Model Number

M1102-03A

STRAIN GAGE LOAD CELL

Revision: D
ECN #: 43815

Performance

ENGLISH

SI 

Measurement Range

225 lb

1000 N

[5]

Sensitivity(± 10 %)

2 mV/V

2 mV/V

[6]

Non-Linearity

≤ 0.05 % FS

≤ 0.05 % FS

Hysteresis

≤ 0.05 % FS

≤ 0.05 % FS

Non-Repeatability

≤ 0.02 % FS

≤ 0.02 % FS

Resonant Frequency

5.4 kHz

5.4 kHz

Environmental

Overload Limit

338 lb

1500 N

Load Limit(Side Force, F

X

 or F

Y

)

225 lb

1000 N

[3]

Load Limit

(Bending Moment, M

X

 or M

Y

)

225 in-lb

25.4 Nm

[3]

Load Limit

(Axial Torque, M

Z

)

65 in-lb

7 Nm

[3]

Temperature Range(Operating)

-65 to +200 °F

-54 to +93 °C

Temperature Range

(Compensated)

+70 to +170 °F

+21 to +77 °C

Temperature Effect on Output(Maximum)

± 0.002 %Reading/°F

± 0.0036 %Reading/°C

[4]

Temperature Effect on Zero Balance(Maximum)

± 0.002 %FS/°F

± 0.0036 %FS/°C

[4]

Electrical

Bridge Resistance

700 Ohm

700 Ohm

[1]

Excitation Voltage(Recommended)

10 VDC

10 VDC

[2]

Insulation Resistance

>5x10

9

 Ohm

>5x10

9

 Ohm

Zero Balance

≤ 1 % FS

≤ 1 % FS

Output Polarity

+Tension

+Tension

Physical

Size (Diameter x Height)

2.75 in x 1.5 in

69.9 mm x 38.1 mm

Weight

0.67 lb

304 g

Mounting Thread

No English Equivalent

M6 x 1-6H

Housing Material

Painted Aluminum

Painted Aluminum

Sensing Element

Strain Gage

Strain Gage

Deflection at Full Scale Capacity

0.003 in

0.08 mm

Electrical Connector

PT02E-10-6P

PT02E-10-6P

Electrical Connection Position

Side

Side

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

NOTES:

[1]Nominal.
[2]Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
[3]Singularly applied, i.e. no other extraneous loads.
[4]Over compensated operating temperature range.
[5]FS - Full Scale.
[6]RO - Rated Output.

OPTIONAL ACCESSORIES: 

Model 181-012A PT06A-10-6S(SR)
Model 8311-01-10A CABLE

PCB Load & Torque, Inc.
24350 Indoplex Circle
Farmington Hills, MI 48335
UNITED STATES

Phone: 866-684-7107
Fax: 716-684-0987
E-Mail: [email protected]
Web site: 
http://www.pcbloadtorque.com

OPTIONAL VERSIONS

Optional versions have identical specifications and accessories as listed for the standard 

model except where noted below. More than one option may be used.

Entered: AP

Engineer: PE

Sales: JC

Approved: JSD

Spec Number:

Date: 2/17/2015

Date: 2/17/2015

Date: 2/17/2015

Date: 2/17/2015

48118 

Содержание M1102-03A

Страница 1: ...oad Cell Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...ng Considerations 3 6 0 CALIBRATION 3 6 1 Calibration Certificate Description 3 6 1 1 Measured Output 4 6 1 2 Hysteresis 4 6 1 3 Best Fit Output 4 6 1 4 Strain Gage Measurements 4 6 1 5 Shunt Calibrat...

Страница 7: ...ts 4 0 MECHANICAL INSTALLATION Loads applied to canister load cells must be even and centered Compensation linkages e g rod end bearing alignment couplers are recommended to help minimize load misalig...

Страница 8: ...nstrument or control system is grounded through its power cord Ground loops and measuring system wiring may result in unstable or noisy signals A simple test with a voltmeter connected between the pow...

Страница 9: ...eg of the bridge to apply the shunt resistor to for both tension and compression load simulation Typically tension is simulated by inserting the shunt resistor between the P and S connector leads Comp...

Страница 10: ...signal leads 9 Check bridge balance 10 Keep a record of your observations correct problems or contact PCB factory for assistance 10 0 CALIBRATION REPAIR SERVICES PCB Load Torque offers calibration an...

Страница 11: ...read No English Equivalent M6 x 1 6H Housing Material Painted Aluminum Painted Aluminum Sensing Element Strain Gage Strain Gage Deflection at Full Scale Capacity 0 003 in 0 08 mm Electrical Connector...

Страница 12: ...FULL 1102 SERIES PT CONN CANNISTER LOAD CELL PTE 9 14 11 DECIMALS XX 01 XXX 005 DECIMALS X 0 3 XX 0 13 51277 PCB Load Torque Inc claims proprietary rights in the information disclosed hereon Neither i...

Отзывы: