background image

Model Number 

682B03 

 

ICP

®

 VIBRATION TRANSMITTER 

Revision A 
ECN #: 32835 

 

 

Performance ENGLISH 

SI 

       

Channels   

       

Input Signal   (Vibration) 

±100 mV/g 

±10.2 mV/(m/s²) 

[4] 

Input Signal   (Temperature) 

0 to 1.2 VDC 

0 to 1.2 VDC 

[5] 

Output Signal   (DC Vibration) 

4 to 20 mA 

4 to 20 mA 

[6] 

Output Signal   (DC Vibration) 

0 to 5 VDC 

0 to 5 VDC 

[7][3] 

Output Signal   (DC Vibration) 

0 to 10 VDC 

0 to 10 VDC 

[7][3] 

Output Signal   (Temperature) 

4 to 20 mA 

4 to 20 mA 

[5] 

Output Signal   (±0.01 %)  (AC Vibration) 

100 mV/g 

10.2 mV/(m/s²) 

[8] 

Frequency Range   (-3 dB)  (Acceleration) 

180 to 600000 cpm 

3 to 10k Hz 

[9][10][1

1] 

Frequency Range   (-3 dB)  (Velocity) 

210 to 600000 cpm 

3.5 to 10k Hz 

[9][10][1

1] 

Frequency Range   (-3 dB)  (Displacement) 

210 to 60000 cpm 

3.5 to 1000 Hz 

[9][12][1

0] 

Output Range   (DC Acceleration) 

0 to 5.00 g pk or 

rms 

0 to 49.03 m/s

pk or 

rms 

[13][4][3

Output Range   (DC Acceleration) 

0 to 10.00 g pk or 

rms 

0 to 98.06 m/s

pk or 

rms 

[13][4][3

Output Range   (DC Acceleration) 

0 to 20.00 g pk or 

rms 

0 to 196.12 m/s

pk or 

rms 

[13][4][3

Output Range   (DC Velocity) 

0 to 0.5 in/sec pk 

or rms 

0 to 12.7 mm/s pk or 

rms 

[13][4][3

Output Range   (DC Velocity) 

0 to 1.00 in/sec pk 

or rms 

0 to 25.4 mm/s pk or 

rms 

[13][4][3

Output Range   (DC Velocity) 

0 to 2.00 in/sec pk 

or rms 

0 to 50.8 mm/s pk or 

rms 

[13][4][3

Output Range   (DC Displacement) 

0 to 10.0 mil pk - 

pk 

0 to 0.254 mm pk - pk 

[13][4][3

Output Range   (DC Displacement) 

0 to 20.0 mil pk - 

pk 

0 to 0.508 mm pk - pk 

[13][4][3

Output Range   (DC Displacement) 

0 to 40.0 mil pk - 

pk 

0 to 1.02 mm pk - pk 

[13][4][3

Environmental 

 

 

 

Temperature Range   (Operating) 

32 to 158 °F 

0 to 70 °C 

       

Temperature Range   (Storage) 

-40 to 257 °F 

-40 to 125 °C 

       

Humidity Range   (Non-Condensing) 

0 to 95 % 

0 to 95 % 

       

Electrical 

 

 

 

Power Required   

DC power 

DC power 

       

DC Power   

23 to 25 VDC 

23 to 25 VDC 

       

DC Power   (maximum) 

100 mA 

100 mA 

       

Settling Time   

<2 min 

<2 min 

       

Excitation Voltage   (delivered to sensor) 

17 to 19 VDC 

17 to 19 VDC 

[1][2] 

Constant Current Excitation   (delivered to 
sensor) 

3 to 5 mA 

3 to 5 mA 

[1][2] 

Output Span   (±5.0 %)  (DC Vibration 
Current Output) 

16 mA 

16 mA 

       

Output Span   (±5.0 %)  (Temperature 
Output) 

16 mA 

16 mA 

       

Output Span   (±5.0 %)  (DC Vibration 
Voltage Output) 

5 or 10 VDC 

5 or 10 VDC 

[3] 

Physical 

 

 

 

Electrical Connector   (input/output) Removable 

Screw 

Terminals 

  Removable Screw 

Terminals 

       

Electrical Connector   (raw vibration output) 

BNC Jack 

  BNC Jack 

       

Housing Material   

Polyamide 

Polyamide 

       

Optional Versions 

(Optional versions have identical specifications and accessories as listed 

for standard model except where noted below. More than one option maybe used.) 
 

Notes

 

[1] Jumper selectable for 18 VDC regulated, 24 VDC power supply voltage or ICP® 
sensor excitation disabled 
[2] 4 mA constant current diode is internal to 9330VT 
[3] Internal Dip switch selectable 
[4] Output measurement range is based upon input from 100 mV/g ICP® 
accelerometer and will be scaled inversely proportional to any percentage deviation of 
this input. 
[5] Requires use of accelerometer with "TO" temperature output option. 
[6] Output current voltage will fluctuate at frequencies below 5 Hz. 
[7] Factory set, 0-5 VDC. 
[8] Achieved with 100 mV/g ICP® accelerometer input. 
[9] Attenuation is -40 dB/decade. 
[10] The low frequency tolerance is accurate within ± 0.5 Hz of the specified 
frequency. 
[11] The high frequency tolerance is accurate within ± 0.5 kHz of the specified 
frequency. 
[12] Maximum 1,000 Hz for displacement. 
[13] Factory set, 1  in/sec peak. 
[14] See PCB Declaration of Conformance PS051 for details. 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Entered: LLH 

Engineer: NJF 

Sales: EGY 

Approved: MRS 

Spec Number: 

Date: 
04/29/2010 

Date: 
04/24/2010 

Date: 
04/24/2010 

Date: 
07/08/2010 

40536 

 

 

 

3425 Walden Avenue 
Depew, NY  14043 
UNITED STATES 
Phone: 716-684-0003 
Fax: 716-684-3823 
E-mail: [email protected] 
Web site: www.imi-sensors.com 

 

 

Содержание 682B03

Страница 1: ...itter Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail im...

Страница 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Страница 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Страница 4: ...Series 4 20mA Din Rail ICP Signal Conditioner Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800...

Страница 5: ...ORING Table of Contents Introduction Page 3 General Features Installation and Wiring Page 6 Configuring the 682BX3 Page 10 ESD Sensitivity Page 13 Ordering Information Page 14 Warranty Servicing Warra...

Страница 6: ...oner Optional 500Vdc Input to Output Electrical Isolation Selectable 24Vdc Unregulated 18Vdc regulated 4mA excitation to power sensor 4 20mA Output Signals for Vibration and Temperature Selectable 0 5...

Страница 7: ...stallation The 682 Series is designed to be mounted on a 35mm Din Rail Do not install in a harsh area where it can be exposed to cleaning fluids or machine oils IMI Sensors recommends mounting the 682...

Страница 8: ...closure in either the up or down direction terminate the wire in the correct location Do not exceed a torque of 0 5Nm Re install the terminal block This easy to assemble connection method allows devic...

Страница 9: ...7 to 8 Pin 7 Temperature Sensor Pin 8 Temperature Sensor ICP Accelerometer Raw Vibration RV Pins 9 to 10 and BNC Jack Pin 9 RV Pin 10 RV 4 to 20mA Temperature Output Pins 11 to 12 Pin 11 4 to 20mA Te...

Страница 10: ...D INSTRUMENTATION FOR MACHINE CONDITION MONITORING Typical Wiring Diagram To Maintain Conformance Earth Ground Power Supply Common and I O Shields must be connected together 682 Series Signal Conditio...

Страница 11: ...gnal conditioner for various sensor and vibration ranges The Filter Modules are installed to set the High and Low cutoff frequencies The Jumper selects unregulated regulated or no ICP power to the acc...

Страница 12: ...FF OFF ON ON OFF OFF OFF ON OFF ON OFF 2 0 in sec RMS OFF OFF ON ON OFF OFF ON OFF ON OFF OFF 2 0 in sec Peak OFF OFF ON ON OFF OFF OFF ON ON OFF OFF 10 mils p p OFF OFF OFF OFF ON ON OFF OFF OFF OFF...

Страница 13: ...PAGE 10 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Sensor Power Jumper Configuration 682 Series Signal Conditioner...

Страница 14: ...ESD sensitivity Cables can kill your equipment High voltage electrostatic discharge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer...

Страница 15: ...682A X 3 Frequency Response Isolation 0 3Hz to 10kHz Standard 1 3Hz to 1kHz 2 10Hz to 10kHz 3 10Hz to 1kHz 4 3Hz to 10kHz with 500Vdc I O Isolation 5 3Hz to 1kHz with 500Vdc I O Isolation 6 10Hz to 1...

Страница 16: ...ior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proce...

Страница 17: ...price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforese...

Страница 18: ...r maximum 100 mA 100 mA Settling Time 2 min 2 min Excitation Voltage delivered to sensor 17 to 19 VDC 17 to 19 VDC 1 2 Constant Current Excitation delivered to sensor 3 to 5 mA 3 to 5 mA 1 2 Output Sp...

Страница 19: ...Fault Red LED Red LED Status Indicator Measurement Mode Acceleration Green LED Green LED Status Indicator Measurement Mode Velocity Green LED Green LED Status Indicator Measurement Mode Displacement...