TROUBLESHOOTING / INFORMATION
INDICATION
TYPE OF FAULT
MEASURE
Solid red light
RCCB has tripped or EV earth check
error is detected.
Reset. Refer to section on resetting the residual-
current or personal protective current breaker.
Solid red light for 3 sec
RFID card not accepted.
Check RFID card
Red fast flash light
DC current >6mA - charging has
stopped.
Solid yellow light
Broken cable.
Check charging cable
Yellow flash light
Motor lock socket not in latched
position.
Contact a qualified electrician.
Shifting red/green/yellow light
DC detection hardware error.
Purple flash light
Chargebox overheating, charging has
stopped.
After cool down, the charging process is restarted
automatically.
White fast flash light
Search light indication.
Comparison with complete operating instructions
One quick white flash light repeating
every minute
Indicate an error in DLM function.
Auto reset occurs as soon as the connection to the
energy meter is re-established.
Solid blue light
RFID accepted - waiting to start
charging.
Shifting blue light intensity
EV charging in progress.
Shifting red/blue light
Software upgrade in progress.
Shifting blue/black light
Chargesession not enabled due to
scheduled mood.
Solid green light
Charger in idle, waiting for EV to
connect.
Green flash light
EV connected, wait to start charging or
EV has finish charging.
Green fast flash light
RFID reader is active, waiting to read
card for authorization.