PCB Piezotronics 132 Series Скачать руководство пользователя страница 10

DETAIL  A

SCALE 10X

1

1

2

2

3

3

4

4

A

A

B

B

CODE

IDENT. NO.

52681

DWG. NO.

SCALE:

SHEET

DRAWN

CHECKED

ENGINEER

TITLE

UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:

DIMENSIONS IN MILLIMETERS

[ IN BRACKETS ]

ANGLES

  

 

2 DEGREES

3425 WALDEN AVE. DEPEW, NY 14043

(716)  684-0001 E-MAIL:  [email protected]

DIMENSIONS  IN INCHES

ANGLES

  

 

2 DEGREES

FILLETS AND RADII 

 .003 - .005 

FILLETS AND RADII 

0.07 - 0.13 

OUTLINE DRAWING

65444

1 OF 1

5X

ICP MICRO PRESSURE SENSOR

 

DECIMALS     XX   ±.03

XXX   ±.010

DECIMALS    X   ± 0.8

XX   ± 0.25

KRM

7/25/18

KRM

7/25/18

NJF

7/25/18

A

65

44

4

PCB Piezotronics Inc. claims proprietary rights in

the information disclosed hereon.  Neither it nor any

reproduction thereof will be disclosed to others
without the written consent of PCB Piezotronics Inc.

REVISIONS

REV

DESCRIPTION

DIN

C

REVISED TITLE, ADDED BLACK CONDUCTOR AND SILVER

CONDUCTOR CALLOUTS

48486

5.)  ALLOW RTV TO FULLY CURE

 
4.)  REMOVE EXCESS RTV FROM SENSOR AND MOUNTING HOLE SURFACES
 
3.)  INSERT SENSOR INTO BOTTOM OF MOUNTING HOLE, DATUM A

      SHOULD BE FLUSH WITH MOUNTING HOLE
 
2.)  LIGHTLY COAT THE INSIDE DIAMETER OF THE MOUNTING HOLE
      AND OUTSIDE DIAMETER OF SENSOR
 
1.)  PREPARE MOUNTING HOLE: 

.1285 [3.250] THRU

.30 [7.6]

.125

.002 3.18

.1

[

]

MODEL 132B38

MICRO SENSOR

A

(

.035 [0.89])

SENSING AREA

BLACK CONDUCTOR
GROUND

SILVER CONDUCTOR
SIGNAL/POWER

FEP TYPE CABLE

PCB MODEL NUMBER: 030
10 ft [3.1m] LONG

.042 [1.07]

Содержание 132 Series

Страница 1: ...sor Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 716 684 0001 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...rs is not attenuated nor is noise appreciably increased by the cable 2 0 DESCRIPTION 132 Series Microsensors feature small diameter pressure sensing surfaces incorporating very small 1 mm piezoelectri...

Страница 7: ...n of indicator panel the IC amplifier is providing proper bias normally 11 VDC cable connections are normal and the system is ready to operate If the needle moves to the red area of the fault monitor...

Страница 8: ...ook flat topped on the readout after about 10 volts The initial rise of the output will be accurate up to the point of clipping This can allow for an accurate time of arrival measurement even though t...

Страница 9: ...ainless Steel Sealing Epoxy Epoxy Weight 0 45 oz 12 77 gm 5 Cable Termination Pigtail Pigtail Cable Type 030 Coaxial 030 Coaxial All specifications are at room temperature unless otherwise specified I...

Страница 10: ...rights in the information disclosed hereon Neither it nor any reproduction thereof will be disclosed to others without the written consent of PCB Piezotronics Inc REVISIONS REV DESCRIPTION DIN C REVIS...

Отзывы: