background image

 

 

©  PCE Instruments 

 
 

Safety Notes 

Please read this manual carefully and completely before you use the device for the first time. 
The device may only be used by qualified personnel and repaired by PCE Instruments 
personnel. Damage or injuries caused by non-observance of the manual are excluded from our 
liability and not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used 
otherwise, this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, 
relative humidity, …) are within the ranges stated in the technical specifications. Do 
not expose the device to extreme temperatures, direct sunlight, extreme humidity or 
moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral 
cleaner, no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. If the viscosity of the liquid is too high, the spindle stops and a 
warning appears on the display. In this case, the device must be restarted. 

 

If the viscometer makes strange noises during the operation or if there is any kind of 
smoke or spark generation, turn it off immediately and contact our customer service. 

 

Do not set up the viscometer close to the strong electric or magnetic fields. 

 

Make sure that the instrument is levelled properly before taking a measurement. Use 
a level. 

 

Use the device only in the upright position, as otherwise it may cause damage to the 
device.  

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 

 

Содержание PCE-RVI 6

Страница 1: ...CE RVI 6 viscometer User Manual User manuals in various languages Deutsch fran ais italiano espa ol portugu s nederlands t rk polski can be downloaded here www pce instruments com Last change 19 July...

Страница 2: ...ontents 1 Safety Notes 3 2 Specifications 4 2 1 Technical specifications 4 2 2 Delivery 4 3 System Description 5 3 1 Device 5 4 Preparation 5 5 Operation 6 5 1 Measurement 6 5 2 Settings 7 5 3 Print 7...

Страница 3: ...e device must only be used with accessories from PCE Instruments or equivalent Before each use inspect the case for visible damage If any damage is visible do not use the device Do not use the instrum...

Страница 4: ...alue Repeatability 1 0 of full scale value Volume of the measuring cup Ca 800 ml Stroke 90 mm Power supply 110V 220V 50 60Hz Power 10 W Humidity 75 Dimensions 360 x 280 x 730 mm Weight 10 kg 2 2 Deliv...

Страница 5: ...even surface Take the spindle out of the box and attach it to on the shaft To do this push it into the opening at the bottom of the shaft and tighten it with the locking screw Use the lever to move t...

Страница 6: ...desired sample Note that the sample has to reach the marking on the spindle above the wings If necessary use one of the supplied stands 2 Move the lever down until the lowest position is reached The...

Страница 7: ...just date and time Simply press the button Now the year starts flashing Use the and buttons to change the value With the help of and buttons you can switch to the previous or to the next parameter To...

Страница 8: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our device...

Страница 9: ...Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce instruments com english www pce inst...

Отзывы: