background image

User Maintenance

WARNING

A. General Housekeeping (Continuous).

1. Keep boiler area clear and free of combustible materials and obstructions to the free flow of

combustion and ventilation air to the boiler.

2. Do not store or use gasoline or other flammable vapors or liquids in the vicinity of the boiler or any

other appliance.

3. Do not store or use sources of hydrocarbons in the vicinity of the boiler. Sources of hydrocarbons

include bleaches, cleaners, chemicals, sprays, paint removers, fabric softeners and refrigerants.

4. Check safety relief valve for water leakage. If leakage exists, contact a qualified service agency.

B. Inspect Vent System (Monthly).

1. Vent pipe must be continuous to chimney with no separations, obstructions, or sags. Vent pipe

must be supported at minimum 4 foot (1.2 m) intervals and secured with sheet metal screws.

2. Chimney must not have signs of continuous wetness. If signs of continuous wetness are observed,

contact a qualified service agency.

C. Inspect Pilot and Main Burner Flames (Monthly).

1. Remove front jacket panel by lifting and pulling out.

2. Adjust thermostat to highest setting. Verify operation follows Sequence of Operation (see page 3.)

3. View flames through observation port. See Figure 1.

4. Check pilot flame. See Figures 5 and 6. The pilot flame should be medium blue covering

approximately 3/8" to 1/2" (10 mm to 13 mm) of the thermocouple or flame sensor. If the flame is
yellow and lazy, follow instructions TO TURN OFF GAS TO APPLIANCE (see Figures 2 - 4), and
contact a qualified service agency.

5. Check main burner flames. See Figures 5 and 6. The flames should have clearly defined inner

cones approximately 1-1/2" (40 mm) high and should have a very sharp blue color characteristic. If
the flame is yellow and lazy, follow instructions TO TURN OFF GAS TO APPLIANCE (see Figures
2 - 4), and contact a qualified service agency.

6. Adjust thermostats to normal setting.

7. Install front jacket panel.

8

Service on this boiler should be undertaken only by trained and skilled personnel from a
qualified service agency. Inspections should be performed at intervals specified in the
Installation, Operation and Maintenance Manual and this User’s Information Manual. Maintain
manuals in a legible condition.

Keep boiler area clear and free of combustible materials, gasoline and other flammable vapors
and liquids.

Do not place any obstructions in boiler room that will hinder flow of combustion and
ventilation air.

Содержание Series GM

Страница 1: ...ty damage personal injury or loss of life W WA AR RN NI IN NG G Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMEL...

Страница 2: ...are present in the combustion area The control is a single use device If the control is activated to interrupt boiler operation do not attempt to place boiler in operation Contact a qualified service...

Страница 3: ...calls for heat 2 Limit senses boiler water temperature Prevents operation until water temperature falls approximately 15 F 8 C below the cut out temperature 3 Automatic vent damper if used opens 4 Ga...

Страница 4: ...rs Note If pilot flame is not detected main and pilot gas are automatically turned off Refer to Paragraph B above to resume operation c Spark Ignited Pilot Pilot flame detected 1 Main gas on igniting...

Страница 5: ...Figure 2 Operating Instructions SmartValve Intermittent Ignition boiler model suffix SV 5...

Страница 6: ...Figure 3 Operating Instructions Spark Ignition boiler model suffix SPRK 6...

Страница 7: ...Figure 4 Lighting Instructions Standing Pilot boiler model suffix STDG 7...

Страница 8: ...ify operation follows Sequence of Operation see page 3 3 View flames through observation port See Figure 1 4 Check pilot flame See Figures 5 and 6 The pilot flame should be medium blue covering approx...

Страница 9: ...l For continued safe operation a qualified service agency must provide a more detailed inspection of burners heat exchanger and vent system and provide maintenance as specified in the Installation Ope...

Страница 10: ...entilation Wear a NIOSH MSHA approved respirator Wear long sleeved loose fitting clothing and gloves to prevent skin contact Wear eye goggles Minimize airborne dust prior to handling and removal by wa...

Отзывы: