Page 18
Otrac
TRACKING THE ZERO
This function allows a momentary zero calibration compensating the
eventual temperature drift of the weight.
At power off it automatically returns to the previous calibration.
The maximum weight resettable by this parameter is 2% of the range
of the system.
To disable this feature, use the value 0.
Value
Change
0
Control OFF
1
0.5 div/sec
2
1 div/sec
3
2 div/sec
4
3 div/sec
Default: 0
Oband
ZERO BAND
This parameter defines the number of divisions resettable by pressing
the zero front button.
Values: from 0 to 200
Default: 100
dELta
WEIGHT DELTA
It defines the minimum number of divisions needed to discriminate
two consecutive weighing in serial transmissions of the weight.
Values: from 0 to 200
Default: 20
Содержание DAT 100