background image

Model Number

1102-05a

STRAIN GAGE LOAD CELL

Revision: E
ECN #: 43815

Performance

ENGLISH

SI 

Measurement Range

25 lb

111 N

[5]

Sensitivity(± 10 %)

2 mV/V

2 mV/V

[6]

Non-Linearity

≤ 0.05 % FS

≤ 0.05 % FS

Hysteresis

≤ 0.05 % FS

≤ 0.05 % FS

Non-Repeatability

≤ 0.02 %RO

≤ 0.02 %RO

Eccentric Load Sensitivity

≤ .25 %/in

≤ .25 %/25.4mm

Resonant Frequency

2.10 kHz

2.10 kHz

Creep(in 20 minutes)

≤ .025 %

≤ .025 %

Static Error Band

≤ .05 % FS

≤ .05 % FS

Environmental

Overload Limit

37.5 lb

167 N

Load Limit(Side Force, F

X

 or F

Y

)

25 lb

111 N

[3]

Load Limit

(Bending Moment, M

X

 or M

Y

)

25 in-lb

2.82 Nm

[3]

Load Limit

(Axial Torque, M

Z

)

35 in-lb

4 Nm

[3]

Temperature Range(Operating)

-65 to +200 °F

-54 to +93 °C

Temperature Range

(Compensated)

+70 to +170 °F

+21 to +77 °C

Temperature Effect on Output(Maximum)

± 0.0015 %Reading/°F

± 0.0027 %Reading/°C

[4]

Temperature Effect on Zero Balance(Maximum)

± 0.0008 %FS/°F

± 0.0015 %FS/°C

[4]

Electrical

Bridge Resistance

700 Ohm

700 Ohm

[1]

Excitation Voltage(Recommended)

10 VDC

10 VDC

[2]

Insulation Resistance

5x10

9

 Ohm

5x10

9

 Ohm

Zero Balance

≤ 1 % FS

≤ 1 % FS

Output Polarity

+Tension

+Tension

Physical

Size (Diameter x Height)

2.75 in x 1.50 in

69.9 mm x 38.1 mm

[7]

Weight

0.67 lb

304 g

Mounting Thread

1/4-28 Female

No Metric Equivalent

Housing Material

Painted Aluminum

Painted Aluminum

Sensing Element

Strain Gage

Strain Gage

Deflection at Full Scale Capacity

0.003 in

0.08 mm

Electrical Connector

PT02E-10-6P

PT02E-10-6P

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

NOTES:

[1]Nominal.
[2]Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
[3]Singularly applied, i.e. no other extraneous loads.
[4]Over compensated operating temperature range.
[5]FS - Full Scale.
[6]RO - Rated Output.
[7]See Outline Drawing 51277 for Complete Dimensions

OPTIONAL ACCESSORIES: 

Model 181-012A PT06A-10-6S(SR)
Model 8311-01-10A CABLE

PCB Load & Torque, Inc.
24350 Indoplex Circle
Farmington Hills, MI 48335
UNITED STATES
Phone: 866-684-7107
Fax: 716-684-0987
E-Mail: [email protected]
Web site: 
http://www.pcbloadtorque.com

OPTIONAL VERSIONS

Optional versions have identical specifications and accessories as listed for the standard 

model except where noted below. More than one option may be used.

Entered: AP

Engineer: PE

Sales: JC

Approved: JSD

Spec Number:

Date: 2/17/2015

Date: 2/17/2015

Date: 2/17/2015

Date: 2/17/2015

18331 

Содержание 1102-05A

Страница 1: ...stallation and Operating Manual For assistance with the operation of this product contact PCB Load Torque Inc Toll free 866 684 7107 24 hour SensorLine 716 684 0001 Fax 248 888 8266 E mail LTInfo pcbl...

Страница 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Страница 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...ng Considerations 3 6 0 CALIBRATION 3 6 1 Calibration Certificate Description 3 6 1 1 Measured Output 4 6 1 2 Hysteresis 4 6 1 3 Best Fit Output 4 6 1 4 Strain Gage Measurements 4 6 1 5 Shunt Calibrat...

Страница 7: ...ts 4 0 MECHANICAL INSTALLATION Loads applied to canister load cells must be even and centered Compensation linkages e g rod end bearing alignment couplers are recommended to help minimize load misalig...

Страница 8: ...nstrument or control system is grounded through its power cord Ground loops and measuring system wiring may result in unstable or noisy signals A simple test with a voltmeter connected between the pow...

Страница 9: ...eg of the bridge to apply the shunt resistor to for both tension and compression load simulation Typically tension is simulated by inserting the shunt resistor between the P and S connector leads Comp...

Страница 10: ...signal leads 9 Check bridge balance 10 Keep a record of your observations correct problems or contact PCB factory for assistance 10 0 CALIBRATION REPAIR SERVICES PCB Load Torque offers calibration an...

Страница 11: ...x 38 1 mm 7 Weight 0 67 lb 304 g Mounting Thread 1 4 28 Female No Metric Equivalent Housing Material Painted Aluminum Painted Aluminum Sensing Element Strain Gage Strain Gage Deflection at Full Scale...

Страница 12: ...FULL 1102 SERIES PT CONN CANNISTER LOAD CELL PTE 9 14 11 DECIMALS XX 01 XXX 005 DECIMALS X 0 3 XX 0 13 51277 PCB Load Torque Inc claims proprietary rights in the information disclosed hereon Neither i...

Отзывы: