5.2.2 Detection of fuses
In a building with several apartments you use the terminals L and N in the socket of any apartment to
provide the flow of the signals from the transmitter, and set the power of the transmitter at an appropriate
level.
Preparation:
- Turn off all air switches in the distribution box.
- Connect the transmitter according to the following figure.
- The identification and positioning of fuses strongly depends on the wiring situation in the distribution
box. To carry out the search of fuses as precisely as possible, the cover of the distribution box should be
opened or removed and the supply cable of the fuse searched.
- During the search process the fuse with the strongest and most stable signals is the one that is
searched. Due to signal coupling the locator can also detect the signals from other fuses, but the strength
of these signals is usually relatively weak.
- When searching, it is better to insert the sensor of the locator in the inlet of the fuse box in order to
achieve the best search result.
- Set the power of the transmitter in order to adjust it to different search radii. Select the manual mode on
the receiver and the appropriate reception sensitivity to locate the current circuit accurately.