background image

 

 

 

©  PCE Instruments 

 

Introduction  

The  anemometer  PCE-ADL  11  is  a  data  logger  for  wind  speed.  The  configuration  of  the 
anemometer  is  done  via  the  supplied  software.  The  wind  speed  meter  measures  various 
parameters.  These  include  m/s,  km/h,  knots,  mph  and  ft/min.  In  addition  to  the  measurement 
parameters,  the  measurement  intervals  can  be  set  in  the  software.  The  memory  has  enough 
capacity for 60,000 measured values. After completion of the measurement series, the data can 
be  read  out  on  the  computer  via  the  software.  The  measurement  results  are  displayed  either 
graphically as a curve or in tabular form.

 

Delivery scope 

1 x anemometer PCE-ADL 11 
1 x mounting equipment 
1 x software 
1 x impeller 
1 x 3.6 V lithium thionyl chloride battery 
1 x user manual 

Specifications 

Measurement range 

1.2 ... 30.0 m/s 
4.3 ... 108.0 km/h 
2.33 ... 58.32 knots 
2.69 ... 67.2 mph 
236 ... 5906 ft/min 

Resolution 

0.01 m/s 
0.1 km/h 
0.1 knots 
0.1 mph 
1 ft/min 

Accuracy 

m/s: ±(3 % + 0.20 m/s) 
km/h: ±(3 % + 1.0 km/h) 
knots: ±(3 % + 0.4 knots) 
mph: ±(3 % + 0.4 mph) 
ft/min: ±(3 % + 40 ft/min) 

Memory 

for up to 60000 measured values 

Data interface 

USB for data transfer 

PC software 

for data evaluation with graphical 
representation 

Selectable recording intervals 

3 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 
30 min, 1 h, 2 h, 3 h, 6 h, 12 h 

Operating status 

indicated by red, yellow and green LED 

Alarm when extreme values are exceeded 

yes 

Measuring modes 

automatic and manual start of 
measurement 

Sensor 

anemometer 

Power supply 

lithium thionyl chloride battery, 3.6 V 
Mignon 

Low battery voltage alarm 

Yes 

Operating conditions 

0 ... +50 °C / 32 ... 122°F, <80 % RH 

Max. height above sea level 

2000 m / 6561 ft 

Weight 

49 g / <1 lb 

Dimensions 

145 x 35 x 30 mm / 5.7 x 1.4 x 1.2 in 

Содержание ADL 11

Страница 1: ...ter PCE ADL 11 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Страница 2: ...on 3 6 1 Icon description 3 6 2 Graph description 4 6 3 Data download 5 6 4 Configure meter 6 6 5 Zoom into graph 7 6 6 Print graph 7 6 7 Export and import data 7 6 8 Generate CSV file 7 6 9 Further s...

Страница 3: ...ents personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp cloth Use only pH neutral cleaner...

Страница 4: ...ttery 1 x user manual 4 Specifications Measurement range 1 2 30 0 m s 4 3 108 0 km h 2 33 58 32 knots 2 69 67 2 mph 236 5906 ft min Resolution 0 01 m s 0 1 km h 0 1 knots 0 1 mph 1 ft min Accuracy m s...

Страница 5: ...form 6 1 Icon description Icon Description Explanation Download The measured values from the PCE ADL 11 can be downloaded here Setting The PCE ADL 11 can be configured here Open Measurement data can...

Страница 6: ...storage interval is displayed here MAX Maximum value The highest measured value in the set storage interval is displayed here MIN Minimum value The lowest measured value in the set storage interval i...

Страница 7: ...ph as a dashed red line 6 3 Data download To download the data from the PCE ADL 11 first connect the meter to your PC Then click on the Download icon Another window appears and the software automatica...

Страница 8: ...ation of the storage rate Recording Time This indicates how long the meter measures with the settings made until the measurement is finished LED Flash Cycle Here you can specify when the status LED sh...

Страница 9: ...nce on View all 6 6 Print graph To print the displayed graph click on Print Now you can print the graph Important The current view is always printed This means that if you have zoomed into the graph o...

Страница 10: ...show or hide the line for the lowest measured values Average trace Here you can show or hide the line for the average values RT trace Show or hide real time line 6 10 Change graph colours To change i...

Страница 11: ...place it The data logger does not lose any saved data when the battery is discharged or replaced However the data storage process is stopped and cannot be restarted until the battery has been replaced...

Страница 12: ...flashes twice every 10 20 or 30 seconds Meter ready for logging Press the yellow key on the back green LED flashes three times Data recording started during the manual start up process Red LED flashe...

Страница 13: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Страница 14: ...Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 05...

Отзывы: