ...ote Measurement uncertainty assumes centralized primary conductor at optimum position no external electrical or magnetic field and within operating temperature range 5 3 Button description 5 3 1 Backl...

Страница 7: ...will appear on the LCD display and the battery needs to be replaced 2 Remove the flexible current probe from any measuring object 3 Switch the main dial to OFF 4 Open the battery door with a screwdri...

Страница 8: ...contact PCE Instruments 6 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 6 2 P...

Отзывы: