background image

 

 

 

 
Manual 21354 Rev E 
ECN 50523 

 

 

Component Name 

Hazardous Substances 

Lead (Pb)  Mercury (Hg) 

Cadmium (Cd) 

Chromium VI 
Compounds 
(Cr(VI)) 

Polybrominated 
Biphenyls (PBB) 

Polybrominated 
Diphenyl Ethers 
(PBDE) 

Housing 

PCB Board 

Electrical Connectors 

Piezoelectric Crystals 

Epoxy 

Teflon 

Electronics 

Thick Film Substrate 

Wires 

Cables 

Plastic 

Solder 

Copper Alloy/Brass 

This table is prepared in accordance with the provisions of SJ/T 11364. 
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit 
requirement of GB/T 26572. 

X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit 
requirement of GB/T 26572. 
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU. 

Содержание IMI SENSORS HT640B71

Страница 1: ...rial Vibration Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 68...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...640 641 645 646 B7 Series Industrial 4 20mA Sensor Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1...

Страница 7: ...Contents Introduction Page 3 General Features Dimension Drawing Page 4 Operation and Wiring Page 5 Standard Wiring Taking Measurements RV Option TO Option EP Option ESD Sensitivity Page 10 Warranty S...

Страница 8: ...ies Please refer to specific specification sheets for further details General Features Imbedded Piezoelectric Accelerometer for improved accuracy and frequency response Vibration range can be in Accel...

Страница 9: ...PAGE 4 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Dimension Drawing Inch mm 1 NPT 2 57 1 4 NPT MOUNTING THREAD 3 65 1 500 1 375...

Страница 10: ...A loop Attach the positive input from the power supply to Pin 2 and the negative input from the power supply to Pin 3 Figure 1 wiring standard connection Figure 2 wiring loop powered Figure 3 wiring l...

Страница 11: ...ps pk 0 0 ips pk 8 00 0 125 ips pk 0 25 ips pk 0 5 ips pk 12 0 0 25 ips pk 0 5 ips pk 1 0 ips pk 15 75 0 37 ips pk 0 73 ips pk 1 47 ips pk 20 0 5 ips pk 1 0 ips pk 2 0 ips pk Measured mA 641BX0 641BX1...

Страница 12: ...maximum amplitude of 15 g pk Data collectors or analyzers can use this vibration signal for further analysis Figure 3 RV wiring Note The Acceleration Signal Negative has to be isolated from any ground...

Страница 13: ...ture range is from 40 C to 125 C with an overall accuracy of 5 FSO The imbedded temperature sensor monitors the environment internal to the sensor housing and is situated at approximately mid level Fi...

Страница 14: ...The EP option includes an Explosion Proof capped elbow for applications in rigid or IMC conduit systems where space is limited and access is needed for pulling conductors or maintenance Standard cond...

Страница 15: ...ischarge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a ru...

Страница 16: ...ior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proce...

Страница 17: ...ed IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforeseen problems o...

Страница 18: ......

Страница 19: ......

Отзывы: