Magnetic Mount Procedure 

Magnetic mounting provides a convenient means for making portable measurements and is commonly used for 

machinery monitoring and other portable or tending applications. 

Note:

 The correct magnet choice and an adequately prepared mounting surface is critical for obtaining reliable 

measurements, especially at high frequencies. Poot installations can cause as much as a 50% drop in the sensor 

frequency range. 

 

Not every magnet is suitable for all applications. For example, rare earth magnets are commonly used 

because of their high strength. Flat magners work well on smooth, flat surfaces, while dual-rail magnets 

are required for curved surfaces. In the case o non-magnetic or rough surfaces, it is recommended that 

the user first weld, epocy or otherwise adhere a stell mounting pad to the test surface. This provides a 

smooth and repeatable location for mounting. 

Figure 9

– magnet types  

 

 

STEP 1

 After choosing the correct magnet type, inspect the unit, verifying that the mounting surfaces are flat and 

smooth. 

 

STEP 2 

Stud- mount the accelerometer to the appropriate magnet according to the guidelines set forth in Steps 2 

and 3 of the Standard Stud Mount Procedure. 

 

STEP 3 

Prepare a smooth, flat mounting surface. A minimum surface finish of 63 µin [0.0016 mm] generally 

works best. After cleaning the surface and checking for burrs, wipe on a light film of silicone grease, machine oil 

or similar-type coupling fluid. 

STEP 4 

Mount the magnet/sensor assembly to the prepared te

st surface by gently ‘rocking” or “sliding” it into 

place. 

Note:

 Magnetically mounting accelerometers carelessly as the potential to generate very high ( and very 

damaging) g levels. To prevent damage, install the assembly gently. If unsure, please contact the factory for 

assistance.   

Содержание IMI SENSORS 640B06

Страница 1: ...ial Vibration Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684...

Страница 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Страница 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...trial 4 20mA Sensor Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI MANUAL NUMBER 2531...

Страница 7: ...n and Wiring Page 5 Standard Wiring Taking Measurements RV Option RVVO Option TO Option Installation Page 9 Direct Adhesive Mount Standard Stud Mount Adhesive Stud Mount Magnetic Mount ESD Sensitivity...

Страница 8: ...further details General Features Imbedded Piezoelectric Accelerometer for improved accuracy and frequency response Vibration range can be in Acceleration or Velocity Allows for continuous vibration m...

Страница 9: ...PAGE 4 Dimension Drawing...

Страница 10: ...ply to Pin B or Blue Wire of the sensor Figure 1 wiring loop powered Figure 2 wiring loop powered DC source If using a standard DC power supply install either an ammeter and or load resistor in line w...

Страница 11: ...pk 12 0 0 25 ips pk 0 5 ips pk 1 0 ips pk 15 75 0 37 ips pk 0 73 ips pk 1 47 ips pk 20 0 5 ips pk 1 0 ips pk 2 0 ips pk Measured mA 641BX0 641BX1 641BX2 4 00 0 0 ips rms 0 0 ips rms 0 0 ips rms 8 00 0...

Страница 12: ...option which integrates the signal to a value of 100 mV IPS 20 Figure 3 RV and RVVO wiring For integral cable sensors RED 4 20mA Positive BLACK 4 20mA Negative same as green GREEN RV and RVVO negativ...

Страница 13: ...e environment internal to the sensor housing and is situated at approximately mid level Figure 4 TO wiring For integral cable sensors RED 4 20mA Vibration Positive BLACK 4 20mA Vibration Negative GREE...

Страница 14: ...e 645 646 series because of the increased frequency response Direct Adhesive Mount Procedure For restrictions of space or for convenience most sensors with the exception of integral stud models can be...

Страница 15: ...to properly prepare the machine surface consider using an adhesive mounting pad as a possible alternative Inspect the area checking that there are no burrs or other foreign particles interfering with...

Страница 16: ...requency response This method involves attaching a base to the machine surface then securing the snesor to the base This alows for easy removal of the accelerometer STEP 1 Prepare a smooth flat mounti...

Страница 17: ...adhere a stell mounting pad to the test surface This provides a smooth and repeatable location for mounting Figure 9 magnet types STEP 1 After choosing the correct magnet type inspect the unit verifyi...

Страница 18: ...rical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a rug Any movement through air Th...

Страница 19: ...ATION RMA NUMBER Please have information available such as model and serial number Also to insure efficient service provide a written description of the symptoms and problems with the equipment to a l...

Страница 20: ...ctrical Connections Pin A 4 20 mA Pos 4 20 mA Pos Electrical Connections Pin B 4 20 mA Neg 4 20 mA Neg 5 All specifications are at room temperature unless otherwise specified In the interest of consta...

Страница 21: ......

Отзывы: