Manual 21354 Rev E 
ECN 50523 

 

 

CAUTION 

Refers to hazards that could damage 
the instrument.  

 

 

 

NOTE  

Indicates tips, recommendations and 
important information. The notes 
simplify processes and contain 
additional information on particular 
operating steps.  

 

The following symbols may be found on the equipment 
described in this manual: 

 

 

This symbol on the unit indicates that 
high voltage may be present.  Use 
standard safety precautions to avoid 
personal contact with this voltage.

 

 

 

This symbol on the unit indicates that 
the user should refer to the operating 
instructions located in the manual. 

 

 

This symbol indicates safety, earth 
ground.

 

 

 
 
 
 
 
 
 
 

 
 
 

 

 

Содержание 261B03

Страница 1: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 2: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 3: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 4: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 5: ...3 6 0 Low Frequency Monitoring 3 7 0 Discharge Time Constant 4 8 0 Calibration 4 9 0 Troubleshooting 5 10 0 Maintenance 5 Figure Page 1 3 Component Force Link Axis Definition 2 2 ICP 3 Component Force...

Страница 6: ...sed upon the sensor ICP force link sensors contain built in microelectronic signal conditioning circuitry to provide clean low impedance output signals that can be transmitted over low cost cables and...

Страница 7: ...m 2 to 20 mA PCB standard battery powered signal conditioners are factory set at 2 mA and may be used to adequately drive a signal for 100 feet PCB line signal supplies are factory set at 4 mA and adj...

Страница 8: ...DTC represents the amount of time taken for the signal to decay to 37 of the initial peak value As illustrated in Figure 4 this is an exponential decay Approximately five DTC intervals are needed for...

Страница 9: ...sensor is of welded construction it should be returned to the factory for servicing in the event of serious malfunction Observe the following precautions in using the sensor Do not exceed the maximum...

Страница 10: ...ectral Noise 1 Hz Z 0 02 lb Hz 0 089 N Hz Spectral Noise 10 Hz Z 0 005 lb Hz 0 0222 N Hz Spectral Noise 100 Hz Z 0 002 lb Hz 0 0089 N Hz Spectral Noise 1 000 Hz Z 0 0005 lb Hz 0 00222 N Hz Output Pola...

Страница 11: ...ENGTH 5 2 0 5 LENGTH 100 6 0 100 LENGTH 1 0 2 54cm LENGTH 30 5cm 2 54cm 0 30 5cm LENGTH 1 5m 5 1cm 0 1 5m LENGTH 30 5m 15 2cm 0 30 5m LENGTH 30 5cm 0 A A Y X Z 74529 PCB Piezotronics Inc claims propri...