Paul Agnew Ilektro 1250L Скачать руководство пользователя страница 27

27

REMOVING THE GLASS

USING TWO GLASS LIFTING SUCTION PADS
GRIP THE FRONT GLASS IN THESE LOCATIONS

RELEASING

 

THE

 

GLASS

WARNING:

 

ALTHOUGH

 

THE

 

GLASS

 

PANEL

 

HAS

 

BEEN

 

TREATED

 

WITH

 

SAFETY

 

EDGES

 

PLEASE

 

TAKE

 

CARE

 

WHEN

 

HANDLING

 

THE

 

GLASS.

 

AVOID

 

CONTACT

 

WITH

 

CORNERS

 

AND

 

IF

 

NECESSARY

 

WEAR

 

PROTECTIVE

 

GLOVES.

 

TWO

 

PEOPLE

 

MAY

 

BE

 

REQUIRED

 

TO

 

REMOVE

 

THE

 

GLASS.

THE GLASS IS HELD IN POSITION BY
CLAMPS. THE FRONT GLASS HAS 2
CLAMPS. WIDER MODELS HAVE 3

THE SIDE GLASS DOES NOT NEED TO
BE REMOVED AT ANY TIME UNLESS TO
REPLACE A DAMAGED GLASS WINDOW

BEGIN BY LOOSENING THE NUTS THAT
HOLD THE CLAMPS.

DO NOT REMOVE THE

NUTS FROM THEIR THREADS.

TAKING GREAT CARE, TAKE THE WEIGHT OF THE
GLASS AND ALLOW THE GLASS TO SLIP OFF
ITS SEAT AS SHOWN IN IMAGE A, AND LOWER
INTO THE CHANNEL IN FRONT OF THE CLAMP
THREADS, POSITION B. NOW LEAN THE GLASS
TOP EDGE OUT OF THE APPLIANCE.

ONCE THE CLAMPS ARE FREE FROM
TENSION WITH THE GLASS, LIFT THE
CLAMPS AWAY FROM THE APPLIANCE AND
SET ASIDE.

SERVICING

 

INSTRUCTIONS

 

1

5

. REMOVING

 

THE

 

GLASS

Содержание Ilektro 1250L

Страница 1: ...TH 230V 240V 50HZ ELECTRICITY SUPPLY ONLY PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THE INSTRUCTIONS IN A SAFE PLACE THEY WILL BE NEEDED WHEN MAINTENANCE OR SERVICING IS REQUIR...

Страница 2: ...TRE OR COLLECTION POINT YOU CAN FIND YOUR NEAREST RECYCLING CENTRE BY USING THE BANK LOCATOR AT WWW RECYCLE MORE CO UK FOR UK CUSTOMERS WWW ACOR ORG AU FOR AUSTRALIA CUSTOMERS WWW WEEEIRELAND IE FOR C...

Страница 3: ...FIREPLACE ENSURE THE APPLIANCE IS LEVEL AND THAT FURNITURE CURTAINS ETC ARE POSITIONED NO CLOSER THAN 1M WHEN THE APPLIANCE HAS BEEN INSTALLED THE POSITION OF THE PLUG MUST BE ACCESSIBLE OR AN ISOLAT...

Страница 4: ...PARTICULAR ATTENTION MUST BE GIVEN WHERE CHILDREN AND VULNERABLE PEOPLE ARE PRESENT CHILDREN AGED FROM 3 YEARS AND LESS THAN 8 YEARS SHALL ONLY SWITCH ON OFF THEAPPLIANCE PROVIDED THAT IT HAS BEEN PL...

Страница 5: ...EN IT WILL ASK YOU TO CREATE AN ACCOUNT OR LOG IN TO YOUR EXISTING ACCOUNT REGISTER WITH YOUR EMAIL ID OR MOBILE PHONE NUMBER AS THE USERNAME PUT ANY 6 TO 20 DIGIT NUMBERS AS PASSWORD AGREE TO THE TER...

Страница 6: ...OTH DEVICES ADD THE DEVICE BY PRESSING THE THEN ENTER THE WIFI PASSWORD FOR CONNECTING NOTE THE PHONE CAN ONLY CONNECT TO 2 4GHz WIFI AT THAT TIME CONNECTING SUCCESSFULLY THE FIREPLACE WILL DISPLAY P4...

Страница 7: ...STEP 1 TO STEP 4 FUNCTIONS LIGHT FUNCTIONS YOU CAN CHANGE THE COLOUR AND BRIGHTNESS OF THE FLAME YOU CAN CHANGE THE COLOUR OF FUEL BED YOU CAN CHANGE THE COLOUR OF THE DOWNLIGHT HOW TO USE YOUR APPLI...

Страница 8: ...ET THE TARGET TEMPERATURE THE FIRE WILL AUTOMATICALLY CONTROL ITS HEATER TO WARM YOUR ROOM TO THAT TEMPERATURE AND MAINTAIN IT AROUND THAT TEMPERATURE SOUND FUNCTION YOU CAN ADJUST THE VOLUME OF FIRE...

Страница 9: ...ROL THE FLAME PICTURE ONLY AT B ABOVE f IF YOU WOULD LIKE TO CONTROL YOUR FIRE FOR A SECOND PERIOD ON THE SAME DAY S THEN FOLLOW THE SAME PROCESS FOR PERIOD 2 g IT IS ESSENTIAL TO TOUCH THE CONFIRM BU...

Страница 10: ...STEP 01 STEP 02 STEP 03 STEP 04 STEP 05 STEP 06 10...

Страница 11: ...11 STEP 07 STEP 08 STEP 09...

Страница 12: ...LE 8 SOUND SETTINGS 3 SOUND SETTINGS 0 OFF THE SOUND 1 LOW SOUND 2 LOUD SOUND 9 SPEED OF FLAME 3 FLAME SPEED SETTINGS 1 LOW SPEED 2 INTERMEDIATE SPEED 3 HIGH SPEED 10 HEATING H0 HEATING OFF H1 LOW HEA...

Страница 13: ...NDERTAKING AND MAINTENANCE GENERAL CLEANING ONLY CLEAN THE GLASS WHEN ITS COLD DO NOT USE ABRASIVE CLEANERS ON ANY PART OF THE APPLIANCE USE A LINT FREE CLOTH TO WIPE ANY SURFACES DO NOT SPRAY CLEANER...

Страница 14: ...WHEN THE REMOTE BATTERIES IS LOW IT MUST BE CHANGED IMMEDIATELY INSTALL CORRECT REPLACEMENTS AND DISPOSE OF THE OLD BATTERIES CAREFULLY HOW TO USE YOUR APPLIANCE 5 MAINTENANCE AND CARE BATTERY REPLAC...

Страница 15: ...THE SPEC SHEET FOR YOUR APPLIANCE MODEL 950A 1250 L 1650L 2000L WEIGHT Kg 43 56 76 81 VOLTAGE 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz BATTERY HANDSET TRANSMITTER 12 V MN 21 23 12 V MN 21 23 12 V MN 2...

Страница 16: ...DAMAGE THE SURFACE OF THE APPLIANCE OR THE INSTALLATION AREA KEEP PLASTIC WRAPPING AWAY FROM CHILDREN BE RESPONSIBLE WHEN HANDLING THE PACKING MATERIALS CHECK ALL PARTSAND ACCESSORIES ARE REMOVED BEFO...

Страница 17: ...REWS USING THE CORRECT SCREWDRIVER RETAIN THE SCREWS FOR RE ASSEMBLY IF YOU ARE BUILDING THE APPLIANCE AS A BAY WINDOW REMOVE BOTH THE BLANKING PLATE AND THE SIDE TRIM REPLACE JUST THE BLANKING PLATE...

Страница 18: ...POWER CORD IS DAMAGED IT MUST BE REPAIRED BY THE MANUFACTURER ITS AUTHORIZED SERVICE CENTREOR PROFESSIONAL PERSON ENSURE THAT CURTAINS AND FURNITURE ARE NOT POSITIONED CLOSE TO THE CHOSEN POSITION AS...

Страница 19: ...THE BRACKETS AS SHOWN SO THEY ARE FLAT AGAINST THE FIXING WALL AND ALIGN WITH THE MOUNT HOLES ON YOUR APPLIANCE RETURN THE BRACKET SCREWS LOOSELY NOTE NO FIXTURES ARE SUPPLIED TO SECURE THE APPLIANCE...

Страница 20: ...NY OF THE MATERIAL TO DROP INTO THE APPLIANCE LOG INSTALLATION IS TO BE CARRIED OUT BY A QUALIFIED INSTALLATION TECHNICIAN OR FOLLOW THE INSTRUCTIONS IT IS RECOMMENDED TO RETURN THE FRONT TRIM WHILE I...

Страница 21: ...W TO INSTALL YOUR APPLIANCE 10 SETTING THE FUEL BED 950A LOG ARRANGEMENT 9 PIECE LOG SET 1250L LOG ARRANGEMENT 11 PIECE LOG SET 1650L LOG ARRANGEMENT 13 PIECE LOG SET 2000L LOG ARRANGEMENT 16 PIECE LO...

Страница 22: ...ONNECTED TO MAINS POWER CONNECTING TO MAINS SUPPLY CHECK WHETHER THE MAINS SUPPLY CAN ACCOMMODATE THE ADDITIONAL LOAD OF 1000 OR 2000 WATT CONNECT THE POWER CABLE TO AN EARTHED SOCKET ONLY USE THE POW...

Страница 23: ...LUBRICATION HOWEVER PERIODIC CLEANING VACUUM OF THE FAN HEATER UNIT IS RECOMMENDED RESETTING THE THERMAL CUT OUT SWITCH THE APPLIANCE IS FITTED WITH AN ELECTRONIC SAFETY CONTROL E S THIS ISA SAFETY DE...

Страница 24: ...TERIES IN YOUR HANDSET CHECK IF THEBATTERIES ARE IN THE CORRECT POSITION AND REFIT IF NECESSARY 5 IF AFTER CHECKING 1 2 3 4 NOTHING STILL HAS HAPPENED THEN DISCONNECT THE POWER FROM THE MAINS UNPLUG F...

Страница 25: ...ASS USE GLASS OR WINDOW CLEANER SERVICING INSTRUCTIONS 14 SERVICING REQUIREMENTS 1 TURN ON THE FLAME EFFECT BUTTON B B3 IF APPLIANCE DOES NOT WORK THEN FOLLOW THE FAULT FINDING GUIDE 2 CYCLE ALL BUTTO...

Страница 26: ...ESSARY IF REQUIRED PLEASE CONTACT YOUR DEALER FOR FURTHER SUPPORT CAUTION BROKEN GLASS CAN CAUSE SERIOUS INJURY TAKE EXTRA CARE WHEN HANDLING THE APPLIANCE WINDOW GLASS IS NOT UNDER WARRANTY DO NOT OP...

Страница 27: ...HAS 2 CLAMPS WIDER MODELS HAVE 3 THE SIDE GLASS DOES NOT NEED TO BE REMOVED AT ANY TIME UNLESS TO REPLACE A DAMAGED GLASS WINDOW BEGIN BY LOOSENING THE NUTS THAT HOLD THE CLAMPS DO NOT REMOVE THE NUTS...

Страница 28: ...iLEKTRO 950A LED LED LED NTC MOTOR FAN MOTOR HEATING ELEMENT HEATING ELEMENT PCB FAN MOTOR 288 REFERENCE INFORMATION 16 WIRING DIAGRAM...

Страница 29: ...LED LED LED LED LED LED LED LED LED NTC MOTOR FAN MOTOR HEATING ELEMENT HEATING ELEMENT PCB FAN MOTOR iLEKTRO 1250L 2 9 REFERENCE INFORMATION 16 WIRING DIAGRAM 29...

Страница 30: ...LED LED LED LED LED LED LED NTC MOTOR FAN MOTOR HEATING ELEMENT HEATING ELEMENT PCB FAN MOTOR LED LED iLEKTRO 1650L 30 REFERENCE INFORMATION 16 WIRING DIAGRAM...

Страница 31: ...LED LED LED LED NTC MOTOR FAN MOTOR HEATING ELEMENT HEATING ELEMENT PCB FAN MOTOR RGB 270mm RGB 270mm iLEKTRO 2000L 311 REFERENCE INFORMATION 16 WIRING DIAGRAM...

Страница 32: ...322 950A EXPLODED DIAGRAM REFERENCE INFORMATION 17 EXPLODED DIAGRAM...

Страница 33: ...02830236 Trumpet driving board 1 26 100422930125 Air flue upper board 1 78 440402860000 Receiver 1 27 100422932000 Air flue left board 1 79 450002070100 Heating element 2 28 100422932015 Air duct baff...

Страница 34: ...1250L EXPLODED DIAGRAM 344 REFERENCE INFORMATION 17 EXPLODED DIAGRAM...

Страница 35: ...355...

Страница 36: ...1650L EXPLODED DIAGRAM 366 REFERENCE INFORMATION 17 EXPLODED DIAGRAM...

Страница 37: ...440402830125 Main control board 1 27 100422930125 Air flue upper board 1 81 440402830236 Trumpet driving board 1 28 100422932000 Air flue left board 1 82 440402860000 Receiver 1 29 100422932015 Air d...

Страница 38: ...2000L EXPLODED DIAGRAM 38 REFERENCE INFORMATION 17 EXPLODED DIAGRAM...

Страница 39: ...ol board 1 27 100422920125 Stepping motor bracket 2 82 440402830236 Trumpet driving board 1 28 100422930125 Air flue upper board 1 83 440402860000 Receiver 1 29 100422932000 Air flue left board 1 84 4...

Страница 40: ...orabbin Victoria 3189 www paulagnewdesigns com au info paulagnewdesigns com au EUROSTOVE LTD Unit H1 Mendip Industrial Estate Mendip road Rooksbridge Somerset BS26 2UG www eurostove co uk sales eurost...

Отзывы: