Model Number

 

103B02

 

ACOUSTIC ICP PRESSURE SENSOR

 

Revision: B 

ECN #: 40794

 

 

Performance 

ENGLISH 

SI 

Measurement Range

 

3.00 psi

 

180.3 dB

 

 

Useful Overrange

 

6.00 psi

 

186.3 dB

 

[1]

 

Sensitivity(± 15 %)

 

1500 mV/psi

 

217.5 mV/kPa

 

 

Maximum Pressure

 

250 psi

 

1724 kPa

 

 

Resolution

 

0.02 mpsi

 

77 dB

 

 

Resonant Frequency

 

 13 kHz

 

 13 kHz

 

 

Rise Time

 

 25 µ sec

 

 25 µ sec

 

 

Low Frequency Response(-5 %)

 

5 Hz

 

5 Hz

 

 

Non-Linearity

 

 2.0 % FS

 

 2.0 % FS

 

[2]

 

Environmental 

Acceleration Sensitivity

 

 0.0005 psi/g

 

 0.0035 kPa/(m/s²)

 

 

Temperature Range(Operating)

 

-100 to 250 °F

 

-73 to 121 °C

 

 

Temperature Coefficient of Sensitivity

 

 0.2 %/°F

 

 0.36 %/°C

 

 

Maximum Flash Temperature

 

1000 °F

 

538 °C

 

 

Maximum Shock

 

1000 g pk

 

9807 m/s² pk

 

 

Electrical 

Discharge Time Constant(at room temp)

 

 0.1 sec

 

 0.1 sec

 

 

Excitation Voltage

 

20 to 30 VDC

 

20 to 30 VDC

 

 

Constant Current Excitation

 

2 to 20 mA

 

2 to 20 mA

 

 

Output Impedance

 

 100 Ohm

 

 100 Ohm

 

 

Output Bias Voltage

 

7 to 13 VDC

 

7 to 13 VDC

 

 

Physical 

Sensing Element

 

Ceramic

 

Ceramic

 

 

Housing Material

 

Stainless Steel

 

Stainless Steel

 

 

Diaphragm

 

316L Stainless Steel

 

316L Stainless Steel

 

 

Sealing

 

Welded Hermetic

 

Welded Hermetic

 

 

Electrical Connector

 

10-32 Coaxial Jack

 

10-32 Coaxial Jack

 

 

Weight

 

0.11 oz

 

3.15 gm

 

 

All specifications are at room temperature unless otherwise specified. 
In the interest of constant product improvement, we reserve the right to change specifications without notice. 

ICP

®

 is a registered trademark of PCB Group, Inc. 

 

OPTIONAL VERSIONS 

Optional versions have identical specifications and accessories as listed for the standard model 

except where noted below. More than one option may be used.

 

 

 
M 

- Metric Mount

 

Supplied Accessory : Model 060A24 Clamp nut M14 x 1.25-6G thd 11 mm hex 17-4 SS material 
(1) 

 

NOTES:

[1] For +10 volt output, minimum 24 VDC supply voltage required. Negative 10 volt output may 

be limited by output bias.

[2] Zero-based, least-squares, straight line method.

 

 

 

SUPPLIED ACCESSORIES:  

Model 060A10 Clamp nut 1/2-20-2A thd 7/16" hex (1) 
Model 065A66 Adhesive Mounting Ring (3) 
Model 160-0242-00 O-ring .250x.375(2-0100) (3) 

Entered: AP

 

Engineer: jg

 

Sales: KWW

 

Approved: BAM

 

Spec Number:

 

Date: 3/18/2013

 

Date: 3/18/2013

 

Date: 3/18/2013

 

Date: 3/18/2013

 

24258 

 

3425 Walden Avenue, Depew, NY 14043

Phone: 716-684-0001 
Fax: 716-684-0987 
E-Mail: [email protected]

Содержание 103B02

Страница 1: ...URE SENSOR Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E ma...

Страница 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Страница 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Страница 4: ...igh sensitivity Models 103A02 and 103A12 ICP Sound Pressure Sensors 2 0 DESCRIPTION Refer to installation drawing no 103 1010 90 included as part of this manual The 103A Series Sensors utilize a bimor...

Страница 5: ...2 since the radial wire leads of the Model 103A and 103A11 would interfere with the clamp nut The installation drawing gives detailed instructions on preparation of the port for this type of installat...

Страница 6: ...pled signal conditioner such as the Model 484B Consult factory for details 5 0 CALIBRATION The 103A Series Sensors must be dynamically calibrated using a known step function or pulse or with a microph...

Страница 7: ...s Steel 316L Stainless Steel Sealing Welded Hermetic Welded Hermetic Electrical Connector 10 32 Coaxial Jack 10 32 Coaxial Jack Weight 0 11 oz 3 15 gm All specifications are at room temperature unless...

Страница 8: ......

Страница 9: ......

Страница 10: ......

Отзывы: