1. Humidity & Temperature Sensor

2.

Thermocouple input jack

3.

Laser pointer beam

4.

Laser sensor

5.

USB Interface

6.

LCD Display

7.

Humidity & Temperature Sensor Max/Min

Button

8.

TEMP./Wet Bulb/Dew Point Button

9.

TEMP./Wet Bulb/Dew Point/%RH hold

Button

1 O. IR Measurement Trigger 

11. 

º

F/

º

C Button 

12. IR OR Type K Max/Min

Button

13.

IR OR Type K Hold Button

14.

Backlight Button

15.

 Power Button

Содержание PCE-320

Страница 1: ...ide US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign way Hampshire So...

Страница 2: ...lt in laser pointer increases target accuracy while the backlight LCD and handy push buttons combine for convenient ergonomic operation Type K thermocouple functionality and Humidity Temperature Senso...

Страница 3: ...nd accuracy 4 Fast response all data calculated four times in one second 5 Standard type k NiCr NiAI Thermocouple input jack suitable for all kinds of type k probe 6 Infrared to measure surface temp 7...

Страница 4: ...1 SAFETV Use extreme caution when the laser beam is turned on Do not let the beam enter your eye another person s eye or the eye of an animal Be careful not to let the beam on a reflective surface st...

Страница 5: ...es larger The relationship between distance and spot size for each unit is listed below The focal point for each unit is 914mm 36 The spot sizes indicate 90 encircled energy Fig 1 MODEL PCE 320 Distan...

Страница 6: ...4 F 0 1 F C 9 0 F 5 0 Temp 50 20 C C 4 to932 F 0 1 F C 2 reading 20 500 C or 4 F 2 C AirTemp 4 140 F 0 1 F C 2 0 F 1 0 20 60 C C Humidity 10 90 0 1 RH 2 others 0 1 RH 3 Wet Bulb 6 88 140 F 0 1 F C 21...

Страница 7: ...3 Front Description 7...

Страница 8: ...or 5 USB Interface 6 LCD Display 7 Humidity Temperature Sensor Max Min Button 8 TEMP Wet Bulb Dew Point Button 9 TEMP Wet Bulb Dew Point RH hold Button 1O IR Measurement Trigger 11 F C Button 12 IR OR...

Страница 9: ...HPC LINK 1BHBJBHff RH IRTEMPii lm CD nnnn aaaa RECMAXMINH CD Auto Power Off Indication Battery lndication Air Temp Value IR Temp Type K Temp lndication Communication lndication Air Humidity J IR Temp...

Страница 10: ...ear on the upper left corner of the display Press the Max Min to view maximum and minimum recorded readings Press and Hold the Max Min button until the display returns to standard operation to exit th...

Страница 11: ...upper right corner of the display Press the HOLD button again to return to normal operation and the HOLD icon will disappear 4 Press to measure surface temp By activating IR function Release to hol d...

Страница 12: ...nimum recorded readings Press and Hold the Max Min button until the display retums to standard operation to exit the Max Min function and the REC icon on the lower left comer will disappear 7 9 Press...

Страница 13: ...meter will automatically turn off after 15 minutes in the normal When you turn on the meter and press the button first an disAPO appears on th e LCD then you ean release the button and th e automatic...

Страница 14: ...nship for a period of two years from the date of purchase This warranty covers normal operation and does not cover batter misuse abuse alteration tampering neglect improper maintenance or damage resul...

Отзывы: