To make settings for this measuring mode, press the "Menu" key twice. 
 

 

 

Setting 

Meaning 

Start Load 

Here you set the force at which the average measurement should start. 

Initial Delay 

Here you enter the time span at the beginning of the measurement that is 
not  to  be  taken  into  account  in  the  average  measurement.  Available 
settings:  0.0  ...  300.0 seconds.  Resolution  0.1 seconds.  This  parameter 
only affects the MOD1 function. 

Averaging Time 

Here you set the measuring time for the average measurement. Available 
settings:  0.0  ...  300.0 seconds.  Resolution  0.1 seconds.  This  parameter 
only affects the MOD1 function. 

Average Mode 

Here you select between the MOD1 and MOD2 function. 

 
To select a parameter, use the arrow keys. Press the "Enter" key to select a parameter. Use the 
arrow keys again to change the parameter properties. Press the "Enter" key again to apply the 
settings you have made.  

5.3.1 

Measuring procedure 

When "WAIT" is displayed on the screen, the meter waits until the set minimum load is applied. 
 

 

 

When "DELAY" is shown on the display, the force gauge will wait until the set minimum time has 
elapsed.  
 

 

 

 

Содержание CTT 10

Страница 1: ...s Torque Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Страница 2: ...y description 3 4 2 Display description 4 5 Measuring modes 4 5 1 Real Time 4 5 2 Peak 4 5 3 Average Mode 5 5 4 Save Mode 7 6 View print saved data 8 7 Alarm limits 9 8 Communication of interface and...

Страница 3: ...fied PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp cloth Use only pH...

Страница 4: ...or up to 100 measured values Display LCD graphical display Power supply 230 V Sample size 20 200 mm diameter Sample weight max 5 kg Environmental conditions 5 45 C 35 65 RH Dimensions 280 x 210 x 200...

Страница 5: ...t between the individual menu pages or to exit the menu Enter key Open parameters and apply settings Unit Up key Unit key Increase value Go up one parameter Select units DATA Down key Data key Decreas...

Страница 6: ...value is outside the measurement range OVER is shown on the display and an acoustic signal is generated Only when the measured value is back within the measurement range a normal measurement can be re...

Страница 7: ...e is displayed starting from the set minimum force and over the set period of time MOD2 This function calculates the average above the set minimum measured value When the measured value falls below th...

Страница 8: ...e you set the measuring time for the average measurement Available settings 0 0 300 0 seconds Resolution 0 1 seconds This parameter only affects the MOD1 function Average Mode Here you select between...

Страница 9: ...e time Up to 10 average values can be saved 5 4 Save Mode In SAVE Mode the highest measured values can be saved in a single measurement run In the memory you can save 100 measured values memory item n...

Страница 10: ...average of all saved values are displayed here Print Data The saved measurement data is printed here Clear All Data Deletes all measured values Under View Data the memory item number the direction of...

Страница 11: ...counterclockwise L Limit Lowest limit value counterclockwise Now use the arrow keys to select the desired parameter Press the Enter key to make changes to this value You can then change the value as...

Страница 12: ...Offline Click this button to disconnect from the meter Online Click this button to connect to the meter Peak Transfers all saved data that have been saved in the SAVE mode Ave Transfers all saved data...

Страница 13: ...en you open the programme you first see a list of graphs in the colours you have set Button Function Add Add a layout Modify Change a layout Del Delete a layout Run Starts the layout When you create o...

Страница 14: ...connects from the meter Online Establishes a connection to the meter Clear Deletes all displayed values UNIT Switches the unit Zero Resets the zero point To save the displayed data right click on the...

Страница 15: ...ral Business Terms which you can find here https www pce instruments com english terms 11 Disposal For the disposal of batteries in the EU the 2006 66 EC directive of the European Parliament applies D...

Страница 16: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...