background image

CODE

IDENT. NO.

52681

DWG. NO.

SCALE:

SHEET

DRAWN

CHECKED

ENGINEER

TITLE

UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:

DIMENSIONS IN MILLIMETERS

[ IN BRACKETS ]

XX

    

±

 

0.13

ANGLES

  

 

2 DEGREES

3425 WALDEN AVE. DEPEW, NY 14043

(716)  684-0001 E-MAIL:  [email protected]

DIMENSIONS  IN INCHES

DECIMALS     XX

  

 

±.01

ANGLES

  

 

2 DEGREES

FILLETS AND RADII 

 .003 - .005 

DECIMALS     X

   

 ±

 

0.3

FILLETS AND RADII 

0.07 - 0.13 

INSTALLATION DRAWING

60601

1 OF 2

1.5X

MODEL 3741 SERIES

DC ACCELEROMETER

XXX   ±.005

JDM

12/22/14

JDM

12/22/14

JJD

12/22/14

   

   

1

1

2

2

3

3

4

4

A

A

B

B

RECOMMENDED MOUNTING TORQUE ON CAP SCREW,6 IN-LBS [65 N-CM]

CG-CENTER OF SEISMIC MEASUREMENT, TOLERANCE 

.03 [

.8].

RECOMMENDED MOUNTING SURFACE SHOULD BE FLAT TO WITHIN .003 [.08] TIR 
OVER 

1.32 [33.34] WITH A                 FINISH FOR BEST RESULTS.

MOUNTING HOLE PREPARATION:

.089 [2.26] 

.22 [5.6] MIN

4-40 UNC-2B 

.15 [3.8] MIN

POWER
(RED)

POWER/SIGNAL
GROUND (BLACK)

 - OUTPUT (WHITE)

 + OUTPUT (YELLOW)

MODEL 081A103

MOUNTING SCREW
ASSEMBLY

(2 SUPPLIED)
 
FOR "M" OPTION
MODEL M081A103

MOUNTING SCREW
ASSEMBLY
(2 SUPPLIED)

POWER: (RED)
     CONNECT TO  DC VOLTAGE
     POWER SUPPLY. SEE

     SPECIFICATION SHEET FOR
     PROPER EXCITATION 
     VOLTAGE.
 

SHIELD:
     CASE GROUND

FOR METRIC OPTION
MOUNTING HOLE PREPARATION:

.098 [2.45] 

.39 [10.0] MIN

M3 X .5-6H 

.18 [4.6] MIN

LASER MARK: PCB LOGO, PCB MODEL #, UNIQUE SN. "XXX" IN MODEL NUMBER INDICATES FS 
RANGE (eg 3741B12200G). SEISMIC MASS LOCATIONS ARE NOT MARKED.

1

2

3

32 [.08]

3

2

2

1

1

2

4

5.)     SEE SHEET 2 OF 2 FOR CABLE STRAIN RELIEF INFORMATION.

60

60

1

PCB Piezotronics Inc. claims proprietary rights in

the information disclosed hereon.  Neither it nor any

reproduction thereof will be disclosed to others

without the written consent of PCB Piezotronics Inc.

.30 [7.7]

CABLE
TERMINATE TO PIGTAIL

.825 [20.96]

1.000 [25.40]

.590 [14.99]

.375 [9.53]

.425 [10.80]

.850 [21.59]

.125 [3.18]

2X  

THRU

4

.12 [3.0]

REVISIONS

REV

DESCRIPTION

DIN

NR

RELEASED TO DRAFTING

43667

Содержание 3741E12200G

Страница 1: ...lerometer Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 716 684 0001 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E...

Страница 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Страница 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...e applied acceleration The sensor element is electrically connected in a Wheatstone bridge circuit The integral amplifier provides a low impedance output to follow on instrumentation These particular...

Страница 7: ...ssembly With each conductor being 30 AWG Teflon coated The supplied cable length for a standard DC accelerometer is 10 ft or 120 in 3 m Custom cable length requirements should be specified at time of...

Страница 8: ...and stiff adhesives provide the best high frequency response METHOD 1 Adhesive Mounting Base This method involves attaching a base to the test structure then securing the sensor to the base This allow...

Страница 9: ...es to reduce the effects of EMI and RFI that is present near electrical motors and machinery Teflon jacketed cabling may be necessary to withstand corrosive environments and higher temperatures Feel f...

Страница 10: ...its provide the capability for continuous monitoring Note High sensitivity DC Accelerometers feature on board differential amplification 7 0 OPERATING NOTE Always operate the accelerometer within the...

Страница 11: ...s and costly errors Therefore in an effort to prevent the common mistakes associated with customer performed calibration this document includes a broad overview of the Back to Back Calibration techniq...

Страница 12: ...usly calibrated over the frequency and or amplitude range of interest 2 the shaker should be selected to provide minimal transverse lateral motion and minimal distortion and 3 the quality of the meter...

Страница 13: ...eturn policies and instructions When unexpected measurement problems arise call our 24 hour SensorLineSM to discuss your immediate dynamic instrumentation needs with a factory representative Dial 716...

Страница 14: ...r Integral Cable Integral Cable Electrical Connection Position Side Side Cable Termination Pigtail Ends Pigtail Ends Cable Type 010 4 cond Shielded 010 4 cond Shielded Cable Length 10 ft 10 ft Mountin...

Страница 15: ...MIN POWER RED POWER SIGNAL GROUND BLACK OUTPUT WHITE OUTPUT YELLOW MODEL 081A103 MOUNTING SCREW ASSEMBLY 2 SUPPLIED FOR M OPTION MODEL M081A103 MOUNTING SCREW ASSEMBLY 2 SUPPLIED POWER RED CONNECT TO...

Страница 16: ...rmation disclosed hereon Neither it nor any reproduction thereof will be disclosed to others without the written consent of PCB Piezotronics Inc REVISIONS REV DESCRIPTION DIN SEE SHEET 1 FASTEN CABLE...

Отзывы: