background image

Model Number

357A64

CHARGE OUTPUT ACCELEROMETER

Revision: A

ECN #: 48070

Performance

ENGLISH

SI

Sensitivity(± 10 %)

1.15 pC/g

.117 pC/(m/s²)

Measurement Range

± 1000 g pk

± 9800 m/s² pk

Frequency Range(± 10 %)

10 kHz

10 kHz

Resonant Frequency

45 kHz

45 kHz

[1]

Non-Linearity(per full scale range)

 1 %

 1 %

[3]

Transverse Sensitivity

 5 %

 5 %

Environmental

Overload Limit(Shock)

± 2000 g pk

± 19,600 m/s² pk

Temperature Range(Operating)

-67 to 1200 °F

-55 to 649 °C

Temperature Range

(Survivable Limit)

-67 to 1400 °F

-55 to 760 °C

Temperature Range

(Cable Termination)

-67 to 900 °F

-55 to 482 °C

Temperature Response

See Graph

See Graph

[1]

Radiation Exposure Limit(Integrated Neutron Flux)

1E10 N/cm²

1E10 N/cm²

Radiation Exposure Limit

(Integrated Gamma Flux)

1E8 rad

1E8 rad

Electrical

Capacitance

1000 pF

1000 pF

[1][2]

Insulation Resistance(@ 1200°F[649°C])

 30 kohm

 30 kohm

Insulation Resistance

(@ 70° F [21°C])

 1 GOhm

 1 GOhm

Electrical Isolation

Signal isolated from case

Signal isolated from case

Physical

Sensing Geometry

Shear

Shear

Housing Material

Nickel Alloy

Nickel Alloy

Sealing(Sensor Housing)

Hermetic

Hermetic

Sealing

(Connector)

Welded Hermetic

Welded Hermetic

Size (Height x Length x Width)

.47 in x .87 in x .51 in

11.9 mm x 22.1 mm x 13 mm

Weight(without cable)

.54 oz

15 gm

[1]

Electrical Connector

Integral Hardline Cable

Integral Hardline Cable

Cable Length

10 ft

3.05 m

Cable Type

MI Hardline Cable

MI Hardline Cable

Cable Termination

10-32 Coaxial Jack

10-32 Coaxial Jack

Mounting

Through Holes (2)

Through Holes (2)

Mounting Thread

6-32 Male

6-32 Male

[4]

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

OPTIONAL VERSIONS

Optional versions have identical specifications and accessories as listed for the standard model 

except where noted below. More than one option may be used.

NOTES:

[1] Typical.
[2] Additional cable length will add approx. 100pF/ft.
[3] Zero-based, least-squares, straight line method.
[4] See PCB Declaration of Conformance PS081 for details.

SUPPLIED ACCESSORIES: 

Model 64287-01 Mounting Stud 5-40 to 10-32 (1)
Model 68978-01 6-32 X 1/4" SHCS (2)
Model ACS-44 Extended amplitude response, upper 5% point to 10% point (requires ACS-1 or 
equivalent). (1)

Entered: LK

Engineer: JJD

Sales: MC

Approved: NJF

Spec Number:

Date: 3/29/2018

Date: 3/29/2018

Date: 3/29/2018

Date: 3/29/2018

67439 

3425 Walden Avenue, Depew, NY 14043

Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]

Содержание 357A64

Страница 1: ...rometer Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 716 684 0001 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E m...

Страница 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Страница 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...F 482 C and extreme application up to 100 F 650 C for UHT 12 These accelerometers are ideal for structural testing machine monitoring and vehicular shock and vibration measurement tasks where high tem...

Страница 7: ...urface consider adhesive mounting as a possible alternative Inspect the area checking that there are no burrs or other foreign particles interfering with the contact surface STEP 2 Wipe clean the moun...

Страница 8: ...or most applications It is generally used only for machinery monitoring and other portable trending applications Both the accuracy and repeatability at low 5 Hz and high frequency 1 kHz ranges are que...

Страница 9: ...o a precise sensitivity such as 10 0 or 100 0 mV g for ease of data analysis This is accomplished with most PCB laboratory charge amplifiers and some miniature in line units as well For fixed sensitiv...

Страница 10: ...dure themselves While this may result in both a savings of time and money it has also been attributed to incorrect readings and costly errors Therefore in an effort to prevent the common mistakes asso...

Страница 11: ...Figure 12 Typical Calibration Set Up Adhesively mounted sensors use similar practices However in this case a small portion of quick bonding gel or similar temporary adhesive is used to attach the tes...

Страница 12: ...s Incorrect Understand Back to Back Calibration limitations Do not expect the uncertainty of calibration to be any better than 2 In fact the uncertainty may be as high as 3 or 4 for frequencies 10 Hz...

Страница 13: ...Length x Width 47 in x 87 in x 51 in 11 9 mm x 22 1 mm x 13 mm Weight without cable 54 oz 15 gm 1 Electrical Connector Integral Hardline Cable Integral Hardline Cable Cable Length 10 ft 3 05 m Cable...

Страница 14: ...ROMETER DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 KRM 3 21 18 KRM 3 21 18 JJD 3 21 18 69015 PCB Piezotronics Inc claims proprietary rights in the information disclosed hereon Neither it nor any re...

Отзывы: