background image

 

 

 

 
Manual 21354 Rev E 
ECN 50523 

 

 

 

 

 

 

 

 

PCB

业监视和测量设备

 - 

中国

RoHS2

公布表

 

PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 

部件名称

 

有害物

 

 (Pb) 

 

(Hg) 

 

(Cd) 

六价

 (Cr(VI)) 

多溴

联苯

 (PBB) 

多溴二苯

 (PBDE) 

住房

 

PCB

 

电气连接

 

压电晶

 

 

铁氟龙

 

 

厚膜基板

 

电线

 

电缆

 

塑料

 

 

铜合金

/

 

本表格依据

 SJ/T 11364 

规定编制

 

O

 

表示

该有害物质在该部件所有均质材料中的含量均在

 GB/T 26572 

规定的限量要求以下

 

X

 

表示

该有害物质至少在该部件的某一均质材料中的含量超出

 GB/T 26572 

规定的限量要求。

 

铅是欧洲

RoHS

指令

2011/65/ EU

附件三和附件四目前由于允

许的豁免

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHINA RoHS COMPLIANCE 

 

 

 

 

Содержание EX357E92

Страница 1: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 2: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 3: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 4: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 5: ...F 482 C and extreme application up to 100 F 650 C for UHT 12 These accelerometers are ideal for structural testing machine monitoring and vehicular shock and vibration measurement tasks where high tem...

Страница 6: ...urface consider adhesive mounting as a possible alternative Inspect the area checking that there are no burrs or other foreign particles interfering with the contact surface STEP 2 Wipe clean the moun...

Страница 7: ...or most applications It is generally used only for machinery monitoring and other portable trending applications Both the accuracy and repeatability at low 5 Hz and high frequency 1 kHz ranges are que...

Страница 8: ...o a precise sensitivity such as 10 0 or 100 0 mV g for ease of data analysis This is accomplished with most PCB laboratory charge amplifiers and some miniature in line units as well For fixed sensitiv...

Страница 9: ...dure themselves While this may result in both a savings of time and money it has also been attributed to incorrect readings and costly errors Therefore in an effort to prevent the common mistakes asso...

Страница 10: ...Figure 12 Typical Calibration Set Up Adhesively mounted sensors use similar practices However in this case a small portion of quick bonding gel or similar temporary adhesive is used to attach the tes...

Страница 11: ...s Incorrect Understand Back to Back Calibration limitations Do not expect the uncertainty of calibration to be any better than 2 In fact the uncertainty may be as high as 3 or 4 for frequencies 10 Hz...

Страница 12: ...Hermetic Welded Hermetic Size Height x Length x Width 56 in x 95 in x 56 in 14 2 mm x 24 1 mm x 14 2 mm Weight without cable 1 6 oz 45 gm 1 Electrical Connector Integral Hardline Cable Integral Hardli...

Страница 13: ...eof will be disclosed to others without the written consent of PCB Piezotronics Inc REVISIONS REV DESCRIPTION DIN A EX357E92 WAS 357E92 49874 56 14 2 28 7 1 95 24 1 23 5 7 120 0 4 0 3048 102 72 18 2 1...

Отзывы: