Display Resolution 

 

Velocity  

 

 

1 fpm    

 

 

0.01 m/s

 

 

Temperature    

 

1 °F  

 

 

 

0.1 °C

 

Accuracy 

 

Velocity  

 

 

±1% reading ±4fpm 

 

±1% reading ±0.02 m/s 

 

Temperature    

 

±2 °F    

 

 

±1 °C

 

General Specifications 

Storage Temperature   

 

 

14 to 140 °F 

 

-10 to 60 °C 

Operating Temperature 

 

 

32 to 140 °F    

0 to 60 °C 

Power Source   

 

 

 

9-Volt battery 

Battery Life  

 

 

 

 

Approximately 40 hours continuous use 

Dimensions (LxWxD)   

 

 

11 in. × 4.5 in. ×2.6 in. 280 mm × 112mm × 65 mm 

Weight (excluding battery) 

 

 

 

 

10 oz.    

 

275 g 

 

7.  Disposal 

Batteries may not be put in the household waste. They have to be given in the set up collection points.  
 
To follow the WEEE guidelines (Waste of Electrical and Electronic Equipment) we take our devices and 
either recycle them or give them to a recycling company.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

NOTE: 

"This instrument doesn’t have ATEX protection, so it should not be used in potentially 

explosive atmospheres (powder, flammable gases)." 
 

 
Please contact PCE Instruments if you have any questions concerning our products, service etc.  
 

Here you will find an overview of our measuring devices: 

http://www.industrial-needs.com/measuring-instruments.htm

 

Here you will find an overview of our scales and balances: 

http://www.industrial-needs.com/balances.htm

 

Here you will find an overview of our laboratory equipment:  

http://www.industrial-needs.com/laboratory-equipment.htm

 

Here you will find an overview of our control systems:  

http://www.industrial-needs.com/control-systems.htm

 

 
WEEE.-Reg. 

–Nr.: DE69278128 

 

 

 

 

 

 

 

  

 

 

Содержание LCA 301

Страница 1: ...9 2014 www industrial needs com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southhampton Hampshire United Kingdom SO31 4RF Phone 44 0 2380 98703 0 Fax 44 0 2380 98703 9 info...

Страница 2: ...ttery 3 3 2 LCD display 3 3 3 Auto Shutdown 3 4 Detailed Description 4 4 1 English Metric Unit Selection 4 4 2 Measuring Air Velocity 4 4 3 Measuring Air Volume 4 4 4 Low battery indication 5 4 5 Seri...

Страница 3: ...tor The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE T...

Страница 4: ...is instrument is not designed for gas mixtures other than air Use with explosive and or other dangerous gas mixtures is not recommended and is at the operator s own risk 3 General Description 3 1 Inst...

Страница 5: ...stream for about five seconds before pressing the trigger key to take a reading This enables the vane anemometer to reach a steady speed and the average reading will be more accurate To take a single...

Страница 6: ...h the trigger and mode key when switching on the device 5 Care Maintenance and Service Please return the Product Registration Card immediately to the manufacturer This allows him to send service remin...

Страница 7: ...of Electrical and Electronic Equipment we take our devices and either recycle them or give them to a recycling company NOTE This instrument doesn t have ATEX protection so it should not be used in po...

Страница 8: ...measure the volume flow rate the area entered in the instrument needs to be set in relation to the 100 mm vane diameter The correct value to be entered can be found in the Air Cone manual that comes...

Страница 9: ...Manual www industrial needs com 8...

Отзывы: