Performance
ENGLISH
SI
Sensitivity(± 50 %)(at 5 VDC excitation)
0.005 mV/g
0.0005 mV/(m/s²)
[1]
Sensitivity
0.001 mV/V/g
0.0001 mV/V/(m/s²)
[5]
Measurement Range
± 20 kg
± 196,133 m/s² pk
Frequency Range(± 1 dB)
0 to 10,000 Hz
0 to 10,000 Hz
[4]
Resonant Frequency
>60 kHz
>60 kHz
[4]
Damping Ratio
5 % Critical
5 % Critical
[4]
Non-Linearity(per 10,000 g (98,100 m/s²))
≤
1 %
≤
1 %
Transverse Sensitivity
≤
3 %
≤
3 %
Environmental
Overload Limit(Shock)
± 60,000 g pk
± 588,600 m/s² pk
[3]
Overload Limit
(Mechanical Stops)
≥
30 kg
≥
294,200 m/s² pk
Temperature Range(Storage)
-65 to 250 °F
-54 to 121 °C
Temperature Range
(Operating)
-65 to 150 °F
-54 to 65 °C
Temperature Coefficient of Sensitivity
-0.11 %/°F
-0.20 %/°C
[4]
Zero g Offset Temperature Shift
± 10 mV
± 10 mV
Base Strain Sensitivity
0.10 g/µ
ε
0.98 (m/s²)/µ
ε
[4]
Electrical
Excitation Voltage(Maximum)
12 VDC
12 VDC
Current Consumption
≤
10 mA
≤
10 mA
Input Resistance(± 700 Ohm)
2000 Ohm
2000 Ohm
[1]
Output Resistance(± 2000 Ohm)
6000 Ohm
6000 Ohm
[1]
Offset Voltage
-20 to +20 mVDC
-20 to +20 mVDC
[1]
Settling Time
0.01 sec
0.01 sec
[2]
Physical
Sensing Element
Piezoresistive MEMS
Piezoresistive MEMS
Sensing Geometry
Full Active
Full Active
Housing Material
Ceramic
Ceramic
Sealing
Hermetic
Hermetic
Size (Height x Length x Width)
0.15 in x 0.38 in x 0.28 in
3.8 mm x 9.6 mm x 7.1 mm
Weight
0.029 oz
0.82 gm
[4]
Electrical Connector
Solder Tabs
Solder Tabs
Mounting
Surface Mount
Surface Mount
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
NOTES:
[1] Verified with test data provided on supplied calibration certificate.
[2] Settling Time is the maximum time after power-up for the Offset Voltage to be /-2% of
Measurement Range output of the final offset value. Mounting surface must be at thermal
equilibrium.
[3] Half-sine pulse duration,
≥
20 µsec.
[4] Typical.
[5] Sensitivity is proportional to excitation voltage, and at other excitation values, sensitivity can
be predicted from the 5VDC calibrated value with a small (<~.5%) increase in uncertainty.
SUPPLIED ACCESSORIES:
Model ACS-62BT Shock Pulse Calibration of triaxial piezoresistive shock accelerometer to
maximum amplitude of 5k g, 5.0 VDC excitation
Entered: LK
Engineer: LAB
Sales: RWM
Approved: NJF
Spec Number:
Date: 3/20/2018
Date: 3/20/2018
Date: 3/20/2018
Date: 3/20/2018
62773
3425 Walden Avenue, Depew, NY 14043
Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]