background image

 

 

 

 
Manual 21354 Rev E 
ECN 50523 

 

 

 

 

 

 

 

 

PCB

业监视和测量设备

 - 

中国

RoHS2

公布表

 

PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 

部件名称

 

有害物

 

 (Pb) 

 

(Hg) 

 

(Cd) 

六价

 (Cr(VI)) 

多溴

联苯

 (PBB) 

多溴二苯

 (PBDE) 

住房

 

PCB

 

电气连接

 

压电晶

 

 

铁氟龙

 

 

厚膜基板

 

电线

 

电缆

 

塑料

 

 

铜合金

/

 

本表格依据

 SJ/T 11364 

规定编制

 

O

 

表示

该有害物质在该部件所有均质材料中的含量均在

 GB/T 26572 

规定的限量要求以下

 

X

 

表示

该有害物质至少在该部件的某一均质材料中的含量超出

 GB/T 26572 

规定的限量要求。

 

铅是欧洲

RoHS

指令

2011/65/ EU

附件三和附件四目前由于允

许的豁免

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHINA RoHS COMPLIANCE 

 

 

 

 

Содержание RHM240A02

Страница 1: ...ain Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E ma...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...model number s purchased The following pages give a brief description of the sensor series recommended mounting procedures operation and recommended calibration In addition to standard products PCB h...

Страница 7: ...ould remain on the connector to prevent contamination or damage For installation in dirty humid or rugged environments it is suggested that the connection be shielded against dust or moisture with shr...

Страница 8: ...ning to all ICP instrumentation Most of the signal conditioners manufactured by PCB have an adjustable current feature allowing a choice of input currents from 2 to 20 mA In general for lowest noise b...

Страница 9: ...ortant to DC couple the entire system and not just from the sensor to the signal conditioner The system time constant is determined by the shortest time constant in the system For this reason the sign...

Страница 10: ...allow this output voltage to decay 5 DTC s prior to making measurements in order to prevent baseline shift where an absolute zero is needed throughout entire monitoring process 10 0 MAINTENANCE The s...

Страница 11: ...ngth x Height 0 67 in x 1 81 in x 0 6 in 17 mm x 46 mm x 15 2 mm Weight 1 6 oz 45 gm 1 All specifications are at room temperature unless otherwise specified In the interest of constant product improve...

Страница 12: ...17 MJK 09 27 17 22493 PCB Piezotronics Inc claims proprietary rights in the information disclosed hereon Neither it nor any reproduction thereof will be disclosed to others without the written consent...

Отзывы: