NOTES FOR FIGURES 27 -- 34
1. Heat pump MUST have a high pressure switch for dual fuel applications.
2. Refer to outdoor equipment Installation Instructions for additional information and setup procedure.
3. If the heat pump date code is 1501E or earlier, select the “ZONE” position on the two--speed heat pump control. Heat pumps having
date codes 1601E and later do not have or require a “ZONE” selection.
4. Outdoor Air Temperature Sensor must be attached in all dual fuel applications.
5. Does not apply for this model.
6. Does not apply for this model.
7. Does not apply for this model.
8. Does not apply for this model.
9. Does not apply for this model.
10. Does not apply for this model.
11. Optional connection: If wire is connected, dip switch SW1--2 on furnace control should be set in ON position to allow thermostat to
control furnace staging.
12. Optional connection: If wire is connected, ACRDJ jumper on furnace control should be removed to allow thermostat to control out-
door unit staging.
13. Furnace must control its own high--stage heating operation via furnace control algorithm.
14. The RVS Sensing terminal “L” should not be connected. This is internally used to sense defrost operation.
15. DO NOT SELECT the “FURNACE INTERFACE” or “BALANCE POINT” option on the two--speed heat pump control board. This
is controlled internally by the Dual Fuel Thermostat.
16. Dip switch D on Dual Fuel Thermostat should be set in OFF position for single--speed compressor operation. This is factory default.
17. Dip switch D on Dual Fuel Thermostat should be set in ON position for two--speed compressor operation.