LIST OF THE MODBUS PROTOCOL HOLDING REGISTERS
Address Holding Register
R/W Notes
40001 Status Register
R
See relevant table.
40002 Gross weight (MSB)
R
FLOAT value.
40003 Gross weight (LSB)
R
FLOAT value.
40004 Net weight (MSB)
R
FLOAT value.
40005 Net weight (LSB)
R
FLOAT value.
40006 Peak (MSB)
R
FLOAT value.
40007 Peak (LSB)
R
FLOAT value
40008 Logic Inputs
R
Only DAT 100 ANA. It’s always 0 in the other versions.
40009 Logic Outputs
R/W Writing of outputs enabled only if the SET POINTs are
programmed to 0.
40201 SET POINT 1 (MSB)
R/W FLOAT value. Used only for DAT 100 ANA.
40202 SET POINT 1 (LSB)
R/W FLOAT value. Used only for DAT 100 ANA.
40203 SET POINT 2 (MSB)
R/W FLOAT value. Used only for DAT 100 ANA.
40204 SET POINT 2 (LSB)
R/W FLOAT value. Used only for DAT 100 ANA.
40501 Data Register (MSB)
W FLOAT value. Writing before or with the same query of
Command Register.
40502 Data Register (LSB)
W FLOAT value. Writing before or with the same query of
Command Register.
40503 Command Register
W See relevant table.
41001 Capacity of the load cells (MSB)
R/W
41002 Capacity of the load cells (LSB)
R/W
41003 Sensitivity of the load cells
R/W
41004 Weight division value
R/W See relevant table.
41101 Weight filter factor
R/W
41102 Weight stability factor
R/W
41103 Auto-zero SET POINT
R/W FLOAT value.
41104 Auto-zero SET POINT
R/W FLOAT value.
41105 Zero tracking factor
R/W
41106 Zero band
R/W
41107 Weight Delta
R/W
41201 Operation mode of the thersold 1 R/W See relevant table. Used only for DAT 100 ANA.
41202 Hysteresis of the SET POINT 1
R/W FLOAT value. Used only for DAT 100 ANA.
41203 Hysteresis of the SET POINT 1
R/W FLOAT value. Used only for DAT 100 ANA.
41204 Operation mode of the thersold 2 R/W See relevant table. Used only for DAT 100 ANA.
41205 Hysteresis of the SET POINT 2
R/W FLOAT value. Used only for DAT 100 ANA.
41206 Hysteresis of the SET POINT 2
R/W FLOAT value. Used only for DAT 100 ANA.
41401 Analog full scale (MSB)
R/W FLOAT value. Used only for DAT 100 ANA.
41402 Analog full scale (LSB)
R/W FLOAT value. Used only for DAT 100 ANA.
41403 Oper. mode Anal. Output
R/W 0 = net, 1 = gross, 2 = peak. Used only for DAT 100
ANA.
41404 Analog Output range
R/W 0 = 0-20 mA, 1 = 4-20 mA, 2 = 0-10 V, 3 = 0-5 V.
42000 Monitor register
W The programmed value is automatically copied to Monitor
Register (42100).
42100 Monitor register
R