Warning 1 – ESD sensitivity 

 

The power supply/signal conditioner should not be opened by anyone other than qualified service 

personnel.  This product is intended for use by qualified personnel who recognize shock hazards and are familiar 

with the safety precautions required to avoid injury. 

Warning 2 – ESD sensitivity 

This equipment is designed with user safety in mind; however, the protection provided by the equipment may be 

impaired if the equipment is used in a manner not specified by PCB Piezotronics, Inc. 

 

Caution 1 – ESD sensitivity 

Cables can kill your equipment.  High voltage electrostatic discharge (ESD) can damage electrical devices.  

Similar to a capacitor, a cable can hold a charge caused by triboelectric transfer, such as that which occurs in the 

following: 

 

 

Laying on and moving across a rug,  

 

Any movement through air,  

 

The action of rolling out a cable, and/or 

 

Contact with a non-grounded person.  

 

The PCB solution for product safety: 

 

 

Connect the cables only with the AC power off. 

 

Temporarily “short” the end of the cable before attaching it to any signal input or output.  

 

Caution 2 – ESD sensitivity 

 

ESD considerations should be made prior to performing any internal adjustments on the equipment.  Any 

piece of electronic equipment is vulnerable to ESD when opened for adjustments.  Internal adjustments should 

  

Содержание 682B03

Страница 1: ...itter Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail im...

Страница 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Страница 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Страница 4: ...Series 4 20mA Din Rail ICP Signal Conditioner Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800...

Страница 5: ...ORING Table of Contents Introduction Page 3 General Features Installation and Wiring Page 6 Configuring the 682BX3 Page 10 ESD Sensitivity Page 13 Ordering Information Page 14 Warranty Servicing Warra...

Страница 6: ...oner Optional 500Vdc Input to Output Electrical Isolation Selectable 24Vdc Unregulated 18Vdc regulated 4mA excitation to power sensor 4 20mA Output Signals for Vibration and Temperature Selectable 0 5...

Страница 7: ...stallation The 682 Series is designed to be mounted on a 35mm Din Rail Do not install in a harsh area where it can be exposed to cleaning fluids or machine oils IMI Sensors recommends mounting the 682...

Страница 8: ...closure in either the up or down direction terminate the wire in the correct location Do not exceed a torque of 0 5Nm Re install the terminal block This easy to assemble connection method allows devic...

Страница 9: ...7 to 8 Pin 7 Temperature Sensor Pin 8 Temperature Sensor ICP Accelerometer Raw Vibration RV Pins 9 to 10 and BNC Jack Pin 9 RV Pin 10 RV 4 to 20mA Temperature Output Pins 11 to 12 Pin 11 4 to 20mA Te...

Страница 10: ...D INSTRUMENTATION FOR MACHINE CONDITION MONITORING Typical Wiring Diagram To Maintain Conformance Earth Ground Power Supply Common and I O Shields must be connected together 682 Series Signal Conditio...

Страница 11: ...gnal conditioner for various sensor and vibration ranges The Filter Modules are installed to set the High and Low cutoff frequencies The Jumper selects unregulated regulated or no ICP power to the acc...

Страница 12: ...FF OFF ON ON OFF OFF OFF ON OFF ON OFF 2 0 in sec RMS OFF OFF ON ON OFF OFF ON OFF ON OFF OFF 2 0 in sec Peak OFF OFF ON ON OFF OFF OFF ON ON OFF OFF 10 mils p p OFF OFF OFF OFF ON ON OFF OFF OFF OFF...

Страница 13: ...PAGE 10 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Sensor Power Jumper Configuration 682 Series Signal Conditioner...

Страница 14: ...ESD sensitivity Cables can kill your equipment High voltage electrostatic discharge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer...

Страница 15: ...682A X 3 Frequency Response Isolation 0 3Hz to 10kHz Standard 1 3Hz to 1kHz 2 10Hz to 10kHz 3 10Hz to 1kHz 4 3Hz to 10kHz with 500Vdc I O Isolation 5 3Hz to 1kHz with 500Vdc I O Isolation 6 10Hz to 1...

Страница 16: ...ior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proce...

Страница 17: ...price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforese...

Страница 18: ...r maximum 100 mA 100 mA Settling Time 2 min 2 min Excitation Voltage delivered to sensor 17 to 19 VDC 17 to 19 VDC 1 2 Constant Current Excitation delivered to sensor 3 to 5 mA 3 to 5 mA 1 2 Output Sp...