ranges in which the measuring equipment can be used, as stipulated in the operating 
instructions, must always be adhered to. The usage of the equipment in areas which are exposed 
to high levels of contamination or corrosion should be avoided. In instances of major temperature 
fluctuations, the equipment must be given time to acclimatise before being used. 

 

The measuring equipment is only to be used for lifting and weighing of freely moving loads. A 
twisting or stressing of the load must not occur during the weighing process. The equipment must 
not be used for lifting people. It is prohibited for loads to be allowed to be dropped or be pulled 
along the ground or pulled at an angle. 

 

The maximum load as stipulated in the operating instructions [MAX] must never be exceeded 
(this also includes the maximum load stipulated for the crane or the heavy-lifting equipment being 
used in conjunction with the measuring equipment). 

 

Whilst operating the equipment any other potential hazardous areas, directly around the 
equipment should also be taken into consideration. When the equipment is in operation the 
hazardous area must be kept clear of any personnel. Directly beneath the load is of course an 
obvious hazardous area, but the danger of, for example a cable snapping, should also be taken 
into consideration, and a sufficient amount of safety distance should be observed. 

 

Servicing and examination 
 
Checks to be made before the use of the measuring equipment 

 
The equipment must be checked before the beginning of every workday. . In the course of the 
examination, the operator must ensure that, 

 

no deformations or other damages for example cracks are visible 

 

all the attachment parts are present and in good order and condition (for example safety splints 
etc.). 

 

the present complete system does not conceal any hazards (for example an incorrect assembly). 

 

there are no potential hazards within the vicinity of the operating area and if so the must be dealt 
with or rendered safe before operating the equipment. 

 

Regular inspection / Servicing 
 

After every 3 months or after 12,500 
measurements, depending on which comes first.  

 

- Check all parts for any excessive wear and 
tear.  

- Check all dimensions.  

Check housing for any signs of deformation or 

damage.  

Check all parts and ensure they are functioning 

correctly.  

 

After every 12 months or after 50,000 
measurements, depending on which comes first.  

 

- Check all load-bearing parts for example hairline 
cracks etc. Only trained personnel are to carry out 
maintenance.  

After every 5 years or 25,000 measurements, 
depending on which comes first.  

 

- All load-bearing parts must be exchanged.  

After every 10 years or 50,000 measurements, 
depending on which comes first.  

 

- If the measuring equipment has reached the end 
of its usable life, then it needs to be replaced.  

 

 
This user's handbook is published from PCE Instruments without any guarantee. 
 
We expressly point to our general guarantee terms, they can be found in our general terms of business. 
 
If you have any questions please contact PCE Instruments. 
 

 

Содержание PCE-CS

Страница 1: ...upiter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com ...

Страница 2: ...tion 6 4 1 Dimensions 6 4 2 Display 6 4 3 Remote control 7 4 4 Battery 7 5 Operation 8 5 1 Turn the scale on off 8 5 2 Zero function 8 5 3 Tare function 8 5 4 Hold function 8 5 5 Accumulation function 9 5 6 Battery voltage 9 5 7 Brightness 9 5 8 Measuring unit 9 6 Troubleshooting 10 7 Contact 11 7 1 PCE Instruments UK 11 7 2 PCE Americas 11 ...

Страница 3: ...there is a danger of explosion Please mind the maximum capacity of the scale at any point Do not exceed it In order to prevent potential hazardous situations when using heavy lifting equipment it is vital the manufacturer and the operator adhere to certain requirements When using the measuring equipment no risk must be posed to the operator The operator or the person responsible for operating the ...

Страница 4: ... to be made before the use of the measuring equipment The equipment must be checked before the beginning of every workday In the course of the examination the operator must ensure that no deformations or other damages for example cracks are visible all the attachment parts are present and in good order and condition for example safety splints etc the present complete system does not conceal any ha...

Страница 5: ...ltimate load 400 F S Battery type Fully sealed lead acid battery 6 V 1 Ah Battery life 50 hours Charging adaptor 9 V DC 1000 mA Remote control range 15 m Remote control battery 2 x 1 5 V AAA batteries Operating temperature 10 40 C Operating humidity 85 RH under 20 C Dimensions 264 x 206 x 745 mm Weight 30 kg 3 2 Delivery contents 1 x crane scale PCE CS 10000N incl Shackle hook and battery 1 x char...

Страница 6: ...1 Dimensions A mm B mm C mm D mm H mm R mm 124 206 48 264 745 45 4 2 Display LED display Charging indication Infrared receiver ON OFF button and stable indication Measuring unit indication Tare button and tare indication Max capacity ...

Страница 7: ...acid battery which can be replaced if it breaks down When fully loaded the crane scale can be operated for ca 50 hours If the display of the scale begins to blink it means that the battery voltage is low In this case please recharge the battery If the battery is not recharged the scale automatically shuts down after 1 2 hours If this happens recharge the battery before the next usage To charge the...

Страница 8: ... this is the case please contact our customer support To display the current zero point press SHIFT and ZERO on the remote at the same time 5 3 Tare function To use the tare function hang a weight on the scale wait for the reading to be stable and press the TARE button on the remote control or the TARE button on the scale itself The display now shows 0 and the tare indication is active If you alre...

Страница 9: ...e individual accumulations by using TARE and ZERO on the remote control Press SHIFT to return to normal weighing mode If you want to deactivate the accumulation function all accumulation data will be deleted press the CLR button on the remote control The display now shows Clr Press SHIFT to confirm the deletion or press CLR to cancel it 5 6 Battery voltage Press SHIFT and F1 on the remote at the s...

Страница 10: ... customer support Load cell cable damaged Contact customer support Out of calibration range Contact customer support Display shows excessive zero drift between measurements Electronics do not stabilize after turning on After turning on let scale hang for 3 5 minutes Scale was put on the ground for too long Scale should be hung Displayed weight differs from actual weight Scale was not zeroed before...

Страница 11: ...e contact PCE Instruments 7 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 7 2 PCE Americas By post PCE Americas Inc 711 Commerce Way Suite 8 Jupiter 33458 FL USA By phone 561 3209162 ...

Отзывы: