Here is the list of topics about this product that receive the most technical support enquiries.

We list them here to help you speed up the installation and trouble shooting process.

1 - Re-enrolling barred tokens.

Q

Tokens that have been barred by presenting their corresponding shadow card can 

be re-enrolled by presenting the Enrolment card to the reader followed by the barred token. 

2 - Enrolling a function card pack.

Q

 You will need an existing valid enrolment card for this system. Present 

this enrolment card to the reader and the Amber LED will flash and the Green & Red LED's will be off. Present the 

enrolment card from the function card pack. The reader will then beep and all the LED's will come on. The function 

cards will now be valid. Repeat this with each controller. 

3 - Adding an additional card pack.

Q

 You need to be in possession of the original enrolment card. Present the 

original enrolment card to the reader and the Amber LED will flash, Green & Red LED's will be off, then present the 

Enrolment card from the new card pack; the reader will beep and all LED's will be lit. The additional cards will now be 

valid. Repeat this with each reader and with any additional card packs. Any valid enrolment card can be used to add 

further packs. This is the same for enrolling function card packs onto a system.

4 - Can I put a relay across the lock wire output?

Q

 Yes - All  PROXIMITY P series compact readers have been 

designed to drive relays.

5 - Integration with an entry phone system.

Q

 The output from the entry phone system is used to simulate an 

exit button on the Paxton equipment. No voltage should be applied to the exit input wires (Blue / Mauve) of a compact 

unit.  Most phone systems will provide a voltage pair to release the door lock; this voltage must be used to drive an 

independent relay. The relay contacts must be 'normally open going closed'  to mimic a 'push to make' exit button.  

Only if the output pair from the phone system is voltage free can this be connected directly to the exit input wires.

6 - Paxton Exit buttons.

Q

   Red wire - Power supply 12V DC.   Green wire - Power supply 0V.  Grey wire - Mauve 

compact wire.  Black wire - Blue compact wire.   The LED will be constantly lit and will not flash. 

7 - Bar/Disable All Users card on a system with several card packs.

Q

 Once additional card packs are enrolled 

onto a system, any function card from the packs will effect all cards packs. So, using any Bar/Disable All Users card 

will bar all users from the system.

8 - Connecting a compact with another control unit.

Q

 This cannot be done. Paxton Compact systems have the 

control electronics built in and no direct data output is provided.  The Switch2 and Net2 system use a different type of 

data input.  Note: The compact system will control the door unit on its own.

9 - Read in and read out on one door.

Q

 You cannot wire two compact systems in parallel to a common lock as this 

may result in damage to your system. They will both power the door lock independently and will not offer single point 

control.  We recommend using one Switch2 controller with two compatible keypads or readers.

10 - Re-enrol a user - Multiple enrolment cards.

Q

 If multiple card packs are enrolled there will be multiple 

enrolment cards. Any enrolment card that is assigned to the system can be used to re-enrol a barred user. Present one 

of the enrolment cards followed by the user card to re-enrol a barred user.

Technical Help

Содержание Ins-30003 PROXIMITY P Series

Страница 1: ...Ins 30003 PROXIMITY P series compact reader ...

Страница 2: ...xton co uk support paxton co uk 01273 811011 Quickstart guide This supplement is a brief guide to installing a P series compact system Further information is available for download at http www paxton co uk or call the communications team on 01273 811011 Exit button push to make Electric release 12V DC power supply 12V DC release current rating must be less than 1A 0V 0V 0V 12V 12V Exit ...

Страница 3: ...he reset OR 1 Present Enrolment card 2 Present Door open time card twice 3 Present Enrolment card 4 Present Door open time card twice 5 WAIT FOR 5 SECONDS Wiring The unit should be mounted in conjunction with an electrical backbox to achieve the required clearance for the connector If an adaptor plate 310 750 is fitted the mountings on the backbox can also be used The reader s default indication h...

Страница 4: ...ader User cards Shadow cards BEEP BEEP 2 3 4 1 At ins tal lat ion pr es en t th is ca rd to th e re ad er to va lid ate th e to ke ns in th is pa ck 2 To re v ali da te a us er to ke n pr es en t th is en ro lm en t ca rd to th e re ad er fol low ed by th e us er to ke n Pa xto n Ac ce ss FUNCTION CARD enro lm ent card Mo re inf o ht tp pa xto n inf o 74 1 At ins tal lat ion pr es en t th is ca rd...

Страница 5: ... The reader will start beeping 3 Wait for the required period you wish the door to remain open 4 Present the card again at the end of the period to set the open time The beeping will stop 1 2 3 4 BEEP BEEP Pa xto n Ac ces s FUNCTIO N CARD door open tim e ca rd Th e pe rio d tha t the do or is un loc ke d for wh en a va lid tok en is pre sen ted is set as fol low s 1 Pre sen t thi s car d 2 Wa it f...

Страница 6: ...ack white grey blue and silver Registered installers can order these free of charge by logging onto the secure installer extranet http paxton info 1035 or if you are not a registered installer please call us on 01273 811011 for more information Fitting ...

Страница 7: ...age should be applied to the exit input wires Blue Mauve of a compact unit Most phone systems will provide a voltage pair to release the door lock this voltage must be used to drive an independent relay The relay contacts must be normally open going closed to mimic a push to make exit button Only if the output pair from the phone system is voltage free can this be connected directly to the exit in...

Страница 8: ...lf tapping screw zinc 3 Wall Plugs 1 Pozi pan self tapping screw small 5 Cable clips Switchable current Features Door open time Time zones with additional time clock Silent operation Can be used with fail OPEN locks Can be used with fail CLOSED locks Exit button input Door Contact input Number of Users Cable length Min Max Voltage Specifications Operating temperatures all items Electrical Environm...