Paxton Ins-30003 PROXIMITY P Series Скачать руководство пользователя страница 5

Fail open release card - Compact systems are fail closed as default

3

BEEP! 

BEEP! 

 

 

 

This ca

rd is 

used with 

systems 

where a

 fail open

electric release is 

used f

or the saf

e opera

tion in the 

event of

 a fire.  Present 

the 

ca

rd 

to 

the reader 

to

drive a 

fail 

open 

release

 or a maglock.  

Present th

ca

rd 

again 

to revert 

to the f

ail closed opera

tion

Paxton A

ccess

FUNCTION 

CARD

fail 

open release

This ca

rd is 

used with systems where a

 fail open

electric release is u

sed for the saf

e opera

tion in 

the 

event 

of 

a fire.  Prese

nt 

the 

card to the 

rea

der to

drive a

 fail open release 

or 

a maglock.  Present 

the 

ca

rd again to revert 

to 

the 

fail closed 

operation

Paxton 

Access

FUNCTION 

CARD

fail 

open release

This card is used with systems where a fail open

electric release is used for the safe operation in the 

event of a fire.  Present the card to the reader to

drive a fail open release or a maglock.  Present the 

card again to revert to the fail closed operation

FUNCTION CARD

fail open release

THIS CARD CAN ONLY BE USED WITH A FAIL OPEN LOCK.

1. Take the fail open release function card from the starter pack.

2. Present/swipe the card through the reader. The reader will beep for about a second.

3. The reader is now set to fail open mode. This allows safe operation of the door in case of fire: The lock will

     release when the power is cut.

4. To revert to fail closed mode, swipe the card again and the reader will beep once.

Door open time (seconds) 

1. Take the 'door open time' card from the starter pack.

2. Present the card to the reader. The reader will start beeping.

3. Wait for the required period you wish the door to remain open.

4. Present the card again at the end of the period to set the open time. The beeping will stop.

BEEP! 

BEEP! 

Paxton 

Access

FUNCTION CARD

door 

open time card

The 

period that 

the 

door 

is unlocked for when a

 

va

lid token is presente

d is set as follows:

1.  

Present this 

card

2. 

 Wa

it for the required

 period 

3. 

 Present this 

card ag

ain, the 

beeping 

will stop

Paxton 

Access

FUNCTION CARD

door open time card

The period that the door

 is 

unlocked f

or when 

valid token is 

presented is 

set 

as 

follows:

1.  

Present this ca

rd

2. 

 Wa

it for the required peri

od 

3.  

Present this car

d again, the 

beeping will 

stop

FUNCTION CARD 

door open time card 

The period that the door is unlocked for when a  

valid token is presented is set as follows: 

1.  Present this card 

2.  Wait for the required period  

3.  Present this card again, the beeping will stop 

Silent operation

1. Take the silent operation function card from the starter pack.

2. Present the card to the reader. The reader will beep.

3. The reader is now in silent operation mode.

4. Present the card again to disable silent operation mode. The reader will beep twice.

BEEP! 

BEEP!

BEEP!

Paxton A

ccess

FUNCTION CARD

silent o

peration

Present

 this c

ard to silenc

e t

he b

eep

ing no

ises

made b

y the r

ea

der

.  P

resent

 this card a

gain t

re-ena

ble t

he b

eep

ing no

ises

Paxton A

ccess

FUNCTION CARD

silent o

peration

Present

 this c

ard to silenc

e t

he b

eep

ing no

ises

made b

y the r

ea

der

.  P

resent

 this card a

gain t

re-ena

ble t

he b

eep

ing no

ises

FUNCTION CARD 

silent operation 

Present this card to silence the beeping noises 

made by the reader.  Present this card again to  

re-enable the beeping noises 

Содержание Ins-30003 PROXIMITY P Series

Страница 1: ...Ins 30003 PROXIMITY P series compact reader ...

Страница 2: ...xton co uk support paxton co uk 01273 811011 Quickstart guide This supplement is a brief guide to installing a P series compact system Further information is available for download at http www paxton co uk or call the communications team on 01273 811011 Exit button push to make Electric release 12V DC power supply 12V DC release current rating must be less than 1A 0V 0V 0V 12V 12V Exit ...

Страница 3: ...he reset OR 1 Present Enrolment card 2 Present Door open time card twice 3 Present Enrolment card 4 Present Door open time card twice 5 WAIT FOR 5 SECONDS Wiring The unit should be mounted in conjunction with an electrical backbox to achieve the required clearance for the connector If an adaptor plate 310 750 is fitted the mountings on the backbox can also be used The reader s default indication h...

Страница 4: ...ader User cards Shadow cards BEEP BEEP 2 3 4 1 At ins tal lat ion pr es en t th is ca rd to th e re ad er to va lid ate th e to ke ns in th is pa ck 2 To re v ali da te a us er to ke n pr es en t th is en ro lm en t ca rd to th e re ad er fol low ed by th e us er to ke n Pa xto n Ac ce ss FUNCTION CARD enro lm ent card Mo re inf o ht tp pa xto n inf o 74 1 At ins tal lat ion pr es en t th is ca rd...

Страница 5: ... The reader will start beeping 3 Wait for the required period you wish the door to remain open 4 Present the card again at the end of the period to set the open time The beeping will stop 1 2 3 4 BEEP BEEP Pa xto n Ac ces s FUNCTIO N CARD door open tim e ca rd Th e pe rio d tha t the do or is un loc ke d for wh en a va lid tok en is pre sen ted is set as fol low s 1 Pre sen t thi s car d 2 Wa it f...

Страница 6: ...ack white grey blue and silver Registered installers can order these free of charge by logging onto the secure installer extranet http paxton info 1035 or if you are not a registered installer please call us on 01273 811011 for more information Fitting ...

Страница 7: ...age should be applied to the exit input wires Blue Mauve of a compact unit Most phone systems will provide a voltage pair to release the door lock this voltage must be used to drive an independent relay The relay contacts must be normally open going closed to mimic a push to make exit button Only if the output pair from the phone system is voltage free can this be connected directly to the exit in...

Страница 8: ...lf tapping screw zinc 3 Wall Plugs 1 Pozi pan self tapping screw small 5 Cable clips Switchable current Features Door open time Time zones with additional time clock Silent operation Can be used with fail OPEN locks Can be used with fail CLOSED locks Exit button input Door Contact input Number of Users Cable length Min Max Voltage Specifications Operating temperatures all items Electrical Environm...

Отзывы: