background image

 

 
 

The information contained in this document supersedes all similar information that 
may be found elsewhere in this manual.

 

 

Total Customer Satisfaction

 – PCB 

Piezotronics guarantees Total Customer 
Satisfaction. If, at any time, for any 
reason, you are not completely satisfied 
with any PCB product, PCB will repair, 
replace, or exchange it at no charge. You 
may also choose to have your purchase 
price refunded in lieu of the repair, 
replacement, or exchange of the product. 
 

Service

 – Due to the sophisticated nature 

of the sensors and associated 
instrumentation provided by PCB 
Piezotronics, user servicing or repair is 
not recommended and, if attempted, may 
void the factory warranty. Routine 
maintenance, such as the cleaning of 
electrical connectors, housings, and 
mounting surfaces with solutions and 
techniques that will not harm the 
physical material of construction, is 
acceptable. Caution should be observed 
to insure that liquids are not permitted to 
migrate into devices that are not 
hermetically sealed. Such devices should 
only be wiped with a dampened cloth 
and never submerged or have liquids 
poured upon them. 
 

Repair

 – In the event that equipment 

becomes damaged or ceases to operate, 
arrangements should be made to return 
the equipment to PCB Piezotronics for 
repair. User servicing or repair is not 
recommended and, if attempted, may 
void the factory warranty. 
 

Calibration

 – Routine calibration of 

sensors and associated instrumentation is 

recommended as this helps build 
confidence in measurement accuracy and 
acquired data. Equipment calibration 
cycles are typically established by the 
users own quality regimen. When in 
doubt about a calibration cycle, a good 
“rule of thumb” is to recalibrate on an 
annual basis. It is also good practice to 
recalibrate after exposure to any severe 
temperature extreme, shock, load, or 
other environmental influence, or prior 
to any critical test. 
 
PCB Piezotronics maintains an ISO-
9001 certified metrology laboratory and 
offers calibration services, which are 
accredited by A2LA to ISO/IEC 17025, 
with full traceablility to N.I.S.T. In 
addition to the normally supplied 
calibration, special testing is also 
available, such as: sensitivity at elevated 
or cryogenic temperatures, phase 
response, extended high or low 
frequency response, extended range, leak 
testing, hydrostatic pressure testing, and 
others. For information on standard 
recalibration services or special testing, 
contact your local PCB Piezotronics 
distributor, sales representative, or 
factory customer service representative. 
 

Returning Equipment

 – 

Following 

these procedures will insure that your 
returned materials are handled in the 
most expedient manner

. Before returning 

any equipment to PCB Piezotronics, 
contact your local distributor, sales 
representative, or factory customer 
service representative to obtain a Return 

Warranty, Service, Repair, and 

Return Policies and Instructions 

Содержание Vibration Division ICP 086C01

Страница 1: ...on and Operating Manual For assistance with the operation of this product contact the Vibration Division of PCB Piezotronics Inc Division toll free 888 684 0015 24 hour SensorLineSM 716 684 0001 Fax 7...

Страница 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Страница 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Страница 4: ...ion with an accelerometer or the acoustic signature with a microphone Structures generally respond as 1 rigid or elastic bodies 2 finite elements lumped constant models and 3 distributed parameter mod...

Страница 5: ...tive frames tanks and bridges require an instrumented sledgehammer small structures like compressor blades often require mini hammers Some very large structures may require a massive mechanical ram in...

Страница 6: ...3 Models 086C02 086C03 086C04 Model 086D05...

Страница 7: ...4 Model 086D20 Model 086D50...

Страница 8: ...l Many FFT analyzer computer systems have ICP power supply built in The hammer is a single integral unit Laser welded construction of the sensor element insures reliable operation in adverse environme...

Страница 9: ...tions If meter pointer points in the yellow area look for open cables or connections Connect accelerometer s in similar manner referring to the appropriate operating guides for the accelerometer s and...

Страница 10: ...with lower stiffness require the use of the extender and soft impact tip to adequately excite low frequency resonances During testing occasionally check and tighten the electrical and mechanical conne...

Страница 11: ...having as a rigid body is a consistent 1 M ratio the force and the acceleration signals produces a calibration constant ideally 1 M for each discrete frequency The effects of a non modally tuned hamme...

Страница 12: ...y time for any reason you are not completely satisfied with any PCB product PCB will repair replace or exchange it at no charge You may also choose within the warranty period to have your purchase pri...

Страница 13: ......

Страница 14: ......

Отзывы: