4. SPECIFICATIONS

4-1 General Specifications
Display

LCD size : 48.8 mm x 25.3 mm.
LCD is with the backlight installation.

Circuit

Custom one-chip of microprocessor 
LSI circuit.

Measurement

EMF ( Electromagnetic field radiation )

EMF

micro Tesla :

Range /Resolution

20 micro Tesla x 0.01 micro Tesla
200 micro Tesla x 0.1 micro Tesla
2,000 micro Tesla x 1 micro Tesla

milli-Gauss :

200 mG x 0.1 mG
2,000 mG x 1 mG
20,000 mG x 10 mG

* mG : milli-Gauss
* 1 micro Tesla = 10 milli-Gauss

EMF Band width

30 Hz to 300 Hz.

Axes no. of EMF

Single axis.

Over-input

Display shows ' 

 ' .

Sampling Time

Approx. 1 second.

Battery

DC 9 V battery (006P, 6F22).

Power Current

Approx. DC 5 mA.

* Back light Off.

Operating 

0 to 50 

.

Temperature
Operating 

Less than 80% R.H.

Humidity

2

Содержание PCE-EMF 823

Страница 1: ...into the field of precision measurement Although this EMF TESTER is a complex and delicate instrument its durable structure will allow many years of use if proper operating t e c h n i q u e s a r e d...

Страница 2: ...3 REC Button 4 5 4 HOLD Button 4 5 5 Range Button 4 5 6 Unit Button 4 5 7 Backlight Button 4 5 8 Tripod Fix Nut 4 5 9 Stand 4 5 10 Battery Cover Compartment 4 5 11 DC 9V Power Adapter Input Socket 4...

Страница 3: ...r circuit assures high accuracy and provides special functions and features Records Maximum Minimum readings with Recall LCD dspaly is with the backlight installation Auto power Off or manual power Of...

Страница 4: ...t Custom one chip of microprocessor LSI circuit Measurement EMF Electromagnetic field radiation EMF micro Tesla Range Resolution 20 micro Tesla x 0 01 micro Tesla 200 micro Tesla x 0 1 micro Tesla 2 0...

Страница 5: ...micro Tesla 200 micro Tesla 0 1 micro Tesla 2 000 micro Tesla 1 micro Tesla 200 mG 0 1 mG 2 000 mG 1 mG 20 000 mG 10 mG mG milli Gauss 1 micro Tesla 10 milli Gauss Range Accuracy 20 micro Tesla 4 3 d...

Страница 6: ...Display 5 2 Power Button 5 3 REC Button 5 4 HOLD Button 5 5 Range Button 5 6 Unit Button 5 7 Backlight Button 5 8 Tripod Fix Nut 5 9 Stand 5 10 Battery Cover Compartmen 5 11 DC 9V Power Adapter Input...

Страница 7: ...EMF measurement value EMF Sensor Position is in the area of 5 13 Fig 1 Due to the electromagnetic interference of the environment the display reading may show small values before testing for example l...

Страница 8: ...x Min reading The data record function records the maximum and minimum readings Press the REC Button 5 3 Fig 1 once to start the Data Record function and there will be a REC symbol on the display When...

Страница 9: ...nce the LCD backlight will be switched to Off Press the Back light Button once again will switch the Display backlight installation On again 6 5 Auto power OFF disable The instrument has built in Auto...

Страница 10: ...e battery cover is secured after changing the battery 8 OPTIONAL ACCESSORIES Input voltage 100 to 240 ACV 50 60 Hz DC 9V POWER ADAPTER Output voltage Regulation DC 9V 1 Amp rating max Output plug roun...

Отзывы: