background image

Model Number

EX619A11

CHARGE OUTPUT ACCELEROMETER

Revision: NR

ECN #: 44641

Performance

ENGLISH

SI 

Sensitivity(± 5 %)

50 pC/g

5.1 pC/(m/s²)

Measurement Range

± 500 g pk

± 4905 m/s² pk

Frequency Range(± 5 %)

3000 Hz

3000 Hz

[2]

Frequency Range

(+10 %)

5000 Hz

5000 Hz

[2]

Resonant Frequency

>18 kHz

>18 kHz

[1]

Non-Linearity

 1 %

 1 %

[3]

Transverse Sensitivity

 5 %

 5 %

[4]

Environmental

Overload Limit(Shock)

± 2000 g pk

± 19,620 m/s² pk

Temperature Range

-65 to +900 °F

-54 to +482 °C

Temperature Response

See Graph

See Graph

[1]

Temperature Response

See Graph

See Graph

Temperature Response

See Graph

See Graph

Base Strain Sensitivity

 0.033 g/µ

ε

 .32 (m/s²)/µ

ε

Electrical

Capacitance(Pin to Pin)

1525 pF

1525 pF

[1]

Capacitance

(Pin to Case)

250 pF

250 pF

[1]

Insulation Resistance(Pin to Case 70° F)

>10

9

 Ohm

>10

9

 Ohm

Insulation Resistance

(Pin to Pin 70° F)

>10

9

 Ohm

>10

9

 Ohm

Insulation Resistance

(Pin to Pin 900° F)

>100 kohm

>100 kohm

Output Polarity

Differential

Differential

Physical

Sensing Element

Ceramic

Ceramic

Sensing Geometry

Compression

Compression

Housing Material

Inconel

Inconel

Sealing

Hermetic

Hermetic

Size (Height x Length x Width)

1.49 in x 1.63 in x 1.63 in

38 mm x 41.4 mm x 41.4 mm

Weight(with cable)

19.4 oz

550 gm

[1]

Electrical Connector

2-Pin MIL-C-5015

2-Pin MIL-C-5015

Electrical Connection Position

Side

Side

Cable Length

7 ft

2.1 m

Cable Type

MI Hardline Cable

MI Hardline Cable

Mounting

Through Holes (4)

Through Holes (4)

[5]

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

ICP

®

 is a registered trademark of PCB Group, Inc. 

NOTES:

[1]Typical.
[2]Low frequency response is determined by external signal conditioning electronics.
[3]Zero-based, least-squares, straight line method.

[4]Transverse sensitivity is typically 

 3%.

[5]See PCB Declaration of Conformance PS141 for details.

SUPPLIED ACCESSORIES: 

Model 62177-01 1/4-28 x 1 1/4in long (1)

Model ICS-1 NIST-traceable single-axis amplitude response calibration from 600 cpm (10 Hz) to 
upper 5% frequency

3425 Walden Avenue, Depew, NY 14043

Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]

OPTIONAL VERSIONS

Optional versions have identical specifications and accessories as listed for the standard 

model except where noted below. More than one option may be used.

Entered: JM

Engineer: JJD

Sales: EGY

Approved: NJF

Spec Number:

Date: 9/30/2015

Date: 9/30/2015

Date: 9/30/2015

Date: 9/30/2015

62610 

Содержание EX619A11

Страница 1: ...elerometer Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E ma...

Страница 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Страница 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...ODE ACCELEROMETERS SPECIFICATION SHEET INSTALLATION DRAWING AND CALIBRATION INFORMATION ENCLOSED PCB ASSUMES NO RESPONSIBILITY FOR DAMAGE CAUSED TO THIS PRODUCT AS A RESULT OF PROCEDURES THAT ARE INCO...

Страница 7: ...Line Differential Charge Amplifier 4 3 INSTALLATION OVERVIEW 5 3 1 Equipment Inspection 5 3 2 Polarity Test 5 3 3 Sensor Location 5 3 4 Mounting Sensor 5 3 5 Route Mineral Insulated Hardline Cable 6...

Страница 8: ...prior to being analyzed by a readout or recording device The absence of built in electronics permits operation to elevated temperatures of 500 F 260 C for most models or up to 1300 F 700 C for specia...

Страница 9: ...high temperature 500 F charge mode applications use mineral insulated MI hardline Keep cable clean to maintain insulation resistance and good low frequency response 2 4 Hardline Connection Type 2 4 1...

Страница 10: ...goes negative the wiring is reversed contact PCB for technical support FIGURE 1 3 3 Sensor Location Characteristics like location ruggedness amplitude range accessibility temperature and portability...

Страница 11: ...act surface Figure 2 Mounting Surface Preparation STEP 3 Wipe the mounting surface clean prior to installation STEP 4 Place the sensor on the mounting surface and attach with mounting bolts and tighte...

Страница 12: ...um Bending Radius Total d r 1 0 125 3 2 mm 0 60 16 mm 20 0 125 3 2 mm 2 0 50 mm 3 5 3 Clamp Cable To minimize triboelectric motion induced noise from the cable interfering with the sensors high impeda...

Страница 13: ...each element is connected allow a few minutes for the system to thermally stabilize Place the switch on the charge amplifier in the OPERATE position and proceed with the measurement It is often conve...

Страница 14: ...f a typical direct coupled charge amplifier where Rf Feedback resistor ohms Ri Input leakage resistance ohms Eo Steady state output voltage volts ei Offset voltage FET leakage volts Cf Feedback capaci...

Страница 15: ...en the offending sensor or low impedance hardline and the input Figure 5 2 Piezoelectric System Block Diagram Figure 5 2 illustrates a block diagram of the piezo electric system where Ct Shunt capacit...

Страница 16: ...s i o C R 16 f To avoid compromise of the low frequency response established by the charge amplifier parameters and illustrated by Equation 2 the product of RiCs should be several orders of magnitude...

Страница 17: ...rating range may temporarily or permanently affect the sensor This change manifests itself in a variety of ways including a shift of the sensor resonance due to a cracked crystal or a temporary loss o...

Страница 18: ...ognized standards laboratory are designed for stability as well as configured to accept a test accelerometer By mounting a test accelerometer to the reference standard and then connecting this combina...

Страница 19: ...are stress relieved by first routing them to the shaker head securing them with tape or cable ties then routing them to a nearby stationary location This reduces cable motion which is especially impor...

Страница 20: ...tuds Figure 5 Stud Mounting Understand Back to Back Calibration limitations Do not expect the uncertainty of calibration to be any better than 2 In fact the uncertainty may be as high as 3 or 4 for fr...

Страница 21: ...x 41 4 mm x 41 4 mm Weight with cable 19 4 oz 550 gm 1 Electrical Connector 2 Pin MIL C 5015 2 Pin MIL C 5015 Electrical Connection Position Side Side Cable Length 7 ft 2 1 m Cable Type MI Hardline C...

Страница 22: ...EROMETER DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 BB 9 30 15 ECB 9 30 15 JJD 9 30 15 bbehringer 16 19 9 30 2015 59256 PCB Piezotronics Inc claims proprietary rights in the information disclosed h...

Страница 23: ...DWG 62689 REV NR DIN 44641...

Страница 24: ...DWG 62689 REV NR DIN 44641...

Страница 25: ...DWG 62689 REV NR DIN 44641...

Страница 26: ...DWG 62690 REV NR DIN 44641...

Страница 27: ...DWG 62690 REV NR DIN 44641...

Страница 28: ...DWG 62690 REV NR DIN 44641...

Страница 29: ...44641 SCHEDULE DRAWING NO MODIFICATIONS PERMITTED WITHOUT REFERENCE TO THE NOTIFIED BODY Ci AND Li BASED ON CABLE WITH 20 pF ft AND 3 H ft WITH A MAXIMUM CABLE LENGTH OF 100ft Ci AND Li WILL BE DECREA...

Страница 30: ...ER SHALL INSURE THAT THE TRANSDUCER MOUNTING STRUCTURE IS AT THE SAME GROUNDING POTENTIAL AS THE BARRIER GROUND TOTAL EARTH LOOP IMPEDANCE SHALL BE LESS THAN ONE OHM ENTITY PARAMETERS Ui 30 V Ii 130 m...

Страница 31: ...nly Zafar Iqbal Issued by Zafar Iqbal PRODUCTS CLASS 2258 03 PROCESS CONTROL EQUIPMENT Intrinsically Safe and Non Incendive Systems For Hazardous Locations CLASS 2258 83 PROCESS CONTROL EQUIPMENT Intr...

Страница 32: ...ng to Article 501 16 of the NEC CLASS2258 04 PROCESS CONTROL EQUIPMENT Intrinsically Safe Entity For Hazardous Locations CLASS2258 84 PROCESS CONTROL EQUIPMENT Intrinsically Safe Entity For Hazardous...

Страница 33: ...must be bonded to ground according to Section 18 182 of the CEC Part 1 For US Installations sensor case must be bonded to ground according to Article 501 16 of the NEC APPLICABLE REQUIREMENTS CAN CSA...

Страница 34: ...and III Division 1 Hazardous Locations FM Std No 3600 1998 Electrical Equipment for Use in Hazardous Classified Locations General Requirements ANSI ISA 12 12 01 2012 Nonincendive Electrical Equipment...

Страница 35: ...are eligible to be marked in accordance with the referenced Certificate Product Certification History Project Date Description 70028914 Sep 23 2015 New CSA C US certification for model EX619XYY MNNNZ...

Отзывы: