PCB Piezotronics M1102-03A Скачать руководство пользователя страница 12

PIN A

+ EXC

PIN B

+SIG

PIN C

-SIG

PIN D

-EXC

PIN E

N/C

PIN F

N/C

WIRING CODE

1

1

2

2

3

3

4

4

A

A

B

B

DWG. NO.

SCALE:

SHEET

DRAWN

CHECKED

ENGINEER

TITLE

UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:

DIMENSIONS IN MILLIMETERS

[ IN BRACKETS ]

ANGLES

  

`

 .5 DEGREES

24350 Indoplex Circle, Farmington Hills,MI 48335
(716)  684-0001 E-MAIL:  [email protected]

DIMENSIONS  IN INCHES

ANGLES

  

`

 

.5 DEGREES

FILLETS AND RADII 

.015 MAX 

FILLETS AND RADII 

0.38 MAX

OUTLINE DRAWING

51277

1 OF 1

FULL

1102 SERIES, PT CONN.

CANNISTER LOAD CELL

PTE

9/14/11

DECIMALS     XX   ±.01

XXX   ±.005

DECIMALS    X   ± 0.3

XX   ± 0.13

5

1

2

7

7

PCB Load & Torque Inc. claims proprietary rights  in 
the  information disclosed hereon.  Neither it nor any 
reproduction thereof will be disclosed to others without
the written consent of PCB Load and Torque Inc.

REVISIONS

REV

DESCRIPTION

ECO

A

ADDED NOTE 1, WIRING CODE

38165

PT02E-10-6P RECEPTACLE

"THREAD" 

x

 .38 [9.6]

(STANDARD LOAD CELLS 1/4-28UNF-2B,
METRIC LOAD CELLS M6X1.0 6H)

.44 [11.2]

Ø

2.75 [69.9]

Ø

n

1.75 [44.5]

.86 [21.9]

1.34 [34.0]

.10 [2.5]

1.50 [38.1]

1.82 [46.2]

"THREAD" 

x

 .38 [9.6]

(STANDARD LOAD CELLS 1/4-28UNF-2B,

METRIC LOAD CELLS M6X1.0 6H)

JDM

01.08.12

ECB

01.09.12

Содержание M1102-03A

Страница 1: ...oad Cell Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...ng Considerations 3 6 0 CALIBRATION 3 6 1 Calibration Certificate Description 3 6 1 1 Measured Output 4 6 1 2 Hysteresis 4 6 1 3 Best Fit Output 4 6 1 4 Strain Gage Measurements 4 6 1 5 Shunt Calibrat...

Страница 7: ...ts 4 0 MECHANICAL INSTALLATION Loads applied to canister load cells must be even and centered Compensation linkages e g rod end bearing alignment couplers are recommended to help minimize load misalig...

Страница 8: ...nstrument or control system is grounded through its power cord Ground loops and measuring system wiring may result in unstable or noisy signals A simple test with a voltmeter connected between the pow...

Страница 9: ...eg of the bridge to apply the shunt resistor to for both tension and compression load simulation Typically tension is simulated by inserting the shunt resistor between the P and S connector leads Comp...

Страница 10: ...signal leads 9 Check bridge balance 10 Keep a record of your observations correct problems or contact PCB factory for assistance 10 0 CALIBRATION REPAIR SERVICES PCB Load Torque offers calibration an...

Страница 11: ...read No English Equivalent M6 x 1 6H Housing Material Painted Aluminum Painted Aluminum Sensing Element Strain Gage Strain Gage Deflection at Full Scale Capacity 0 003 in 0 08 mm Electrical Connector...

Страница 12: ...FULL 1102 SERIES PT CONN CANNISTER LOAD CELL PTE 9 14 11 DECIMALS XX 01 XXX 005 DECIMALS X 0 3 XX 0 13 51277 PCB Load Torque Inc claims proprietary rights in the information disclosed hereon Neither i...

Отзывы: