background image

PAGE 7

PaxLock reset

The PaxLock holds address information for the bridge that it is bound to. This will cause 

problems if the unit is to be used on another system.

The unit requires a hardware reset to clear its bridge information.  This is achieved as follows:

1. Remove the inside handle from the door by loosening the securing grub screw.

2. Remove the cover by holding the bottom edge and pulling it towards you. The cover will lift

    off at the top when the bottom edge is clear of the housing.

3. Locate the red reset button at the top of the unit.

4. Hold the button down and wake up the unit by pressing the front push button.

    The unit will give a beep when the reset has started. You can now release the reset button.

5. The Red and Green LED's will both flash until the process has finished.

6. Refit the cover and handle.

7. You can now enrol the unit.

10,000

250

64

10

100

65 ft

3,584

1 inch

1

/

4

 inch

4 x AA

0 °C (-32 °F)

+55 °C (+131 °F)

IPX4

6V DC

1

/

2

 inch

13 inch

3

/

8

 inch

1

/

4

 inch

13 inch

4 inch

Operating temperature - Battery limits

Environment 

Dimensions

Features

External use

Min

Width

Height

Max

Depth

Min

Max

Access Levels

Time Zones

Door open time

ACU's per Net2Air bridge - Recommended

Events stored in ACU with no server connection

Number of Cards

Specifications

Yes

Net2Air bridge (data lines) per system
Net2Air wireless range to ACU

The declaration of conformity is available on request. Contact details are provided at:   

http://paxton.info/596

Low

Reader/Keypad module (Required space on Door)

Total outside dimensions (includes handle clearance) 

Battery Type
Typical Battery Life

Vandal resistance

Read Range

Keyfob

Token

This product is not suitable for retail sale.  All warranties are invalid if this product is not installed by a trained technician.

Use site surveyor

Voltage

2 years or 30,000 ops 3 years or 60,000 ops Max = Low power mode

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

 (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate the equipment. 

FCC Compliance

1 sec

60 secs

Содержание Net2 PaxLock

Страница 1: ... com Net2Air Site Surveyor 690 200 US This access control unit uses wireless communication It is recommended that a Net2Air site surveyor is used to determine the best position for the bridge and control units This wireless unit requires a Net2Air bridge to communicate with the server PC Paxton 1 2 3 4 5 6 7 8 9 AA AA 1 Front Lock Assembly 2 Rear Lock Assembly 3 Door Handle x 2 4 Mounting screw 1 ...

Страница 2: ...of damaging the door face when the drill breaks through Step 3 Contact switch optional If a contact switch is to be fitted an additional hole is required in the edge of the door Drill a hole of the required size to receive the switch assembly This should intersect the 5 8 hole drilled previously to take the wiring harness Feed the door contact wires through the door to exit on the inside Ø 16 37 1...

Страница 3: ... into the socket in the rear lock assembly Locate the top of the cover over the housing and push flush to the door Clip in the 4 x AA batteries with reference to the label displayed below the holder assembly Step 8 Fitting the batteries Where a contact swich is fitted connect the wires to the terminal block provided on the pcb Step 7 Wiring contact switch option Mounting screws are provided in thr...

Страница 4: ...r and waits for a response from Net2 If more than one bridge replies the unit checks the signal strength and selects the strongest bridge to communicate with The Net2 software confirms that the token number is in the database and registers the PaxLock bridge binding The LED s will go out when the process has finished The software must be in commissioning mode which is the default setting If this h...

Страница 5: ... handle is engaged An invalid user card has been presented No access granted LED indications Green flash The unit is configuring Please wait The access control unit connects to the Net2 software running on the PC using Paxton Net2Air proprietary wireless technology A Net2Air bridge enables communication from the Net2 software to the Paxton wireless products Radio signals do not always behave as yo...

Страница 6: ... to the Net2 PC which responds with any updates This keeps the PaxLock updated even when there is no activity at the door and maximises battery life Sleep mode As the battery voltage falls the unit will update the Net2 server with its battery condition This voltage level is displayed as a colored battery icon alongside the door in the Doors screen When the batteries approach the end of their life ...

Страница 7: ...Dimensions Features External use Min Width Height Max Depth Min Max Access Levels Time Zones Door open time ACU s per Net2Air bridge Recommended Events stored in ACU with no server connection Number of Cards Specifications Yes Net2Air bridge data lines per system Net2Air wireless range to ACU The declaration of conformity is available on request Contact details are provided at http paxton info 596...

Отзывы: