Important Notes: 

On the edge of wind direction sensor, there are four alphabet letter of “N”,”E”,”S” and “W” 
representing for the direction of North, East, South and West. Wind direction sensor has to 
be adjusted so that the directions on the sensor are matching with your real location. 
Permanent wind direction error will be introduced when the wind direction sensor is not 
positioned correctly during installation. 
 
 
Wind speed sensor wire has to be inserted into the phone jacket on wind direction sensor. 
Wind direction sensor wire has to be inserted into the phone jacket located on the thermo-
hygro sensor with marking of “Wind” on top. 
The rain sensor wire has to be inserted into the phone jacket located on the thermo-hygro 
sensor with marking of “Rain” on top. 
 

System Start 

Insert two pieces of LR6 (AA size) batteries into the transmitter, the LED located in the 
middle front case of transmitter will be turned on for 4 seconds and then it will be off and start 
to work normally. The transmitter will make a data transmission and then start radio 
controlled time reception routine. If time signal can be detected correctly, then the LED will 
start to flash 5 times indicating time signal has been found correctly. When time signal is bad 
and reception is not possible, the transmitter will terminate radio controlled time reception 
within one minute and resume normal mode. When there is a data transmission happened, 
the LED will be on for 20ms. During radio controlled time reception period, there is no 
transmission and normal transmission will only resume after time reception routine is 
complete. The longest time for radio controlled time reception is 5 minutes. 
After inserting the batteries into the Weather Station, all LCD segments will be turned on for a 
few seconds, all possible display segments are turned on for checking. 
After this, the weather station will make initial measurement and start to register the 
transmitter ( the radio reception icon will be turned on). Before there is outdoor data received, 
it is not allowed to touch the LCD, otherwise the outdoor sensor learning mode will be 
terminated right after the touch of LCD. When outdoor transmitter has been registered, the 
Touch Screen Weather Station will automatically switch to the normal display mode from 
which all further settings can be performed by the user. 

 

Содержание PCE-FWS 20

Страница 1: ...ical Services Ltd Unit N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 44 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial needs com Man...

Страница 2: ...ositioning 8 Setting Up 8 indoor temperature 8 outdoor temperature 9 Indoor humidity 10 Outdoor humidity 11 Wind speed 11 Rain 12 Weather forecast 13 Pressure 13 Pressure bar graph 14 Time 14 Date 15...

Страница 3: ...TRIC PRESSURE A barometer is a device that measures the pressure of the air pushing on it this measurement is called the barometric pressure We don t actually feel the barometric pressure because the...

Страница 4: ...e of the Weather Station is the readout of all measured and displayed time and weather data on a PC as well as the ability to upload the data to Internet Web Sites Important Operation Notes All action...

Страница 5: ...info tursdaletechnicalservices co uk 5 Setup Sensors...

Страница 6: ...info tursdaletechnicalservices co uk 6...

Страница 7: ...ntrolled time reception routine If time signal can be detected correctly then the LED will start to flash 5 times indicating time signal has been found correctly When time signal is bad and reception...

Страница 8: ...o transmission they can mostly be overcome by moving the mounting locations Note Commonly the radio communication between receiver and transmitter in the open field can reach a distance of up to 330 f...

Страница 9: ...for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 4...

Страница 10: ...ERATURE section the fifth time to display maximum outdoor temperature record the recorded maximum value will be flashing MAX icon will light up Hold the flashing max value for 3s the maximum value wil...

Страница 11: ...ilar to Indoor humidity Wind speed Activate the wind related setting by 1 Touch the WIND SPEED section button and button will be flashing Touch the button or button to Shift the display between Wind A...

Страница 12: ...rain fall unit between mm inch 3 Touch the rain section the third time to set the high alarm function the ON OFF and button will be flashing HI AL icon will light up Touch the button or button to cha...

Страница 13: ...l be flashing Touch the button or button to set the storm threshold from 3 9h Pa default 4 hPa Pressure 1 Touch the PRESSURE section button and button will be flashing Touch the button or button to Sh...

Страница 14: ...mum pressure record to display maximum pressure the recorded maximum value will be flashing MAX icon will light up as well Hold the maximum value for 3s the maximum value will be reset to current read...

Страница 15: ...on to Shift between DD MM format and MM DD format for the date 3 Touch the DATE section the third time button and button will be flashing Touch the button or button to set the year Hold the button or...

Страница 16: ...er data with time and date These data sets are being stored in non volatile ring buffer memory EEPROM and will not be lost even in case of an interruption of power supply e g change of batteries In ca...

Страница 17: ...sub line of the window the program will show related information regarding the read of all history data into the PC Please note however when there is large amount of data is being uploaded it will ta...

Страница 18: ...he help menu Specifications Outdoor data Transmission distance in open field 100m 330 feet Frequency 868MHZ Europe 915MHz North America Temperature range 40 C 65 C 40 to 149 Resolution 0 1 C 0 2 Measu...

Страница 19: ...form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors...

Страница 20: ...0 Touch Screen Weather Station for setting up the Weather Station After successful checking install the EasyWeather software as follows 1 Switch on your PC and insert the CD ROM into the CD ROM Drive...

Страница 21: ...ware so once you have done your setting on the base unit then you don t need to make any setting changes on the PC software However you can still easily make any setting changes you wanted from the PC...

Страница 22: ...on button display and setup system configuration This section is used to set up PC software display base station units as well as able or disable the corresponding alarm function Once you made your ch...

Страница 23: ...up system alarm value This section is used to set the desired time high or low alarm value for the base unit Once you made your choice choose Save to make the setting effective If you don t want to ma...

Страница 24: ...icalservices co uk 24 display min and max recorded value This section is used to display the recorded min and max value recorded with time stamp Min Max reset can only be done through key operation on...

Страница 25: ...ther application purpose When memory on base station is full press Clear Memory button to refresh the memory space on the base station remember to upload all data before pressing this button If you wa...

Страница 26: ...a in graph mode In this section you can see the history data plotted in graph format for easier observation If you want to see more details just use your mouse to select the area you wanted and the di...

Страница 27: ...info tursdaletechnicalservices co uk 27...

Страница 28: ...d problem with this software To make the graph function working properly please check the following step 1 Find the folder where the EasyWeahter exe file is located 2 Create a file name reg_graph bat...

Страница 29: ...st uploading is lost permanently Before memory is used up memory icon on LCD display showing 100 full remember to upload weather history data to PC periodically If there is a reset happened for the ra...