Recommendation for EMF measurement 

   It is recommended to measure the presence of the
electromagnetic field inside and outside of your home
and business locations regularly.
   As "hot spots" are detected by the EMF tester, 
re-arrangement of the living and working areas is
lightly recommended. Always try the best to avoid
long term exposure to strong electromagnetic field.

6-2 Data Hold

During the measurement, press the " Hold Button " ( 5-4,
Fig. 1 ) once will hold the measured value & the LCD will
display a " HOLD " symbol.

* Press the " Hold Button " once again will release the data

hold function.

6-3 Data Record ( Max., Min. reading )

* The data record function records the maximum and

minimum readings. Press the " REC Button " ( 5-3, Fig.
1 ) once to start the Data Record function and there
will be a " REC " symbol on the display.

* When the " REC " symbol on the display :

a) Press the " REC Button " ( 5-3, Fig. 1 ) once, the

" REC MAX " symbol along with the maximum value
will appear on the display.
If intend to delete the maximum value, just press
the " Hold button " ( 5-4, Fig. 1 ) once, the display
will show the " REC " symbol only & execute the
memory function continuously.

b) Press the " REC button " ( 5-3, Fig. 1 ) again, the

" REC. MIN. " symbol along with the minimum value
will appear on the display.
If intend to delete the minimum value, just press
the " Hold button " ( 5-4, Fig. 1 ) once, then
the display will show the " REC " symbol only &
execute the  memory function continuously.

6

Содержание PCE-EMF 823

Страница 1: ...into the field of precision measurement Although this EMF TESTER is a complex and delicate instrument its durable structure will allow many years of use if proper operating t e c h n i q u e s a r e d...

Страница 2: ...3 REC Button 4 5 4 HOLD Button 4 5 5 Range Button 4 5 6 Unit Button 4 5 7 Backlight Button 4 5 8 Tripod Fix Nut 4 5 9 Stand 4 5 10 Battery Cover Compartment 4 5 11 DC 9V Power Adapter Input Socket 4...

Страница 3: ...r circuit assures high accuracy and provides special functions and features Records Maximum Minimum readings with Recall LCD dspaly is with the backlight installation Auto power Off or manual power Of...

Страница 4: ...t Custom one chip of microprocessor LSI circuit Measurement EMF Electromagnetic field radiation EMF micro Tesla Range Resolution 20 micro Tesla x 0 01 micro Tesla 200 micro Tesla x 0 1 micro Tesla 2 0...

Страница 5: ...micro Tesla 200 micro Tesla 0 1 micro Tesla 2 000 micro Tesla 1 micro Tesla 200 mG 0 1 mG 2 000 mG 1 mG 20 000 mG 10 mG mG milli Gauss 1 micro Tesla 10 milli Gauss Range Accuracy 20 micro Tesla 4 3 d...

Страница 6: ...Display 5 2 Power Button 5 3 REC Button 5 4 HOLD Button 5 5 Range Button 5 6 Unit Button 5 7 Backlight Button 5 8 Tripod Fix Nut 5 9 Stand 5 10 Battery Cover Compartmen 5 11 DC 9V Power Adapter Input...

Страница 7: ...EMF measurement value EMF Sensor Position is in the area of 5 13 Fig 1 Due to the electromagnetic interference of the environment the display reading may show small values before testing for example l...

Страница 8: ...x Min reading The data record function records the maximum and minimum readings Press the REC Button 5 3 Fig 1 once to start the Data Record function and there will be a REC symbol on the display When...

Страница 9: ...nce the LCD backlight will be switched to Off Press the Back light Button once again will switch the Display backlight installation On again 6 5 Auto power OFF disable The instrument has built in Auto...

Страница 10: ...e battery cover is secured after changing the battery 8 OPTIONAL ACCESSORIES Input voltage 100 to 240 ACV 50 60 Hz DC 9V POWER ADAPTER Output voltage Regulation DC 9V 1 Amp rating max Output plug roun...

Отзывы: