background image

 

 

 

©  PCE Instruments 

 

6.4.2 

Selecting the cable type 

To  measure  the  cable  length  accurately,  it  is  necessary  to  select  the  correct  cable  type  and 
propagation velocity of the measuring signal (VOP) prior to the measurement. 

1. 

Press the 

 key to be able to select the cable type from the database of the cable length 

tester with the 

 key. 

2. 

The  velocity  of  propagation  of  the  selected  cable  can  only  be  changed  manually  for  this 

measurement. To do so, press and hold the 

key in measuring mode. In the upper right 

part of the display, the VOP value will now be displayed with a black background. This VOP 

value can now be changed via the 

 and 

 keys. To confirm the change, short-press the 

 key. 

6.4.3 

Cable length measurement 

If you have selected the correct cable as described in 6.4.2, you can now make a measurement 

by pressing the 

 key. After the cable length measurement, the reading will be displayed. To 

leave measuring mode, short-press the 

 key. 

 

6.5 

VOP library 

To open  the  VOP  library,  first  go to the  menu. Select  the  menu  item 

“Velocity of propagation“. 

Then select 

“VOP Library“. Then select the library you wish to open. You can select either the 

library 

“Coaxial Cable“ or “Data Cable“. 

 

 

 

Содержание PCE-CLT 10

Страница 1: ...E CLT 10 Electrical Tester User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Страница 2: ...ations 2 4 Delivery contents 2 5 Device description 3 6 Operation 3 6 1 Preparation inserting the batteries 3 6 2 Turn on off cable length tester 4 6 3 Main menu 4 6 4 Cable length measurement 4 6 5 V...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...easurement units m ft Resolution 0 1 m Measuring principle Time domain reflectometer Selection area Automatic control range Measurement accuracy 2 of reading 0 2 m 100 m 2 of reading 0 5 m 100 m Imped...

Страница 5: ...paration inserting the batteries To run the cable length meter the included batteries must be inserted first To do so turn around the meter and open the battery compartment cover at the rear side Inse...

Страница 6: ...owing functions which you can confirm with Cable length measurement Setting the velocity of propagation History of past measurements System settings Up in the menu Down in the menu Confirm selection w...

Страница 7: ...ength measurements the screen will look as follows after making a selection Measuring mode for coaxial cables and cables connected to the meter with a measuring adaptor Measuring mode for the length m...

Страница 8: ...In the upper right part of the display the VOP value will now be displayed with a black background This VOP value can now be changed via the and keys To confirm the change short press the key 6 4 3 C...

Страница 9: ...ts 7 As a last step select your cable with the key You can go back to the library by pressing the key With the key you can delete the current cable To confirm the deletion press To cancel the deletion...

Страница 10: ...1 COR50 AIR 12 CAT4UT NEXAN 12 COR75 AIR 13 CAT4ST NEXAN 13 COR550 AIRPE 14 CAT5UT IBDN 14 COR575 AIRPE 15 CAT5ST IBDN 15 RG6U FOAMED 16 CAT6UT IBDN 16 RG59BU VBFH 17 CAT6ST SIEMON 17 RG62AU PVC 18 CA...

Страница 11: ...can select the type of cable You can choose Coaxial cable or Network cable To change the value press the key to select the box The value can then be changed with the keys Press to confirm the entered...

Страница 12: ...able You can choose Coaxial cable or Network cable To change the value press the key to select the box The value can then be changed with the keys Press to confirm the entered value In the Producer bo...

Страница 13: ...istory of the cables last used first enter the menu Then select History The cables last used will be displayed directly for your selection You can select the desired cable with the keys To confirm you...

Страница 14: ...Format JJJJ MM TT Auto OFF time Here you can set the time of inactivity after which the meter turns off automatically Possible options 10 20 30 40 50 or 60 minutes Language Here you can set the langua...

Страница 15: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Страница 16: ...0583 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info industrial needs com info pce italia it www pce instruments com deutsch www pce instrumen...

Отзывы: