PBI DMM-1701IM Скачать руководство пользователя страница 3

                                                                                                        1701IM 

 

- 1 - 

Notices 

 

COPYRIGHT 

(Copyright © 2012 Beijing Jaeger Communication Electronic Technology Co., Ltd.) 

Not to  be copied, used or  translated  in part or  whole  without  Beijing Jaeger  prior consent in  writing 
except approval of ownership of copyright and copyright law. 

WARRANTY 

This  warranty  does  not  cover  parts  which  may  become  defective  due  to  misuse  of  the  information 
contained in this manual. 
Read this manual carefully and make sure you understand the instructions provided. For your safety, 
be aware of the following precautions. 

WARNING! IMPORTATNT SAFETY INSTRUCTIONS

 

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE 
COVER  (OR  BACK).  NO  USER  SERVICEABLE  PARTS  INSIDE.  REFER 
SERVICING TO QUALIFIED SERVICE PERSONNEL.   

WARNING 

• To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 
• To avoid explosion danger, do not dispose of batteries in an open fire. 

C

M

A

RK 

FO

E

UR

O

P

EA

N H

A

RM

O

NIS

E

D ST

A

ND

A

RDS

 

The  CE  mark  which  is  attached  to  these  products  means  it  conforms  to  EMC 
Directive (89/336/EEC) and Low Voltage Directive (73/23/EEC). 

 

 

IMPORTANT INFORMATION 

Please retain the original packaging, should it be necessary at some stage to return the unit. 

Disposal  of  Old  Electrical  and  Electronic  Equipment  (Applicable  in  the  European  Union  and 
other European countries with separate collection systems)

 

This symbol on the product or on its packaging indicates that this product shall not 
be treated as household  waste. Instead it shall be handed  over to the  applicable 
collection  point  for  the  recycling  of  electrical  and  electronic  equipment.  By 
ensuring  this  product  is  disposed  of  correctly,  you  will  help  prevent  potential 
negative  consequences  for  the  environment  and  human  health,  which  could 
otherwise  be  caused  by  inappropriate  waste  handling  of  this  product.  The 
recycling  of  materials  will  help  to  conserve  natural  resources.  For  more  detailed 
information about recycling of this product, please contact your local Civic Office, 
your  household  waste  disposal  service,  or  the  shop  where  you  purchased  the 
product. 

COPYRIGHTS 

Television  programs,  movies,  video  tapes,  discs,  and  other  materials  may  be  copyrighted. 
Unauthorized  recording  of  copyrighted  material  may  be  against  the  copyright  laws  in  your  region. 
Also, use of this product with cable television transmissions may require authorization from the cable 
television operator or transmitter/owner. 

VENTILATION 

•  Do not expose the product to high temperatures, such as placing it on top of other product that 

produce heat or in places exposed to direct sunlight or spot lights. 

•  The ventilation slots on top of the product must be left uncovered to allow proper airflow into the 

unit.   

•  Do not stand the product on soft furnishings or carpets.     
•  Do not stack electronic equipment on top of the product.   
•  Do  not  place  the  product  in  a  location  subject  to  extreme  changes  in  temperature.  The 

temperature gradient should be less than 10 degrees C/hour. 

•  Place the product in a location with adequate ventilation to prevent the build-up of heat inside the 

product.  The  minimum  ventilation  space  around  the  unit  should  be  7  cm.  The  ventilation  should 
not be impeded by covering the ventilation openings with items, such as newspapers, table cloth, 
curtains, etc. 

Содержание DMM-1701IM

Страница 1: ...Twin IP to Analog Trans modulator User Manual http www pbi china com ...

Страница 2: ...ear panel instructions 6 5 1 Front panel 6 5 2 Rear panel 7 6 Menu Operating Instructions Via DMM 1000CU 8 6 1 Status 9 6 2 Config 9 6 3 Network 11 6 4 System 11 7 Web Control 12 7 1 Status Page 12 7 2 Input Setting Page 13 7 3 RF Page 14 7 4 Decoder 1 2 Page 15 7 5 System Page 17 8 Installation 20 9 Accessories 20 ...

Страница 3: ...oint for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of t...

Страница 4: ...onnected from the AC power source mains as long as it is connected to the power outlet or wall socket even if the product is turned off If the product will not be used for a long period of time disconnect it from the AC power outlet or wall socket ...

Страница 5: ... device it is essential that both operating and servicing personnel follow generally accepted safety procedures in addition to the safety precautions specified in this manual Whenever it is likely that safety protection is impaired the device must be made in operative and secured against unintended operation The appropriate servicing authority must be informed For example safety is likely to be im...

Страница 6: ...t input ports Support A2 stereo modulation optional Two adjacent analog channels output in range of 48 860MHz Out level 100dBuV per channel Remote control and supervision by SNMP and HTTP web Upgrade via FTP or USB Accommodated in 4RU 19 chassis DMM 1000MF which supports up to 8 modules and equipped with auto backup Power Supply module 3 Technical Specifications IP Input Connector Type 2 RJ45 10 1...

Страница 7: ...Carrier Frequency main 6 5MHz 5KHz D K 6 0MHz 5K I 5 5MHz 5KHz B G 4 5MHz 5KHz M N Audio Carrier Frequency second Only suitable to A2 Stereo trans modulator 6 742MHz 5KHz D K 6 258MHz 5KHz D K Poland 5 742MHz 5KHz B G 64 742MHz 5KHz M N Control Monitoring Connector Type 1 RJ45 10 100 Base T for Web Control Remote Control SNMP HTTP WEB interface Local Control Handheld Programmer Unit Software Upgra...

Страница 8: ...nformation DMM 1701IM xx series IP Input type Model Video Audio MONO A2 PAL D K 02 04 PAL D K Poland 08 PAL B G 12 14 NTSC 22 SECAM D K 32 34 SECAM L 42 PAL I 52 5 Front panel and rear panel instructions 5 1 Front panel ...

Страница 9: ...of this device A4 Reset Used to reset the device s settings A5 Power Power indicator green light means power supply is working well A6 Alarm Alarm indicator green light means this device is working well A9 Handset Used to connect DMM 1000CU handset unit for control 5 2 Rear panel B1 RF Out primary RF output port B2 RF Monitor 20dB output port for monitoring ...

Страница 10: ...F Audio Mode 1 RF Audio Mode 2 RF Switch 2 RF Modulator Mode USB Status Service Service Type Service Name Provider Name Video Video PID Audio Audio PID Local Setting IP Address Network Mask Gateway Tarp IP Tarp IP Address HTTP Login Username Password Version Info Product Name 1701IM Factory Setting Debug Mode Setting Force Upgrade Config Program Video Output Video Standard Aspect Ratio Subtitle pr...

Страница 11: ... of modulated program2 6 RF Swich 2 Display if the RF function for program2 is enabled or disabled 7 RF Modulation Mode Display the analog format of programs outputted from RF 6 1 3 Decoder 1 2 1 Service Display some information of decoded program such as Service Type Service Name Provider Name 2 Video Display the video PID of decoded program 3 Audio Display the audio PID of decoded program 6 1 4 ...

Страница 12: ... language of subtitle Close Caption Enable or Disable the function of closed caption by selecting OFF or ON CVBS Sub Select the CVBS sub standard among PALBDGHZ PALN ALN C and SECAM 3 Audio Output Configure parameters of audio output It has 3 options as below Audio Level Configure the audio level its range is 0 99 Audio Mode Select the audio mode among Stereo Mono Dual Left and Right Audio Priorit...

Страница 13: ...al Setting 1 IP Address Configure the local IP address 2 Network Mask Configure the local network mask for local IP address 6 3 2 Trap IP Configure the trap address for a PC to receive warning information 6 3 3 HTTP Login 1 Username Configure the username for user to login on web control The default value is root 2 LoginPasswd Configure the password for user to login on web control The default val...

Страница 14: ...er name and password are root and 12345 If you forget these you can use DMM 1000CU to check and change 7 1 Status page Here user can check status of TS IP input as it shown in figure below 1 IP status Check the input bit rate of these 2 TS IP input ports 2 RF status Check the modulation status of these 2 built in modulators 3 Decoder 1 Status Check the status of programs from TS IP input port1 thi...

Страница 15: ...arameters of local IP board1 including IP address subnet Mask and gateway 2 Stream IP 2 Setting Configure parameters of local IP board2 including IP address subnet Mask and gateway 3 Uni Multicast 1 Settings Configure parameters of TS IP input port1 including IP address port number and protocol UDP RTP 4 Uni Multicast 2 Settings Configure parameters of TS IP input port2 including IP address port n...

Страница 16: ...r1 2 RF Frequency 2 KHz This parameter has to be 8MHz larger than Frequency 1 so it can t be assigned at user s will 3 RF Level dBuV Configure the level for RF out 4 RF Audio Mode 1 Configure the audio mode for built in modulator1 user can select among Stereo Mono and Dual 5 RF Audio Mode 2 Configure the audio mode for built in modulator1 user can select among Stereo Mono and Dual 6 RF Switch 2 Se...

Страница 17: ...r modulation Click the button Apply or Cancel to submit or undo your new configuration as it shown in figure below 1 Audio Level Configure the audio volume 2 Audio Mode Select between Stereo Mono Dual Left and Right 3 Audio Priority Configure the language of outputted audio 7 4 2 Video User can check and configure video parameters for modulation Click the button ...

Страница 18: ...st 4 Subtitle Language Select the language of video subtitle 5 Closed Caption Enable or disable the closed caption by selecting ON or OFF 6 CVBS SUB Select among PALBDGHI PALN PALN_C and SECAM 7 4 3 Decoder Play User can check and choose the program for modulation including audio level Click the button Apply or Cancel to submit or undo your new configuration as it shown in figure below 1 Current P...

Страница 19: ... Mode User can choose among BISS 0 BISS 1 and BISS E 2 Key Configure the key for BISS descrambling 3 ID Configure the ID for BISS E descrambling 7 5 System page Here user can configure and check system parameters of this device 7 5 1 Device User can check information of this device Click the button Apply or Cancel to submit or undo your new configuration as it shown in figure below ...

Страница 20: ...he web page 3 HTTP Login Configure the username and password for user to login on web control 4 Factory Default Used to restore all parameters to factory default value 5 Device Reboot Used to restart this device 7 5 2 Version User can check version information of this device including Main Version Web Version Kernel Version and Decoder Version as it shown in figure below ...

Страница 21: ...ss Subnet mask and Gateway 2 Trap IP Address Configure the IP address for malfunction warning It will automatically send the warning information to the PC which IP address is this trap IP address 7 5 4 Upgrade User can upgrade the softer version of this device Click the button to choose the upgrade document stored in your PC and Click the button Upgrade to execute the upgrade process User had bett...

Страница 22: ...f inspection and configuration The POWER Indicator LED will always light on during working If not use the device please pull out the AC plug If user wants to reboot device please leave it for at least 5 seconds after shutting it down Take this device out of the DMM 1000MF if user doesn t use it for a while 9 Accessories Front panel 1PC Rear panel 1PC CD ROM 1PC Certificate of quality Guarantee car...

Отзывы: